• 제목/요약/키워드: edentulous

검색결과 697건 처리시간 0.029초

전방 분절골 절단술과 임프란트 식립을 이용한 구강악기능의 재건 : 증례보고 (ORAL REHABILITATION WITH MANDIBULAR ANTERIOR SEGMENTAL OSTEOTOMY AND IMPLANTATION: A CASE REPORT)

  • 문철웅;김수관;김학균;문성용;유재식
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권4호
    • /
    • pp.319-324
    • /
    • 2009
  • Kole's Anterior segmental osteotomy of the mandible is commonly used to close an anterior open bite, to depress an elevated anterior dentoalveolar segment, or to retrude or advance a dentoalveolar segment. The procedure is often combined with an anterior maxillary segmental osteotomy to correct bimaxillary protrusion. We report 53-year-old woman who the extruded state of mandibular anterior alveolar segment was corrected using an mandibular anterior alveolar segmental osteotomy and dental implantation of the anterior maxilla. We planned to remove the old prosthesis, and then perform an anterior mandibular segmental osteotomy and implant restoration of the anterior maxilla. We suggest that anterior segmental osteotomy is very useful for rehabilitating edentulous patients with malaligned alveolar segment.

Displacement of dental implants into the focal osteoporotic bone marrow defect: a report of three cases

  • Lee, Sang-Chil;Jeong, Chang-Hwa;Im, Ho-Yong;Kim, Seong-Young;Ryu, Jae-Young;Yeom, Hak-Yeol;Kim, Hyeon-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권2호
    • /
    • pp.94-99
    • /
    • 2013
  • Focal osteoporotic bone marrow defect (FOBMD) is a radiolucent area corresponding to the presence of hematopoietic tissue rarely found in the jaws. FOBMD is most commonly located in the mandibular edentulous posterior area of a middle-aged female. From November 2011 to November 2012, we experienced three cases involving removal of implants that had accidentally fallen into the FOBMD area. All patients happened to be female, with a mean age of 54 years (range: 51-60 years). One case involved hypoesthesia of the lower lip and chin, while two cases healed without any complication. Displacement of an implant into the FOBMD area is an unusual event, which occurs rarely during placement of a dental fixture. The purpose of this study was to report on three cases of FOBMD and to provide a review of related literature.

구순구개열로 인한 심한 중안면부 성장부전환자에서 골신장술의 치험례 (DISTRACTION OSTEOGENESIS IN CASE OF CLEFT LIP AND PALATE PATIENT WITH SEVERE MAXILLARY DEFICIENCY)

  • 이백수;오정환;윤병욱;송상헌;류동목
    • 대한구순구개열학회지
    • /
    • 제6권2호
    • /
    • pp.131-135
    • /
    • 2003
  • Severe maxilla1y deficiency can be caused by cleft lip and palate(CLP), other craniofacial deformities, atrophy in the edentulous maxilla, and trauma. Patients with maxillary deficiency present a difficult treatment challenge. Traditionally, this skeletal deformity has been treated by Le Fort osteotomy, skeletal repositioning, and fixation with mini-plates and screws. The drawbacks of this method include a limited amount of anterior maxillary advancement often requiring simultaneous mandibular setback, the inability to create new bone, and minimal soft tissue adaptation to the new position, all of which increase the potential of relapse in case of large advancement. The alternative method of maxillary distraction osteogenesis offers promising results for successfully treatment of these patients while potentially minimizing the risk of relapse.

  • PDF

The influence of saliva pH value on the retention and durability of bar-clip attachments

  • Silva, Antonio Sergio;Aroso, Carlos;Ustrell, Raul;Braga, Ana Cristina;Mendes, Jose Manuel;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.32-38
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS. Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/pH 4) at $37^{\circ}C$ for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS. The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION. More acidic pH values were found to have a negative influence on the retention capacity of the attachments.

The path of placement of a removable partial denture: a microscope based approach to survey and design

  • Mamoun, John Sami
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.76-84
    • /
    • 2015
  • This article reviews the topic of how to identify and develop a removable partial denture (RPD) path of placement, and provides a literature review of the concept of the RPD path of placement, also known as the path of insertion. An optimal RPD path of placement, guided by mutually parallel guide planes, ensures that the RPD flanges fit intimately over edentulous ridge structures and that the framework fits intimately with guide plane surfaces, which prevents food collecting empty spaces between the intaglio surface of the framework and intraoral surfaces, and ensures that RPD clasps engage adequate numbers of tooth undercuts to ensure RPD retention. The article covers topics such as the causes of obstructions to RPD intra-oral seating, the causes of food collecting empty spaces that may exist around an RPD, and how to identify if a guide plane is parallel with the projected RPD path of placement. The article presents a method of using a surgical operating microscope, or high magnification (6-8x or greater) binocular surgical loupes telescopes, combined with co-axial illumination, to identify a preliminary path of placement for an arch. This preliminary path of placement concept may help to guide a dentist or a dental laboratory technician when surveying a master cast of the arch to develop an RPD path of placement, or in verifying that intra-oral contouring has aligned teeth surfaces optimally with the RPD path of placement. In dentistry, a well-fitting RPD reduces long-term periodontal or structural damage to abutment teeth.

Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

  • Al-Fouzan, Afnan F.;Al-mejrad, Lamya A.;Albarrag, Ahmed M.
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.402-408
    • /
    • 2017
  • PURPOSE. The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION. The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복 (Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown)

  • 김유리;오상천
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

TG Osseotite 임플란트의 성공률에 대한 임상적 연구 (CLINICAL STUDY ON SUCCESS RATE OF TG OSSEOTITE IMPLANT)

  • 오승환;민승기;채영원
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권1호
    • /
    • pp.39-47
    • /
    • 2005
  • The purpose of this study is to review the prognosis of the TG Osseotite implant(3i Co, USA) placed in partial edentulous area of oral cavity and to suspect the possible causes leading to failure. 124 TG Osseotite implants that had been inserted between 2000 - 2002 were followed up for 2 years(avg : 9.5 months) in function. Medical records, and radiographs were evaluated and analyzed by the over all success rate, gender and age factor, general disease, implant fixture length and diameter, implant site, bone density, and various surgical methods. Chi square test was used statistically. Of the 124 TG Osseotite implants, 9 implants(7.3%) were removed in early phase and 3 implants(2.4%) were in late phase. The cumulative survival rate was 90.2%. The failure of the TG Osseotite implant was closely related with the use of bone graft techniques such as sinus elevation or immediate implantation and not with the age, sex, general disease, implant site, bone density of implanted site. The failure of the TG Osseotite implant was well developed when it was the wide type of implant and it was inserted for single tooth replacement. The developement of peri-implantitis was the most important factor in the failure of the TG Osseotite implant.

Accuracy of the Point-Based Image Registration Method in Integrating Radiographic and Optical Scan Images: A Pilot Study

  • Mai, Hai Yen;Lee, Du-Hyeong
    • Journal of Korean Dental Science
    • /
    • 제13권1호
    • /
    • pp.28-34
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the influence of different implant computer software on the accuracy of image registration between radiographic and optical scan data. Materials and Methods: Cone-beam computed tomography and optical scan data of a partially edentulous jaw were collected and transferred to three different computer softwares: Blue Sky Plan (Blue Sky Bio), Implant Studio (3M Shape), and Geomagic DesignX (3D systems). In each software, the two image sets were aligned using a point-based automatic image registration algorithm. Image matching error was evaluated by measuring the linear discrepancies between the two images at the anterior and posterior area in the direction of the x-, y-, and z-axes. Kruskal-Wallis test and a post hoc Mann-Whitney U-test with Bonferroni correction were used for statistical analyses. The significance level was set at 0.05. Result: Overall discrepancy values ranged from 0.08 to 0.30 ㎛. The image registration accuracy among the software was significantly different in the x- and z-axes (P=0.009 and <0.001, respectively), but not different in the y-axis (P=0.064). Conclusion: The image registration accuracy performed by a point-based automatic image matching could be different depending on the computer software used.

Bar attachment와 Konus telescope를 이용한 부분 무치악 환자의 수복 (Clinical Appliance of Konus Telescope Denture and Bar-Retained Overdenture on Partially Edenturous Patient)

  • 최성호;심준성;이호용;이근우
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.119-126
    • /
    • 2002
  • The purpose of this study was to restorate a patient who has a few remaining teeth with #15,23,24 supported Konus telescope denture in Maxillar and #44,43,33,34 supported Dolder bar retained overdenture in Mandible. Konus telescope and bar retained overdenture was taken better results in retention, support, stability compair with regular Removable partial denture. In Removable partial denture, the change of remaining teeth and edentulous ridge is natural. But Konus telescope and bar retained overdenture is a little effected in this change, so it is possiblble in long-term use. In cosider of patient's medical history and the possibility of additional tooth loss, Konus telescope denture can be easily repaired. Compaired with Konus telescope and bar retained overdenture showed high stability and easy cleansing because of rigid support, cross - arch splinting, and simple design. In delivery, patient had a difficulty with removal of denture and plaque control, but showed better condition, good oral hygienic care. Patient satisfied with denture functionally and esthetically. This study showed Konus telescope and bar retained overdenture was effective for treatment of patient remaing a few teeth in function, esthetic and psycologic satisfaction.