• Title/Summary/Keyword: echo reduction

Search Result 65, Processing Time 0.021 seconds

The Analysis of Brain Tumor's Grades Using Magnetic Resonance Spectroscopy (대뇌 종양에서 자기공명 분광법 적용 결과의 분석 연구)

  • Yun, Sang-Jun;Lim, Jong-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.355-365
    • /
    • 2008
  • Purpose : This study isto determine the grade of brain tumor and compare the characteristics in each grade using in MRS (MR Spectroscopy). Method : STEAM (Stimulated Echo Acquisition Method) and protocol of PRESS (Point Resolved Spectroscopy) were used in the levels of tumor grade. We classified the pattern of tumor and analysis of the spectrum signals quantitatively from voxel in the brain tumor grade. In accordance with the result, we calculated the accuracy of biochemical. Result : In high-grade tumor, the NAA/Cr showed the signal reduction of 29.4% and 53.9%. However Cho/Cr increased 570% and 711%. However, in low-grade tumor, NAA/Cr downed to 42.6% and 58.1%. Cho/Cr increased to 188% and 195%. Conclusion : The study suggests that the comparative analysis of signals from MR spectroscopy could be useful to evaluate the grade of tumor and find out the characteristics of it. By extension, MR spectroscopy can be used for research with other organs in the human.

  • PDF

Material Noise Reduction in Ultrasonic Test Using Polarity Thresholding Algorithm (초음파탐상 수행시 Polarity Thresholding 알고리즘을 이용한 재료잡음 억제)

  • Koo, Kil-Mo;Ko, Dae-Sik;Kim, Tae-Hyoun;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • In this paper, Polarity Thresholding(PT) algorithm has been studied to enhance the received signal in ultrasonic inspection of the stainless-steel(SUS 304) which is the primary piping material of a nuclear power plant. The spectral decomposition components obtained by splitting the spectrum of received signals are composed of dispersive signal of the interference pattern produced by the grain boundaries and nondispersive signal by the flaw. PT algorithm enhance the SNR of received signal by using above properties. In experiment the stainless-steel has been chosen as the sample and heat-treated at 1125, 1150, 1175, and $1200^\circ{C}$, respectively. And the flat-bottom hole type defects have been made artificially in samples. The pulse-echo signals from the sample by using ultrasonic transducer of center frequency 5 MHz have been processed by PT algorithm. It has been shown that PT algorithm enhanced the SNR by average 14.2 dB.

  • PDF

An Adaptive AEC Based on the Wavelet Transform Using M-channel Subband QMF Filter Banks (M-채널 서브밴드 QMF 필터뱅크를 이용한 웨이브릿변환기반 적응 음향반향제거기)

  • 안주원;권기룡;문광석;김문수
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.4
    • /
    • pp.347-355
    • /
    • 2000
  • This paper presents an adaptive AEC(acoustic echo canceller) based on the wavelet transform using M-channel subband QMF filter banks. The proposed algorithm improves the performance of AEC with a realtime process by a low complexity of wavelet transform filter banks, a subband processing and a orthogonality of wavelet subband filter. Adaptive filter coefficients of each subband are updated using LMS algorithm with a low complexity and a easy realization for a realtime processing and a reduction of hardware cost. For a input signal, a white Gaussian noise and a real speech signal with a environment noises are used for a performance estimation of the proposed algorithm. As a result of computer simulation, the proposed AEC has a low asymptotic error, a low computation complexity and a robust performance.

  • PDF

Conversational Quality Measurement System for Mobile VoIP Speech Communication (모바일 VoIP 음성통신을 위한 대화음질 측정 시스템)

  • Cho, Jae-Man;Kim, Hyoung-Gook
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.71-77
    • /
    • 2011
  • In this paper, we propose a conversational quality measurement (CQM) system for providing the objective QoS of high quality mobile VoIP voice telecommunication. For measuring the conversational quality, the VoIP telecommunication system is implemented in two smart phones connected with VoIP. The VoIP telecommunication system consists of echo cancellation, noise reduction, speech encoding/decoding, packet generation with RTP (Real-Time Protocol), jitter buffer control and POS (Play-out Schedule) with LC (loss Concealment). The CQM system is connected to a microphone and a speaker of each smart phone. The voice signal of each speaker is recorded and used to measure CE (Conversational Efficiency), CS (Conversational Symmetry), PESQ (Perceptual Evaluation of Speech Quality) and CE-CS-PESQ correlation. We prove the CQM system by measuring CE, CS and PESQ under various SNR, delay and loss due to IP network environment.

