• Title/Summary/Keyword: effect of SDS

Search Result 525, Processing Time 0.026 seconds

Effect of Salinity on Mechanical Characteristics of Stabilized Dredged Soil (고화준설토의 역학적 특성에 대한 염분의 영향)

  • Kim, Yun-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.9
    • /
    • pp.47-53
    • /
    • 2011
  • Marine dredged soils taken from navigation channels or construction sites of coastal area usually have a lot of salt in pores of clayey soils. This paper investigates effect of salt on mechanical characteristics of non-salt and salt-rich stabilized dredged soil. The stabilized dredged soil (SDS) consisted of dredged soil and cement. Several pairs of SDS with non-salt and salt-rich dredged soils, noted as N-SDS and S-SDS, respectively, were prepared to compare their strengths and compressibility characteristics. The microstructures, strength and compressibility characteristics of N-SDS and S-SDS specimens at 7 and 28 days of curing time were evaluated using scanning electronic microscope (SEM), unconfined compression test, and oedometer test. It was found that salt concentration of clayey soil affected not only the formation of soil structure but also the strength development of mixture. The compression index and swelling index of S-SDS were also greater than those of N-SDS, which indicated that the compressibility of mixture increased due to salt concentration. Salinity in clayey soil had a negative effect on the strength development and compressibility characteristics of stabilized dredged soils.

Effect of SDS on Retention of Nucleic Acid Components in High-Performance Liquid Chromatography

  • Kim Yong-Nam;Choi Kyeung-Soo;Lee Dai-Woon;Phyllis R. Brown
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.3
    • /
    • pp.240-245
    • /
    • 1992
  • The effect of the addition of sodium dodecyl sulfate (SDS) to a buffered mobile phase (pH 3.4) on the retention of nucleotides, nucleosides and bases was investigated with a polyvinyl alcohol (PVA) column. Depending on the concentration of SDS, two different trends in the retention of nucleosides and bases containing an $NH_2$ group were observed. If the concentration of SDS was less than 5.5 mM, the retention of compounds containing an $NH_2$ group increased as the concentration of SDS in the mobile phase increased. In contrast, if the concentration was greater than 5.5 mM, the retention of compounds containing an $NH_2$ group decreased. Thus, the SDS acted as an ion-pairing reagent at lower concentration but formed micelles at higher concentrations. The retention behavior of the nucleosides and bases in the presence of a micellar concentration of SDS in the mobile phase on the PVA column was compared to the retention behavior on other types of columns.

Inhibition of Human Hemoglobin Autoxidaiton by Sodium n-Dodecyl Sulphate

  • Reza, Dayer Mohammad;Ali Akbar, Moosavi-Movahedi;Parviz, Norouzi;Ghourchian, Ghourchian;Hedayat-Olah, Hedayat-Olah;Shahrokh, Safarian
    • BMB Reports
    • /
    • v.35 no.4
    • /
    • pp.364-370
    • /
    • 2002
  • The effect of sodium n-dodecyl sulphate (SDS) on hemoglobin autoxidation was studied in the presence of a 100mM phosphate buffer (pH 7.0) by different methods. These included spectorphotometry, fluorescence technique, cyclic voltametry, differential scanning calorimetry, and densitometry. Spectroscopic studies showed that SDS concentrations up to 1 mM increased deoxy-, decreases oxy-, and had no significant effect on the met- conformation of hemoglobin. Therefore, a SDS concentration up to 1 mM increased the deoxy form of hemoglobin as the folded, compact state and decreases the oxy conformation. The turbidity measurements and differential scanning calorimetry techniques indicated a more stable conformation for hemoglobin in the presence of SDS up to 1mM. Electrochemical studies also confirmed a more difficult oxidation under these conditions. The induction of the deoxy form in the presence of SDS was confirmed by densitometry techniques. The compact structure of deoxyhemoglobin blocks the formation of met-conformation in low SDS concentrations.

