• 제목/요약/키워드: ecological apartment

검색결과 269건 처리시간 0.033초

풍동실험을 통한 공동주택 지하주차장의 자연환기 성능 연구 (Experimental Study on Wind-driven Ventilation in Basement Parking Lots of Apartment)

  • 이시웅;노지웅
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.103-107
    • /
    • 2004
  • This paper aims for evaluating the wind-driven ventilation in basement parking lots of apartment. Wind tunnel tests coupled with tracer gas method were conducted, and classified by wind directions and opening types. The test results showed that, as for wind-driven ventilations, stack type openings were more successful than scuttle vent. Finally, according to Weibull distribution in Seoul, yearly averaged wind-driven ventilation rate was calculated.

공동주택에서 에너지 파일을 이용한 지열히트펌프 시스템의 성능 분석 (Performance Evaluation of Ground Source Heat Pump System Utilizing Energy Pile in Apartment)

  • 이진욱;김태연;이승복
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.41-46
    • /
    • 2012
  • In Korea, Apartment houses recently occupy over 80% of all buildings. Ground source system has to be designed to consider feature of apartment house. Most apartment houses use PHC pile to get a bearing power of the soil. Therefore, the purpose of this study is to evaluate performance of ground source heat pump system utilizing energy pile under apartment. Object of experiment is low-energy experiment apartment in Song-do and Energy Pile are applied to 80%, 100% energy reduction model for heat-source. First, performance evaluation of Energy Pile geothermal system was done during summer season. As a result, The COP(coefficient of performance) about geothermal heatpump was approximately 5-6 while cooling. In winter season, Long experiment was performed because it was very important to evaluate ground condition for long time. During heating experiment, Indoor room set temperature was $20^{\circ}C$ and kept constant by heating. Coefficient of performance for heat pump and overall system was calculated. It was 3.5-4.5 for COP and 2.5-3.7 for system COP.

공동주택 아파트 진입부 경관특성 연구 - 수도권 '살기좋은 아파트 수상'단지를 중심으로 - (Analysis on Landscape Characteristic of Entrance Spaces in the Apartment Complex - A case study of 'Award of Good Apartment to Living' in the Capital Region -)

  • 이경진;이기우
    • KIEAE Journal
    • /
    • 제8권6호
    • /
    • pp.47-55
    • /
    • 2008
  • The purpose of this study is as follows. 1) An element to organize the landscape of an apartment entrance space and setting up, a characteristic of landscape through the actual condition analysis. 2) The characteristic of the type analysis and classified the shape of the entrance as the type. 3) The degree to like the landscape analysis through the making up question. The result of this research is as follows. The entrance of the apartment complex of 71 as of 92 and set an element to organize the landscape and the characteristic of landscape through the frequency analysis and divided an entrance landscape of apartment into 4 types through the cluster analysis. An entrance landscape of apartment types of the entrance is classified as follows. 1) Type I: A model wall-fence type, 2) Type II: The side constructing a building-fence type, 3) type III: The side constructing a building-retaining wall-mixing tree type, 4) type IV: The moulding constructing a building-a retaining wall type.

BIPV의 아파트 건물 적용 가능성에 대한 연구 (A study on the application of BIPV to the Apartment Building)

  • 이응직
    • KIEAE Journal
    • /
    • 제6권1호
    • /
    • pp.25-32
    • /
    • 2006
  • Regarding to the Domestic housing politics to improve residing environment and effective use of country land, apartment buildings have been constructed since early of 1970s. Now apartment is taking over 50% out of entire housing in Korea. In the view point of PV application to the apartment, PV has amny advantages because of the wideness of out-walls and high floors building in APT. Therefore, if APT could use the electricity produced by BIPV, we can solve more easily environment and energy problems caused by housing. The research conclusion by analysing conditions and application method to introduce BIPV application to APT in near future is as below. -The out look of APT has been developed periodically and recently gable roof or canopy is popular which PV installation is more favorable. -For Balcony part with double skin facade sassy window, It has a preferable condition to install on the wall depending on the window direction. -In case of shorter distance between buildings due to high ratio of outside measurement, it is more desirable to install PV on the roof than on the wall of Apartment by considering low solar altitude. -Also depending on the direction of APT building, it is more effective and productive in electricity in the broad surface of side wall of APT. -In case of superhigh floor APT where facade system is mostly double skin facade of curtain wall system, PV module can replace the traditional curtain wall and will reduce architectural materials and obtain various out look design thereof.