Categorized VSSLMS Algorithm (Categorized 가변 스텝 사이즈 LMS 알고리즘)

  • Kim, Seon-Ho;Chon, Sang-Bae;Lim, Jun-Seok;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.815-821
    • /
    • 2009
  • Information processing in variable and noisy environments is usually accomplished by means of adaptive filters. Among various adaptive algorithms, Least Mean Square (LMS) has become the most popular for its robustness, good tracking capabilities and simplicity, both in terms of computational load and easiness of implementation. In practical application of the LMS algorithm, the most important key parameter is the Step Size. As is well known, if the Step Size is large, the convergence rate of the algorithm will be rapid, but the steady state mean square error (MSE) will increase. On the other hand, if the Step Size is small, the steady state MSE will be small, but the convergence rate will be slow. Many researches have been proposed to alleviate this drawback by using a variable Step Size. In this paper, a new variable Step Size LMS(VSSLMS) called Categorized VSSLMS (CVSSLMS) is proposed. CVSSLMS updates the Step Size by categorizing the current status of the gradient, hence significantly improves the convergence rate. The performance of the proposed algorithm was verified from the view point of convergence rate, Excessive Mean Square Error(EMSE), and complexity through experiments.

A Study on the Artifact Reduction Method of Magnetic Resonance Imaging in Dental Implants and Prostheses (치아 임플란트와 보철에서 발생하는 자기공명영상의 인공물 감소방안 연구)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1025-1033
    • /
    • 2019
  • Although magnetic resonance imaging without linear hardening of CT is recognized as a method of obtaining high contrast of tissue and excellent resolution image in brain disease and head and neck examination, magnetic susceptibility artifact is generated in case of metal implants in the oral cavity, which is an obstacle to image diagnosis. Therefore, an effort was made in this thesis to find a method to reduce artifacts caused by dental implants and prosthesis in MRI. Implant-induced artifacts in magnetic resonance imaging showed that the signal size increased with shorter TE in GE technique and was inconsistent with water temperature change. In SE technique as well, the signal size of water was generally higher than that of air, but the signal to noise ratio (SNR) was not different by air and temperature. In EPI technique, images with fewer artifacts were obtained quantitatively and qualitatively when there was more water than air, and the signal to noise ratio was measured the highest, especially at water temperatures of 20° and 30°. In conclusion, when examining using the EPI technique rather than the SE or the GE technique, obtaining brain diffusion using a 20° and 30° water bag reduces the magnetic susceptibility artifacts caused by implants and prosthesis, suggesting that it may provide images with high diagnostic value.

In Vivo $^1H$ MR Spectroscopic Study on Levodopa-Treated Parkison's Disease

  • Choe, Bo-Young;Baik, Hyun-Man;Son, Byung-Chul;Kim, Moon-Chan;Kim, Euy-Neyung;Suh, Tae-Suk;Lee, Hyoung-Koo;Shinn, Kyung-Sub
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.4 no.1
    • /
    • pp.19-28
    • /
    • 2000
  • Authors evaluated alterations of observable metabolite ratios between the cerebral lesion and the contralateral region related to the clinical symptomatic side in levodopa-treated Parkinson's disease (PD) and investigated correlation between age in patients with PD and metabolite ratios of the lesion. Patients with levodopa-treated PD (n = 54) and age-matched normal controls (n = 15) underwent magnetic resonance spectroscopy (MRS) examinations using a stimulated echo acquisition mode (STEAM) pulse sequence that provided 2$\times$2$\times$2 cm3 volume of interest in the selected regions of substantia nigra (SN) and putamed-globus pallidus (PG). To evaluate dependence of metabolite ratios on age, we divided into two groups (i.e., younger and older age). We quantitatively measured N-acetylaspartate (NAA), creatine (Cr), choline-containing compounds (Cho), inositols (Ins), and the sum of glutamate (Glx) and GABA levels and obtained proton metabolite ratios relative to Cr using a Marquart algorithm. Compared with the contralateral region, a significant neuronal laterality of the NAA/Cr ratio in the lesion of SN related to the clinical symptomatic side was established (P = 0.01), but was not established in the lesion of PG (P = 0.24). Also, Cho/Cr ratio tended toward significance in the lesion of SN (P = 0.07) and was statistically significant in the lesion of PG(P = 0.01). Compared with that in the younger age group, NAA/Cr ratio in the older age was decreased in the lesion of SN (P = 0.02), while NAA/Cr ratio was not statistically significant in the lesion of PG ( P = 0.21). Significant metabolic alterations of NAA/Cr and Cho/Cr ratios might be closely related with functional changes of neuropathological process in SN and PG of levodopa treated PD and could be a valuable finding for evaluation of the PD. A trend of NAA/Cr reduction, being statistically significant in older patients, could be indicative of more pronounced neuronal damage in the SN of the progressive PD.