Aggregation and Dissolution of Cationic Dyes with an Anionic Surfactant

  • Park, Joon-Woo;Chung, He-SSon
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.113-116
    • /
    • 1986
  • Spectral behaviors of cationic dyes, methylene blue(MB) and acridine orange(AO), with varying concentrations of sodium dodecylsulfate(SDS) were studied. At low concentration of SDS(<1mM), these dyes formed insoluble dye-surfactant aggregates. When [SDS] is 4-5 mM, the aggregates were dissolved into mixed micelles of constant composition. At higher concentration of [SDS], the composition of mixed micelles were changed with [SDS], resulting only monomeric form of dyes in micelles. AO-SDS system showed greater aggregating and less dissolving properties, and weaker effect of salt than MB-SDS system did. These were attributed to the greater hydrophobic nature of the former dye. The monomer/dimer ratios of dyes in mixed micelles at given [SDS] were greatest at $20^{\circ}C$, reflecting the dependency of CMC of the surfactant on temperature.

Electrochemical Investigation of Bovine Hemoglobin at an Acetylene Black Paste Electrode in the Presence of Sodium Dodecyl Sulfate

  • Zhan, Guoqing;Li, Chunya;Luo, Dengbai
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1720-1724
    • /
    • 2007
  • Electrochemical behaviors of bovine hemoglobin (Hb) at an acetylene black paste electrode based on the enhancement effect of sodium dodecyl sulfate (SDS) were investigated. In the optimal conditions, a very weak reduction peak was observed at an acetylene black paste electrode for hemoglobin in the absence of SDS. However, the reduction peak current increased remarkably after the addition of 4.0 × 10?4 mol L?1 SDS, suggesting that SDS exhibits obvious enhancement effect to the determination of hemoglobin. All the experimental parameters, such as pH value, concentration of SDS, accumulation time and accumulation potential were optimized for hemoglobin analysis. The proposed method possesses high sensitivity (detection limit is 3.0 × 10?9 mol L?1), wide linearity (6.0 × 10?9 to 6.0 × 10?7 mol L?1), rapid response and low cost. Finally, the method was successfully employed to determine hemoglobin in a spiked sample.

Effect of Surfactant on Rheological and Electrical Properties of Latex-Blended Polystyrene/Single-Walled Carbon Nanotube Nanocomposites (계면활성제가 라텍스 블렌딩 폴리스티렌/단일벽 탄소나노튜브 나노복합재료의 유변학적, 전기적 물성에 미치는 영향)

  • Kang, Myung-Hwan;Noh, Won-Jin;Woo, Dong-Kyun;Lee, Seong-Jae
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.364-371
    • /
    • 2012
  • Polystyrene/single-walled carbon nanotube (PS/SWCNT) nanocomposites were prepared by latex technology and the effect of surfactant (SDS) on nanotube dispersion, rheological and electrical properties was investigated. The nanocomposites were prepared through freeze-drying after mixing PS particles and aqueous SWCNT/SDS suspension. As the SDS content increased, the storage modulus and complex viscosity of the nanocomposites were increased due to enhanced dispersion of nanotubes, but if the content excessively increased, the modulus and viscosity began to decrease due to low molecular weight of SDS. The electrical conductivity sharply increased with the addition of SDS, and then did not show significant changes. This result is speculated to be the competition between the increased dispersion of nanotubes and the deterioration of electrical conductivity by SDS adsorption. An optimal ratio of SDS to SWCNT for improving electrical conductivity and end-use properties was 2. With this ratio, the electrical percolation threshold of SWCNT was less than 1 wt%.

Effect of n-Butanol on the Mixed Micellar Properties of Sodium Dodecylsulfate(SDS) with Sodium Dodecylbenzenesulfonate(DBS) (Sodium Dodecylsulfate(SDS)와 Sodium Dodecylbenzenesulfonate(DBS)의 혼합미셀화에 미치는 n-Butanol의 효과)

  • 이병환
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.1
    • /
    • pp.12-17
    • /
    • 1997
  • The critical micelle concentrations(CMC*) and the counterion binding constants(B) in a micellar state of the mixed surfactant systems of sodium dodecylsulfate(SDS) with sodium dodecylbenzenesulfonate(DBS) at 25℃ in pure water and in aqueous solutions of n-butanol were determined as a function of α1 (the overall mole fraction of SDS) by the use of electric conductivity method. Various thermodynamic parameters(Xi, γi, Ci, aiM, β, ΔHmix and ΔGm0 for the micellization of SDS/DBS mixtures were calculated and analyzed by means of the equations derived from the nonideal mixed micelle model. The effect of n-butanol on the mixed micellization of SDS/DBS mixtures have been measured and analyzed by comparing the values of the thermodynamic parameters in pure water with those in aqueous solutions of n-butanol(0.1 M, 0.2 M, and 0.3 M).

