• Title/Summary/Keyword: edentulous

Search Result 697, Processing Time 0.036 seconds

Evaluation of reliability of zirconia materials to be used in implant-retained restoration on the atrophic bone of the posterior maxilla: A finite element study

  • Degirmenci, Kubra;Kocak-Buyukdere, Ayse;Ekici, Bulent
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.112-119
    • /
    • 2019
  • PURPOSE. Zirconia materials have been used for implant-retained restorations, but the stress distribution of zirconia is not entirely clear. The aim of this study is to evaluate the stress distribution and risky areas caused by the different design of zirconia restorations on the atrophic bone of the posterior maxilla. MATERIALS AND METHODS. An edentulous D4-type bone model was prepared from radiography of an atrophic posterior maxilla. Monolithic zirconia and zirconia-fused porcelain implant-retained restorations were designed as splinted or non-splinted. 300-N occlusal forces were applied obliquely. Stress analyses were performed using a 3D FEA program. RESULTS. According to stress analysis, the bone between the 1) molar implant and the 2) premolar in the non-splinted monolithic zirconia restoration model was stated as the riskiest area. Similarly, the maximum von Mises stress value was detected on the bone of the non-splinted monolithic zirconia models. CONCLUSION. Splinting of implant-retained restorations can be more critical for monolithic zirconia than zirconia fused to porcelain for the longevity of the bone.

Technique for fabricating a mandibular suction denture with a plastic implant tray (임플란트용 플라스틱 트레이를 이용하여 하악 흡착의치를 제작하는 방법)

  • Lee, Ju-Hyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.36-42
    • /
    • 2021
  • Even though implant overdentures are preferentially recommended to mandibular edentulous patients, many patients may select conventional complete dentures due to cost and general condition. Proper retention and stability of conventional complete dentures in patients with severe alveolar bone resorption is difficult to achieve. To overcome the limitations, mandibular suction dentures with the closed mouth impression technique have been used. However, the previous technique requires the Frame cut back tray, the Centric tray, and the Gnathometer M. This article introduces a technique for fabricating a mandibular suction denture with common dental materials.

A Study on the Performance of Dynamic Restraint Manipulator for Drilling Alveolar Bone in Mandible (하악골의 치조골 골삭제를 위한 동적 제약 기구부의 성능에 관한 연구)

  • Kim, Gwang-Ho;Lee, Dong-Woon;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.105-112
    • /
    • 2020
  • The increase in the edentulous jaw which occurs in the aged population has led to personal dental health concerns. In the case of dental implant surgery, the duration of a patient's recovery depends on the surgical plan and their physicical ability. A device may be required to assist a physician in controlling vibration reduction of free-hand drilling and prescribing a good treatment plan that is suitable for the patient's condition. In this work, an artificial tooth-root implant assistant manipulator was studied. The structure and the vibration analysis of the dynamic restraint manipulator that is for drilling the alveolar bone in the mandible bone were performed, and the structural stability was analyzed. Further, a virtual prototype of an artificial tooth-root implant assisted manipulator was fabricated and tested. Hence, the state of the Remote Center of Motion (RCM) point and the driving state of the manipulator were confirmed. Furthermore, the drilling experiments were performed by using materials similar to a human jawbone in order to evaluate the performance of the drilling process that is operated using the assistant manipulator.

Cr-Co removable partial denture treatment fabricated by selective laser melting: a case report (Selective Laser Melting을 이용한 코발트-크롬 가철성 국소의치의 수복 증례)

  • Yim, Ji-Hun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.39-47
    • /
    • 2021
  • Compared to conventional method, if metal framework of removable partial denture is fabricated by selective laser melting, various laboratory works are omitted, saving time and simplifying the process. In addition, metal framework with homogeneous density can be obtained, expecting excellent mechanical properties, especially resistance to fatigue fracture. In these cases, impression were taken using conventional methods in partial edentulous patients, master casts were fabricated and scanned to obtain digital data. After designing the metal frameworks on the scanned data, removable partial dentures were fabricated using selective laser melting methods. Through these procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Recurrent benign cementoblastoma: A case report and literature review