  • PDF

Combined MRI and Relaxogram: A New Method of Fat Study (MRI와 Relaxogram을 이용한 지질 연구의 새로운 기법에 관한 연구)

  • Yongmin Chang;Yoo, Done-Sik;Kim, Tae-Hun;Kim, Yong-Joo;Kang, Duk-Sik;Robert B. Clarkson
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.23-32
    • /
    • 1999
  • Combined MRI and Relaxogram approach was introduced as a very useful tool for fat study. The phantoms simulating homogeneous mixture of fat and non-fat environments were measured with spin echo pulse sequence on a 0.15 T whole body imager. From 45 scans, the Tl values were obtained by fitting the data to continuous distribution (CONTIN) of relaxation time. This relaxogram gives broad distributions of relaxation time, which are characterized by a number of peaks with characteristic T1 values. Two distinct peaks in relaxogram were observed and identified as signals from com oil and gelatin gel. This model system can be served as simulating the distribution of fat in muscle. Also the relative ratio of two components, which is proportional to the area under the peak, is estimated and compared to nominal values. Based on the good agreement between two predictions, the values from our proposed method agreed with nominal values within $\pm$7 % error. The effects of different concentration of contrast agent and different region of interest are presented. To optimize total scan times, the minimum required data points and so further reduction in total scan times are discussed.

  • PDF

Neuronal Dysfunction in Patients with Chronic Alcoholism Evaluated by In Vivo $^1H$ Magnetic Resonance Spectroscopy (알콜중독환자의 신경기능 장애: 생체 양성자 자기공명분광 연구)

  • Bo-Young Choe;Euy-Neyng Kim;Chang-Wook Lee;In-Ho Baik;Kwang-Soo Lee;Byung-Chul Son;Heung-Jae Chun;Hyoung-Koo Lee;Tae-Suk Suh
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.94-99
    • /
    • 2000
  • Purpose : With the use of localized, water-suppressed in vivo $^1H$ magnetic resonance spectroscopy (MRS), we evaluated the proton metabolic alterations in patients with chronic alcoholism and healthy normal controls. Material and Methods : Patients with chronic alcoholism (N = 10) and normal control subjects (N = 10) underwent MRS examinations using a stimulated echo acquisition mode (STEAM) pulse sequence with $2{\times}2{\times}2{\;}\textrm{cm}^3$ volume of interest (VOI) in the left cerebellum and basal ganglia. Proton metabolite ratios relative to creative (Cr) were obtained using a Marquart algorithm. Results : The specific feature in patients with chronic alcoholism was a significant decrease of N-acetylaspartate (NAA)/Cr ratio in the left cerebellum, compared with normal controls. No clear correlation of other metabolite ratios such as choline (Cho)/Cr and inositols (Ins)/Cr was established. Conclusion : Our preliminary study suggests that the reduction of NAA/Cr ratio may indicate neuronal loss in patients with chronic alcoholism. Thus, in vivo 1H MRS may be a useful modality in the clinical evaluation of patients with chronic alcoholism based on the proton metabolite ratios.

  • PDF

Diagnosis of Chronic Kidney Disease using Sonography (초음파 영상을 이용한 만성 콩팥병의 진단)

  • Ahn, Yu-Ji;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Chronic kidney disease can be treated if it is detected early, but as the disease progresses, it becomes impossible to recover. Finally, renal replacement therapy such as transplantation or dialysis should be used. Ultrasonography is used to diagnose kidney cancer, inflammatory disease, nodular disease, and chronic kidney disease. It is used to identify information about degree of inflammation using information such as kidney size, internal echo characteristics. Currently, the degree of disease in the clinic uses the value of glomerular filtration rate. However, even in ultrasound, changes in the degree of inflammation and disease can be observed. In this study, we used ultrasound images to quantify the changes in brightness, size, cortex, and subclinical changes of the kidney with progression of the disease, and compared them with the glomerular filtration rate used in clinical practice. In 105 cases, we performed 35 cases of normal kidney, 35 cases of early kidney disease, and 35 cases of terminal kidney. The brightness of the cortex of the image was obtained and the difference in brightness between the cortex and the proximal portion was obtained by the slope. The graph of the portion which was not smooth due to the ultrasonic characteristics was used as the function regrass. The size reduction was obtained from the original data. The results were as follows: It was proportional to the glomerular filtration rate. It is considered that the algorithm can be applied to the disease if the algorithm study continues.