• 제목/요약/키워드: ecological apartment

검색결과 269건 처리시간 0.023초

아파트 단지 부대복리 시설 이용과 배치유형에 관한 연구 (A Study on the Usage and plan of Indoor Community Facilities in Apartment Complex)

  • 홍동진;이효창;김나연;김정현;하미경
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.65-72
    • /
    • 2007
  • The economic growth of the modern society brought economic expansion of the national income. It is to increase the demand that faced with community or convenience facilities helping living of the residents, but the community facilities in the apartment helping living of residents do not adapt resident living conditions or demands. This study analyzes as follows the use present situation of the community facilities supplied with an apartment plan and building plans. The objective of the study is to understand a problem of an installation standard of community facililities throughout research. The study way was based on literature review, a field study and an interview with manager in the apartments. We are as follows telling the conclusion of this research. The builder must plan the facilities which the resident requests from the plan stage to the conclusion. We must consider the operation method according to the facilities. The facilities must be planed to make the contentment of the resident with the usage.

공동주택의 현장관리 인력 산출모형 연구 (A Calculation Model of Site Management Manpower for Apartment Building Construction Project)

  • 권기덕;김선국;원일우;주진규;이군재
    • KIEAE Journal
    • /
    • 제11권4호
    • /
    • pp.47-54
    • /
    • 2011
  • Construction companies find it increasingly necessary to reduce the cost as the construction market has been suffering from a depression and the industrial environment has been changing fast lately. The cost cut demands the productivity management of the field operations, which can be made feasible by assigning an appropriate number of managers on the construction site. However, previous studies are focused on the labor productivity and construction companies take into account only the revenue per worker in organizing the staff. The purpose of this study is to research the model for calculating the field management manpower in accordance with the characteristic of project and site conditions which are usually considered in the beginning of the construction project. The data about apartment building projects of domestic large constructors and factors related to them were statistically analyzed. The results of this study can be used to calculate the necessary field management manpower in accordance with the characteristic of project.

장수명 공동주택 표준모델 개발을 위한 계획요소 도출 연구 (A Study on the Elicitation of Design Elements for Development on Standard Model of Long-life Housing)

  • 박준영;정소이;정상규;박우장
    • KIEAE Journal
    • /
    • 제11권4호
    • /
    • pp.11-18
    • /
    • 2011
  • In order to solve housing shortage, an apartment has been built and supplied in large quantities in Korea. As such a result, the apartment became a typical housing type in Korea. However, the housing became vulnerable to accommodate rapidly changing life-style & life-cycle of koreans and was lost the concept of Korean traditional housing for inheriting and developing Korean traditional culture. Therefore, this paper aims at eliciting of design elements for development on standard model of long-life housing with durability & flexibility based on data derived from housing consumers's questionnaire survey and expert's opinion surveys. We expect that the standard model developed on the basis of open building applying support & infill elements will be used as a standard model for planning future long-life housing with capacity.

교육시설 유지관리 수준에 관한 전문가 의식조사 연구 (A Study on the Survey of the Experts' Consciousness as to the Level in Maintenance Management of Educational Facilities)

  • 정영한
    • KIEAE Journal
    • /
    • 제8권6호
    • /
    • pp.57-62
    • /
    • 2008
  • In case of the BTL Project for current educational faculties, the proper standards to analyze those said educational standards lack, so it is very difficult to conduct an exact analysis and those improper standards are problematic when proper management and maintenance costs are calculated. In case of such educational facilities, as students have to use them safely for a long time and the quantity of their activities and the status of their physical growth based on individual classes, as well as the features for use by facility and the regional characteristics are different, other standards for maintenance and management must be considered unlike an apartment house. Thus, in this study, to set up the standards considering the features of educational facilities, the maintenance and management level suitable for educational facilities is presented by comparing and analysing that required to maintain and manage an apartment house, targeting the experts specializing management of educational facilities.

Condensation Prevention Performance Assessment Taking Into Account Thermal Insulation Performance Degradation Due to Aging for Apartment Housing

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.11-18
    • /
    • 2015
  • Purpose: The current study analyzed trends in thermal insulation performance with aging, and condensation characteristics caused by the former. Method: Thermal insulation and condensation prevention performance of an architecture were assessed using Temperature Difference Ration Inside, or TDRi. Subjects of this quantitative analysis in thermal insulation performance change due to aging included recently constructed apartments and aged apartments older than 40 years. Time series comparison and analysis were conducted to observed changes in the thermal insulation performance and condensation characteristics. Result: Analysis showed that wall insulation performance degraded with aging regardless of fortified insulating material usage or insulating material type, which caused increased danger of condensation. In addition, when fortified insulating material was installed on the connection between the walls, insulation performance degradation was lower compared to cases in which fortified materials were not used. In all cases from 1 to 10, the rate of thermal insulation performance degradation increased after 20 years of aging.