  • Yoon, Yeong-Ah;Kwon, Young-Eun;Choi, So-Young;Choi, Karp-Shik;An, Seo-Young;An, Chang-Hyeon
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.447-454
    • /
    • 2021
  • A 16-year-old male presented with pain in the right posterior mandible on chewing that had lasted for several months. The radiographic features of the lesion included a radiolucent-radiopaque mixed-density mass with a radiolucent rim attached to the root of the mandibular right first molar. The preliminary radiographic diagnosis was benign cementoblastoma, which was confirmed by histopathological examination following surgical excision. The lesion recurred 3 years after treatment; radiographically, it consisted of 3 round foci with mixed radiopacity, each with a radiolucent rim near the root of the mandibular right second premolar and the edentulous postoperative region. The lesion was diagnosed as recurrent benign cementoblastoma and a second surgery was scheduled. This report presented an unusual case of recurrent benign cementoblastoma following surgical excision and extraction of the involved tooth, along with a literature review on reported cases of recurrent benign cementoblastoma with a focus on its clinical features and the best treatment options.

Accuracy of 14 intraoral scanners for the All-on-4 treatment concept: a comparative in vitro study

  • Gozde, Kaya;Caglar, Bilmenoglu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.388-398
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the accuracy of 14 different intraoral scanners for the All-on-4 treatment concept. MATERIALS AND METHODS. Four implants were placed in regions 13, 16, 23, and 26 of an edentulous maxillary model that was poured with scannable Type 4 gypsum to imitate the All-on-4 concept. The cast was scanned 10 times for each of 14 intraoral scanners (Primescan, iTero 2, iTero 5D, Virtuo Vivo, Trios 3, Trios 4, CS3600, CS3700, Emerald, Emerald S, Medit i500, BenQ BIS-I, Heron IOS, and Aadva IOS 100P) after the polyether ether ketone scanbody was placed. For the control group, the gypsum model was scanned 10 times with an industrial scanner. The first of the 10 virtual models obtained from the industrial model was chosen as the reference model. For trueness, the data of the 14 dental scanners were superimposed with the reference model; for precision, the data of all 14 scanners were superimposed within the groups. Statistical analyses were performed using the Kolmogorov-Smirnov, Shapiro-Wilks, and Dunn's tests. RESULTS. Primescan showed the highest trueness and precision values (P < .005), followed by the iTero 5D scanner (P < .005). CONCLUSION. Some of these digital scanners can be used to make impressions within the All-on-4 concept. However, the possibility of data loss due to artifacts, reflections, and the inability to combine the data should be considered.

Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study

  • Mirac Berke Topcu, Ersoz;Emre, Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.346-359
    • /
    • 2022
  • PURPOSE. Four and six implant-supported fixed full-arch prostheses with various framework materials were assessed under different loading conditions. MATERIALS AND METHODS. In the edentulous maxilla, the implants were positioned in a configuration of four to six implant modalities. CoCr, Ti, ZrO2, and PEEK materials were used to produce the prosthetic structure. Using finite element stress analysis, the first molar was subjected to a 200 N axial and 45° oblique force. Stresses were measured on the bone, implants, abutment screw, abutment, and prosthetic screw. The Von Mises, maximum, and minimum principal stress values were calculated and compared. RESULTS. The maximum and minimum principal stresses in bone were determined as CoCr < ZrO2 < Ti < PEEK. The Von Mises stresses on the implant, implant screw, abutment, and prosthetic screws were determined as CoCr < ZrO2 < Ti < PEEK. The highest Von Mises stress was 9584.4 Mpa in PEEK material on the prosthetic screw under 4 implant-oblique loading. The highest maximum principal stress value in bone was found to be 120.89 Mpa, for PEEK in 4 implant-oblique loading. CONCLUSION. For four and six implant-supported structures, and depending on the loading condition, the system accumulated different stresses. The distribution of stress was reduced in materials with a high elastic modulus. When choosing materials for implant-supported fixed prostheses, it is essential to consider both the number of implants and the mechanical and physical attributes of the framework material.

