• Title/Summary/Keyword: echo time

Search Result 454, Processing Time 0.024 seconds

Analysis of the peak particle velocity and the bonding state of shotcrete induced by the tunnel blasting (발파시 터널 숏크리트의 최대입자속도와 부착상태평가 분석)

  • Hong, Eui-Joon;Chang, Seok-Bue;Song, Ki-Il;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.247-255
    • /
    • 2010
  • Bonding strength of shotcrete is a significant influential factor which plays the role of collapse prevention of tunnel crown and of debonding prevention of shotcrete induced by the blasting vibration. Thus, the evaluation of the shotcrete bonding state is one of the core components for shotcrete quality control. In this study, the peak particle velocities induced by blasting were measured on the shotcrete in a tunnel construction site and its effect on the bonding state of shotcrete is investigated. Drilling and blasting technique was used for the excavation of intersection tunnel connecting the main tunnel with the service tunnel. Blast-induced vibrations were monitored at some points of the main tunnel and the service tunnel. The shotcrete bonding state was evaluated by using impact-echo test coupled with the time-frequency domain analysis which is called short-time Fourier transformation. Analysis results of blast-induced vibrations and the time-frequency domain impact-echo signals showed that the blasting condition applied to the excavation of intersection tunnel hardly affects on the tunnel shotcrete bonding state. The general blasting practice in Korea was evaluated to have a minor negative impact on shotcrete quality.

Evaluation of UTE Signal Acquisition Efficacy in Molecular MRI (분자 MR영상에서 UTE 신호의 효용성 평가)

  • Lee, Sang-Bock;Choi, Gui-Rack
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.305-311
    • /
    • 2012
  • This study compares the TE and UTE is to evaluate. We was programming by DWT of Matlab Tool-box for evaluation. M-program used feature value extract between TE Images and UTE Images. Two images using the extracted feature values were compared. Comparison of similar features two images phase was found to have value.

Application of wavelet transform in electromagnetics (Wavelet 변환의 전자기학적 응용)

  • Hyeongdong Kim
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.9
    • /
    • pp.1244-1249
    • /
    • 1995
  • Wavelet transform technique is applied to two important electromagnetic problems:1) to analyze the frequency-domain radar echo from finite-size targets and 2) to the integral solution of two- dimensional electromagnetic scattering problems. Since the frequency- domain radar echo consists of both small-scale natural resonances and large-scale scattering center information, the multiresolution property of the wavelet transform is well suited for analyzing such ulti-scale signals. Wavelet analysis examples of backscattered data from an open- ended waveguide cavity are presented. The different scattering mechanisms are clearly resolved in the wavelet-domain representation. In the wavelet transform domain, the moment method impedance matrix becomes sparse and sparse matrix algorithms can be utilized to solve the resulting matrix equationl. Using the fast wavelet transform in conjunction with the conjugate gradient method, we present the time performance for the solution of a dihedral corner reflector. The total computational time is found to be reduced.

  • PDF

A Study on Applicability of Numerical Analyses for Stress Wave-Based NDE Techniques (응력파를 이용한 비파괴 탐상기법의 수치해석 적용성에 관한 연구)

  • 이영준;이종세
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.504-512
    • /
    • 2003
  • Simulation programs have been developed and used as an attempt to improve the accuracy of Non-Destructive Evaluation(NDE) techniques. The applicability of these programs is very limited, however, because it is difficult to describe the delicacy of the propagation of stress waves. To investigate the applicability of the finite element analysis for stress wave-based NDE techniques numerical simulation for Impact-Echo method and SASW method is performed. The numerical studies are performed to determine the essential parameters such as contact time of impact load, mesh size and time step size. These studies show that the choice of parameter is very important for improving the accuracy and confidence of the numerical procedure and, thereby, the applicability of the numerical analysis for stress wave-based NDE techniques

  • PDF

Wavelet Transform Based Deconvolution for Improvement of Time-Resolution of A-Scan Ultrasonic Signal (A-Scan 초음파 신호의 시간분해능 향상을 위한 웨이브렛 해석 기반 디컨벌루션 기법)

  • Ha, Job;Jhang, Kyung-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.84-89
    • /
    • 2001
  • Ultrasonic pulse echo method comes to be difficult to apply to the multi-layered structure with very thin layer, because the echoes from the top and the bottom of the layer are overlapped. Conventionally method, deconvolution technique has been used for the decomposition of overlapped UT signals, however it has disabilities when the waveform of the transmitted signal is distorted according to the propagation. In this paper, the wavelet transform based deconvolution (WTBD) technique is proposed as a new signal processing method that can decompose the overlapped echo signals in A-Scan signal with superior performances compared to the conventional deconvolution technique. Performances of the proposed method are shown by through computer simulations using model signal with noise and are demonstrated by through experiments for the fabricated acryl rod with a thin steel plate bonded to it.

  • PDF

Magnetic field Inhomogeneity measurement algorithm using magnetic resonance (자기 공명 영상을 이용한 불균일 자계 측정 알고리즘)

  • Kim, H.J.;Kim, C.Y.;Han, S.Y.;Yoon, J.H.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2809-2811
    • /
    • 1999
  • In this paper, we develope an algorithm to calculate field inhomogeneity in MR imaging using a dual fast spin echo pulse sequence. Because phase modulation time can be easily modified with this pulse sequence, high resolution image can be obtained and acquisition time can be reduced compared to gradient echo technique. In the case of phase wrapping in field map, phase corrected using image processing technique. We assume the field pattern to be second order polynomial and apply Pseudo-Inverse equation to calculate second order polynomial coefficients. These coefficients can be used for the shimming of the magnetic field.