아파트 단위세대 평면 형태에 따른 건물에너지효율 평가 (A Study on the Evaluation of the Building Energy Efficiency in Accordance with the Shapes of the Apartment Unit Plans)

  • 김창성;서경욱
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.55-62
    • /
    • 2013
  • Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.

공동주택의 배치유형에 따른 창호 시스템의 채광특성 (Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses)

  • 김곤;노지웅
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.37-44
    • /
    • 2008
  • Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials.

고령화 사회에 따른 국민임대아파트 1층 공유공간의 계획방향에 대한 연구 (A study on Design Planning of the National Rental Apartment's Community Space Located on Ground Level Floor for Aging Society)

  • 채민석;이주현;이현수
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.71-79
    • /
    • 2008
  • Lower birth rate and higher elder people are serious social problem in Korea. In 2003, the total birth rate is 1.19 per person, that record is lowest among OECD country. In 2005, Korea has been the aging society with 9.0% in aged population rate. Increasing of aged population results in elder estrangement and confliction with other generations. The social problem can be solved in some degree by improving housing environment and many kinds of welfare program. This study suggests a solution of the problem by applying community space located on ground level floor. The ground level floor of apartment has many physical benefits like connection to the earth, extension, safeness for the aged and child. in case of the National Rental apartment, small residential area and high rate of elder, child, the disabled make the ground level floor useful space for community. According to case study, almost the National Rental apartment hasn't enough facilities supporting various generations and don't supply comfortable environment. So, this study presents how to design the National Rental Apartment's community space located on ground level floor.

공동주택 대안적 화재 피난방식에 대한 건설전문가 평가조사 (Analysis on Field Professionals' Assessment of Alternative Fire Escape Methods in Apartment Building)

  • 이명식;이소영
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.21-28
    • /
    • 2009
  • In apartment buildings, casualties, especially fatalities have occurred in balcony areas in fires if residents fail to escape to the main entrance. Potential consequences of a particular infrequent event should be considered. In attempting to design apartment buildings for fire safety, alternative escape methods such as vertical penetration could be considered. The purpose of this study is to investigate present building regulations regarding apartment buildings and examine pros and cons of the current escape method and alternative escape methods. Focus group interview was conducted to discuss problems of fire escape methods. In addition, questionnaires were distributed to field professionals working in architecture, construction and related industries. Among 500 questionnaires distributed, 192 questionnaires were collected. Usable 162 questionnaires were analyzed using SPSS 15. Regarding alternative fire escape methods, several concerns were mentioned. Safety, privacy, security, effectiveness of escape, water proof problems were raised. Based on the opinions, vertical penetration between apartment unit appeared more safe, secure, effective than horizontal penetration. However, both methods have its own pros and cons under specific contexts. Alternative escape methods need be considered for a selective options for residents in case of fire.

수선필요도와 비용부담도 평가를 통한 공동주택 수선공사 핵심항목 도출방안 (Identification of Core Items for Repair Works of Apartment Housing by Evaluating Necessity of Repair Work and Buren of Repair Cost)

  • 송상훈;이석제;박성식
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.79-86
    • /
    • 2016
  • Purpose: Frequently, the apartment management offices have difficulties in effective repair works due to their insufficient technological capability to operate long-term repair program. There also have been many cases of failure in executing urgent repairs mainly because the repair allowance has not accumulated enough for the repair works on time. This study aimed to determine core items in apartment maintenance in order to reduce the confusion and unnecessary efforts for the management office by suggesting simple list of repair items. Method: Core items are defined using several indicators. The degrees of necessity for repair work(NRW) are calculated combining the impacts to living, safety, and aesthetics. Then the degrees of burden of repair cost(BRC) are estimated by analyzing actual long-term repair program of three apartment complexes. Lastly the degrees of accumulation demand for repair allowance(AD) are calculated with NRW and BRC. Result: The core items and essential items are suggested for three apartment types as case studies based on the indicators of NRW, BRC, and AD. Then, the required accumulated allowance per $m^2$ was calculated to effectively implement repair works.