공동주택 지하주차장의 자연채광 실태 및 채광성능 평가 (Daylighting of Underground Parking Lots in Apartment Housings by Field Survey and Performance Evaluation)

  • 정유근;김정태
    • KIEAE Journal
    • /
    • 제2권2호
    • /
    • pp.39-44
    • /
    • 2002
  • Recently, underground spaces can be usually applied to the alternative of land use for parking. However, lack of window and natural light are among the most cited drawbacks associated with dark image of underground. If underground parking lots are designed to be positive and safe environment for people, openings for daylighting will play a significant role. The natural light and unobstructed view to outdoor are main elements to create optimal underground parking lots. This paper focuses on investigating the actual day lighting conditions and evaluating the day lighting performance of openings as potential lighting resources. For the study, the field measurements and Questionnaire surveys are conducted. And then, the day lighting performance of underground parking lots based on opening geometry and orientation are evaluated by scaled model experiments. As results, the feelings of safety and orientation of underground parking lots are improved by openings for day lighting regardless of the sizes. The required illuminances (daylight factor 0.5%) for underground parking lots can be satisfied in the skylight opening ratio of 4% or more.

초고층 공동주택의 평수와 층수에 따른 바닥충격음 차음 특성 (Impact Sound Insulation Characteristics of Floors according to the number of P'yong and Layers)

  • 이상우
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.71-78
    • /
    • 2004
  • Apartment housing is a widely-spread type in Korean housing market. Nevertheless, it has caused serious problems such as traditional community corruption, unsafe structure, defects and litigation from noise. Noise, especially in concrete structure for apartment housing, is hardly controlled in proper to prevent sound transmission between upper and lower families with existing system. In foreign countries, there are floating floor system to enhance the noise control performance in multi-family housing. This study is to examine the impact sound insulation performance of floors according to the different P'yong and Layers by field measurement in highrise building.

선행연구 분석을 통한 녹색건축 인증제의 개선방향에 관한 연구 - 공동주택 부문을 중심으로 (A Study on the Improvement of G-SEED through Analysis of the Previous Studies - Based on Apartment Houses)

  • 윤요선;류수훈
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.31-42
    • /
    • 2013
  • Green Standard for Energy and Environmental Design (G-SEED) is evaluates the eco-friendliness of the building as an abjective means. Study in green building is made actively, and is being developed through constant revision. However, study results of green building have not been fully reflected in the standard. Therefore, this study analyzes the previous studies about G-SEED and checks the reflection of requirements. This study will be a reference of future revision of G-SEED. Score of items are divided into low and high score items. These items should be reflected appropriately in the standard through the score adjustment. Some requirements proposed in previous studies was reflected, while substantial requirements was not reflected. Proposed improvement requirements are classed as to establish specific standards, strengthen standards, propose a new evaluation method to existing items, and add new items.

지역난방 아파트의 난방 관리 실태에 관한 연구 (A Study on the Residential Energy Management of Apartment in the District Heating Area)

  • 최남숙
    • 가정과삶의질연구
    • /
    • 제7권1호
    • /
    • pp.79-95
    • /
    • 1989
  • Household energy consumption had influenced on the ecological system's environment. Household's exceeding energy consumption requires the development of resources and the risk. Thus this study attempted to find the household heating management, The purpose of this study was to investigate the household's heating management in the area of district heating. The major finding were; 1) The district heating was accepted positively and the benefit of this system was utilized very well in the household. 2) Variances in heating energy consumption was explained by the family size at October, residential period at October and November and the temperature of living room at October, November and December. 3) Compaired to central heating apartment, the low heating expenditure was characterize in the household of 4-5 persons, nuclear family at October, moderated heating control, using extra heating facilities at November. An in the December, that household was that husband has graduated college, temperature of the living room was some cold, and house wives was the full-time homemaker.

  • PDF

공동주택 지하주차장의 풍력환기 성능에 관한 연구 - 환기구 면적 및 주변건물의 영향 - (A Study on Ventilation Performance driven by Wind Force in Underground Parking Lots of Apartment - Influence of Opening Size and Surrounding Building -)

  • 노지웅
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.29-34
    • /
    • 2012
  • As a series of studies about natural ventilation driven by wind in basement parking lots of apartment, the influence of opening size and surrounding buildings on ventilation rate was analyzed. Natural ventilation in underground parking lots almost rely on wind than temperature difference. To investigate natural ventilation driven by wind, wind tunnel tests by using scale model and tracer gas method were conducted. $CO_2$-gas concentration was measured, natural ventilation rates were calculated. The experimental results showed that the natural ventilation rate is more reliable to wind direction and surrounding building than opening size and distance between buildings. It was verified that surrounding buildings play a principal role in increasing air flow rate by accelerating wind speed, and growing turbulence intensity. And it showed that ventilation performance is able to be increased by oblique wind to entrance ramp than head on wind in underground parking lots with surrounding buildings.