  • PDF

A Performance Analysis on the Time Spread Highlight Synthesized Models for Underwater Active Target (수중 능동표적에 대한 시간분산 하이라이트 합성모델 성능분석)

  • 김부일;이형욱;박명호
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.37-44
    • /
    • 2002
  • An echo signal in the active sonar using a high frequency is mainly formed of a specular reflection from the surface of an object along with several equivalent scatter inside, which are characterized by the spatial distribution of the highlights on the object. This thesis proposed a model in which the synthesized echo signal can be expressed as a distributed simulated target. The proposed model is obtained after composing a signal based on the movement of highlights relative to the aspect angle from the discontinuous point of an external hull with a strong reflection from a spheroid underwater target. Because the proposed algorithm includes a synthesis of the signals related to the highlight spacial distribution, it can be applied to all kinds of systems used at a short range, and similar results were obtained to the actual measured results of all reflected signals in previous literature referring to the irregular factor application of an envelope.

Subband Sparse Adaptive Filter for Echo Cancellation in Digital Hearing Aid Vent (디지털 보청기 벤트 반향제거를 위한 부밴드 성긴 적응필터)

  • Bae, Hyeonl-Deok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.538-542
    • /
    • 2018
  • Echo generated in digital hearing aid vent give rise to user's discomfort. For cancelling feedback echo in vent, it is required to estimate vent impulse response exactly. The vent impulse response has time varying and sparse characteristics. The IPNLMS has been known a useful adaptive algorithm to estimate vent impulse response with these characteristics. In this paper, subband sparse adaptive filter which applying IPNLMS to subband hearing aid structure is proposed to cancel echo of vent by estimating sparse vent impulse response. In the propose method, the decomposition of input signal to subband can pre-whiten each subband signal, so adaptive filter convergence speed can be improved. And the poly phase component decomposition of adaptive filter increases sparsity of each components, and the better echo cancellation can be possible without additional computation. To derive coefficients update equation of the adaptive filter, by defining the cost function based weight NLMS is defined, and the coefficient update equation of each subband is derived. For verifying performances of the adaptive filter, convergence speed, and steady state error by white signal input, and echo cancelling results by real speech input are evaluated by comparing conventional adaptive filters.

Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature

  • Jerban, Saeed;Szeverenyi, Nikolaus;Ma, Yajun;Guo, Tan;Namiranian, Behnam;To, Sarah;Jang, Hyungseok;Chang, Eric Y.;Du, Jiang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.202-209
    • /
    • 2019
  • Purpose: To investigate the temperature-based differences of cortical bone ultrashort echo time MRI (UTE-MRI) biomarkers between body and room temperatures. Investigations of ex vivo UTE-MRI techniques were performed mostly at room temperature however, it is noted that the MRI properties of cortical bone may differ in vivo due to the higher temperature which exists as a condition in the live body. Materials and Methods: Cortical bone specimens from fourteen donors ($63{\pm}21$ years old, 6 females and 8 males) were scanned on a 3T clinical scanner at body and room temperatures to perform T1, $T2^*$, inversion recovery UTE (IR-UTE) $T2^*$ measurements, and two-pool magnetization transfer (MT) modeling. Results: Single-component $T2^*$, $IR-T2^*$, short and long component $T2^*s$ from bi-component analysis, and T1 showed significantly higher values while the noted macromolecular fraction (MMF) from MT modeling showed significantly lower values at body temperature, as compared with room temperature. However, it is noted that the short component fraction (Frac1) showed higher values at body temperature. Conclusion: This study highlights the need for careful consideration of the temperature effects on MRI measurements, before extending a conclusion from ex vivo studies on cortical bone specimens to clinical in vivo studies. It is noted that the increased relaxation times at higher temperature was most likely due to an increased molecular motion. The T1 increase for the studied human bone specimens was noted as being significantly higher than the previously reported values for bovine cortical bone. The prevailing discipline notes that the increased relaxation times of the bound water likely resulted in a lower signal loss during data acquisition, which led to the incidence of a higher Frac1 at body temperature.

Ultrasound Image Enhancement Based on Automatic Time Gain Compensation and Dynamic Range Control

  • Lee, Duh-Goon;Kim, Yong-Sun;Ra, Jong-Beom
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.294-299
    • /
    • 2007
  • For efficient and accurate diagnosis of ultrasound images, appropriate time gain compensation(TGC) and dynamic range(DR) control of ultrasound echo signals are important. TGC is used for compensating the attenuation of ultrasound echo signals along the depth, and DR controls the image contrast. In recent ultrasound systems, these two factors are automatically set by a system and/or manually adjusted by an operator to obtain the desired image quality on the screen. In this paper, we propose an algorithm to find the optimized parameter values far TGC and DR automatically. In TGC optimization, we determine the degree of attenuation compensation along the depth by dividing an image into vertical strips and reliably estimating the attenuation characteristic of ultrasound signals. For DR optimization, we define a novel cost function by properly using the characteristics of ultrasound images. We obtain experimental results by applying the proposed algorithm to a real ultrasound(US) imaging system. The results verify that the proposed algorithm automatically sets values of TGC and DR in real-time such that the subjective quality of the enhanced ultrasound images may be sufficiently high for efficient and accurate diagnosis.