The Relationship Between Chewing Ability and Health Status in the Long-lived Elderly of Kyungpook Area (경북지역 장수노인의 저작능력과 건강상태)

  • Lee, Hee-Kyung;Lee, Young-Kwon
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.200-207
    • /
    • 1999
  • Background: The objective of this study is to evaluate the effect of the dental and general health in relation to the state of dentition and chewing ability by surveying oral condition and anthropometric measure in order to provide primary statistics for the development of a program which may lead to an improvement in the long-lived elderly health status in a rural community. Materials and Methods: The subjects of this study were 97 rural long-lived elderly(27 males and 70 females) who were over 85 years-old (average age of subjects are $88.14{\pm}3.20$ year old) in Sungju-Gun, Kyungpook Province. Data were collected by using questionnaires and direct measurement of anthropometrics, and oral examination from all 97 subjects on July, 1999. Results: The following results were obtained: 1. 53.6% of all subjects believe that they are healthy. The average values of height, weight, BMI, body fat, lean body fat and total water were $148.8{\pm}11.2cm$, $46.9{\pm}10.5kg$, $21.2{\pm}3.5kg/m^2$, $26.7{\pm}6.9%$, $73.0{\pm}7.1%$, and $53.4{\pm}5.2%$, respectively. 2. The average number of teeth remaining in the subjects were $3.50{\pm}5.71$; the number of maxillary teeth remaining were $1.08{\pm}2.88$; and the number of mandibular teeth remaining were $2.41{\pm}3.76$. The maximum number of teeth remaining among subjects were 22 teeth, and the fully edentulous(no natural teeth) people were 76.3%. The oral conditions of the subjects were 52.6% using denture, 23.7% using natural teeth, and 23.7% masticating edentulous ridge without denture. 3. In terms of oral condition in self-assessment of health, digestive ability, and chewing ability ; On self-assessment of health, 47.1% of those wearing denture group responded as feeling good, 56.5% of those in the group of edentulous without denture, and 65.2% in group of natural teeth only. On self-assessment of digestive ability, 82.4% of those in group of denture responded as feeling good, 65.2% of those in group of no teeth and no denture, and 73.9% of those in group of natural teeth only. On self-assessment of chewing ability, 90.2% of those in the group wearing a denture, 60. 9% of those in the group of no teeth and no denture, and 65.2% of those in the group of natural teeth only. 4. In terms of oral condition in anthropometric measurements; The height, weight, body fat, lean body mass, and total water according to oral conditions were $150.0{\pm}10.7cm$, $49.0{\pm}10.9kg$, $26.9{\pm}6.6%$, $72.7{\pm}7.0%$, $53.2{\pm}5.1%$, respectively, in group wearing a denture, $142.7{\pm}6.0cm$, $43.2{\pm}5.5kg$, $29.5{\pm}7.2%$, $70.8{\pm}6.9%$, $51.8{\pm}5.0%$, respectively, in the group of no teeth and no denture, and $152.3{\pm}14.1cm$, $45.9{\pm}12.6kg$, $23.4{\pm}6.0%$, $75.9{\pm}6.9%$, $55.6{\pm}5.1%$, respectively, in the group of natural teeth only. Conclusion: The subjective measurements of good health were higher denture user, and natural teeth.

  • PDF

The use of surgical guide stent for implant placement (임플란트 식립을 위한 수술 가이드의 사용)

  • Lee, Ji-Yeon;Yoon, Ji-Young;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.366-375
    • /
    • 2014
  • Surgical guide not only provide diagnosis and treatment plan, but even location and direction of implantation. Surgical guide could be divided into non-limited design, partially limited design, and completely limited design. Partially limited design is easily manufactured and inexpensive but less accuracy, compared to completely limited design. From this approach, partially limited design may be particularly effective in patients who present with a single missing tooth or partially edentulous teeth. Completely limited design is anatomically accuracy, esthetical and functional, optimized treatment for prosthetic and biomechanical perspective, and also minimizes discomfort for post-treatment. The purpose of this study is to review previous studies of various surgical guides and applying in clinic.

Mandibular Implant-Retained Overdenture: A Case Report (임플랜트지지 피개의치를 이용한 무치악환자의 구강회복)

  • Lee, Hong-Seok;Song, Kwang-Yeob;Kim, Ja-Young;Lee, Jung-Jun;Park, Ju-Mi;Ahn, Seung-Geun;Park, Charn-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.91-104
    • /
    • 2008
  • Recently, osseointegrated implants have been used to improve denture support, stability, and retention. Several studies have been revealed that mandibular two-implant overdentures significantly increase patient satisfaction with the function of their prostheses. Use of a wide variety of attachment systems, including stud, magnet, and bar attachments, has proven both clinically predictable and effective. This article presents that two-implant overdenture can become the standard of care for treatment of the edentulous mandible.