  • PDF

Analgesic Effect of Electroacupuncture after Femoral Head Osteotomy in Dogs (개에서 대퇴골두 제거술 후 전침 자극이 통증완화에 미치는 영향)

  • Choi In-young;Cheong Jongtae;Shin Taekyun;Lee Joo-myoung
    • Journal of Veterinary Clinics
    • /
    • v.21 no.4
    • /
    • pp.374-397
    • /
    • 2004
  • This experiment was designed to investigate the analgesic effect of non-invasive electroacupuncture treatment on femoral head osteotomy in dogs. Twelve dogs were divided into 3 groups in this experiment. Electroacupuncture group was non-invasively electrostimulated in Huan Tiao (GB-30) acupoint for 10 minutes by 4.5V, 5Hz for 10 days. Medication group was treated with carprofen (4mg/kg, P.O.) for 10 days. Control group was not treated. Each group was pre-operatively and post-operatively scored by using VAS (Visual Analogue Scale), SDS (Simple Descriptive Scale), NRS (Numerical Rating Scale), and measured serum cortisol levels. The results of VAS, SDS and NRS in electroacupuncture and medication groups were better than those of control group. And, the results of electroacupuncture group were better than those of medication group since 6th day after osteotomy in pain management(p<0.05). But, there were no significances in serum cortisol level among 3 groups. In conclusion, non-invasive electroacupuncture treatment showed sufficient analgesic effect on postoperative pain management after femoral head osteotomy, and VAS, SDS, and NRS scoring system would be adapted in evaluation of pain management.

Study on the Effect of the SDS on the Behavior of Anionic Surfactants in Electrophoresis (전기영동에서 SDS가 음이온 계면활성제의 거동에 미치는 영향에 대한 고찰)

  • Lee, Ji-Eun;Lee, Myeong-Sok;Jeong, Hyuk
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.356-363
    • /
    • 2001
  • A basic study of the effect of the SDS on the behavior of the anionic surfact in electrophoresis was performed. Having been interacted with SDS micelle, long chain carboxylates and sulfonates which have more than 10 carbons have been suffered larger changes in their apparent mobilities. Based on the result of the comparison among apparent, electroosmotic and electrophoretic mobilities, it is demonstrated that the major cause for the variation of the apparent mobilities of the anions is the variation of the electrophoretic mobilities.

  • PDF

Effect of Molecular Weight of Chitosan on Flocculation of Suspended Solids in Rhodamine 6G-Sodium Dodecyl Sulfate System (키토산 분자량에 따른 Rhodamine 6G-Sodium Dodecyl Sulfate계의 응집효과에 관한 연구)

  • Kim, Sung Hyun;Nah, Jae Woon;Oh, Jeong Sun;Song, Ki Dong
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.672-678
    • /
    • 1998
  • Chitin was extracted from crab shell of Portuns triberculatus and deacethylated to yield chitosan with various molecular weights. The absorption and the fluorescence spectra of Rhodamine 6G(Rh 6G)-sodium dodecyl sulfate(SDS) and Rh 6G-chitosan systems were obtained. From the spectra, we observed that the absorption and the fluorescence intensity of Rh 6G-SDS system decreased when S/D(the concentration of SDS to that of Rh 6G ratio) was below or at 32, while they increased when S/D was above 32. From the suspended solid(SS) removal rate and the transmittance of Rh 6G-SDS-chitosan system, we found that when S/D ratio was 32 its flocculating behaviour was much stronger than Rh 6G-SDS system. As the concentration and the molecular weight of chitosan increased, we also found that S/D range was extended from 32 to 100. With increasing the molecular weight of chitosan, the SS removal rate increased around pH 2~9 but decreased remarkably at pH>12.

  • PDF