• Title/Summary/Keyword: eccentric

Search Result 903, Processing Time 0.025 seconds

Buckling Experiment of Eccentric Seismic Bracing Devices for Branch Lines (내진설계용 편심방식 가지배관 고정장치의 좌굴 실험)

  • Changsoo, Oh;Jihoon, Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.9-14
    • /
    • 2024
  • Restraints of Branch Lines are used as earthquake-resistant support devices for fire-fighting pipes along with sway brace devices. The central types are aligned and fixed in a straight line with center of the pipe, but the eccentric types are fixed to on side of the pipe, so a bending moment occurs. In this study, three specimens each of central type and eccentric type were installed at an angle of 45° from the vertical and a monotonic compression load of 1340N was applied. All central type samples satisfied 17.8mm of the allowable displacement, but all eccentric type samples failed to meet the target load and buckled. Therefore, when considering the performance of eccentric type restraints, both compressive load and bending moment must be considered. Even through material mechanics calculations, the yield stress of eccentric type - 3/8 inch all threaded steel bolt - exceeds 320Mpa of the allowable stress. A experiment standards need to be established for eccentric type restraints.

Seismic pounding effects on the adjacent symmetric buildings with eccentric alignment

  • Abdel Raheem, Shehata E.;Fooly, Mohamed Y.M.;Omar, Mohamed;Abdel Zaher, Ahmed K.
    • Earthquakes and Structures
    • /
    • v.16 no.6
    • /
    • pp.715-726
    • /
    • 2019
  • Several municipal seismic vulnerability investigations have been identified pounding of adjacent structures as one of the main hazards due to the constrained separation distance between adjacent buildings. Consequently, an assessment of the seismic pounding risk of buildings is superficial in future adjustment of design code provisions for buildings. The seismic lateral oscillation of adjacent buildings with eccentric alignment is partly restrained, and therefore a torsional response demand is induced in the building under earthquake excitation due to eccentric pounding. In this paper, the influence of the eccentric seismic pounding on the design demands for adjacent symmetric buildings with eccentric alignment is presented. A mathematical simulation is formulated to evaluate the eccentric pounding effects on the seismic design demands of adjacent buildings, where the seismic response analysis of adjacent buildings in series during collisions is investigated for various design parameters that include number of stories; in-plan alignment configurations, and then compared with that for no-pounding case. According to the herein outcomes, the effects of seismic pounding severity is mainly depending on characteristics of vibrations of the adjacent buildings and on the characteristics of input ground motions as well. The position of the building wherever exterior or interior alignment also, influences the seismic pounding severity as the effect of exposed direction from one or two sides. The response of acceleration and the shear force demands appear to be greater in case of adjacent buildings as seismic pounding at different levels of stories, than that in case of no-pounding buildings. The results confirm that torsional oscillations due to eccentric pounding play a significant role in the overall pounding-involved response of symmetric buildings under earthquake excitation due to horizontal eccentric alignment.

Numerical analysis and eccentric bearing capacity of steel reinforced recycled concrete filled circular steel tube columns

  • Ma, Hui;Liu, Fangda;Wu, Yanan;Cui, Hang;Zhao, Yanli
    • Advances in concrete construction
    • /
    • v.13 no.2
    • /
    • pp.163-181
    • /
    • 2022
  • To study the mechanical properties of steel reinforced recycled concrete (SRRC) filled circular steel tube columns under eccentric compression loads, this study presents a finite element model which can simulate the eccentrically compressed columns using ABAQUS software. The analytical model was established by selecting the reasonable nonlinear analysis theory and the constitutive relationship of materials in the columns. The influences of design parameters on the eccentric compressive performance of columns were also considered in detail, such as the diameter-thickness ratio of circular steel tube, replacement percentage of recycled coarse aggregate (RCA), slenderness ratio, eccentricity, recycled aggregate concrete (RAC) strength and steel strength and so on. The deformation diagram, stress nephogram and load-displacement curves of the eccentrically compressed columns were obtained and compared with the test results of specimens. The results show that although there is a certain error between the calculation results and the test results, the error is small, which shows the rationality on the numerical model of eccentrically compressed columns. The failure of the columns is mainly due to the symmetrical bending of the columns towards the middle compression zone, which is a typical compression bending failure. The eccentric bearing capacity and deformation capacity of columns increase with the increase of the strength of steel tube and profile steel respectively. Compared with profile steel, the strength of steel tube has a greater influence on the eccentric compressive performance of columns. Improving the strength of RAC is beneficial to the eccentric bearing capacity of columns. In addition, the eccentric bearing capacity and deformation capacity of columns decrease with the increase of replacement percentage of RCA. The section form of profile steel has little influence on the eccentric compression performance of columns. On this basis, the calculation formulas on the nominal eccentric bearing capacity of columns were also put forward and the results calculated by the proposed formulas are in good agreement with the test values.

An Experimental Study on the Performance of Mini-Diaphragm Pump (소형 다이아프램 펌프의 성능 특성에 관한 실험적 연구)

  • Seo, Hyeon-Seok;Kim, Tae-An;Kim, Youn-Jea
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3134-3138
    • /
    • 2007
  • The objective of this paper is to elucidate the characteristic performance of the mini-vacuum pump with various heights of eccentric shaft. The mini-diaphragm pump is composed of DC motor, eccentric shaft and diaphragm and it is operated by PCB panel. The height of eccentric shaft is changed that controls the quantities of air flow to improve the performance of vacuum pressure. This device is manufactured in order to embody the vacuum pressure with 200 mmHg. The heights of eccentric shaft which is used in present experiment are located in the range from 3 mm to 5.5 mm. The vacuum pressure distributions with each height of eccentric shaft was measured and the results were graphically depicted.

  • PDF

Biomechanical Analysis of Combination of Isotonic in Proprioceptive Neuromuscular Facilitation (고유수용성 신경근 촉진법 중 등장성수축결합의 생역학적 해석)

  • Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.260-265
    • /
    • 2002
  • There are many methods for muscle strengthening. Muscle strengthening with eccentric contraction work is the best way by researcher's report. Also, eccentric contraction need proper resistance for muscle strengthening. Combination of isotonic in PNF is a muscle strengthening method with manual resistance. It makes concentric contraction $\rightarrow$ eccentric contraction $\rightarrow$ concentric contraction with continually and without muscle relaxation. Combination isotonic technique use with PNF pattern. Therefore, it will make development and increasing of active control motion, coordination, actual range of motion, strengthen and functional training in eccentric control of movement. Concentric contraction have the 3rd lever system and eccentric contraction have the 2nd lever system with combination of isotonic. Serial concentric contraction $\rightarrow$ eccentric contraction $\rightarrow$ concentric contraction make strong SEC and PEC. It will be increase elasticity of SEC, PEC and contractile components either.

  • PDF

Comparison of Cerebral Cortical Neuron Excitability of Normal Elderly People during Concentric and Eccentric Contraction (정상 노년층의 동심성 및 편심성 수축 시 대뇌 피질신경원 흥분도 비교)

  • Kang, Jeong-Il;Choi, Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.4
    • /
    • pp.262-267
    • /
    • 2012
  • Purpose: This study was designed to analyze the differences in cerebral cortex activity of the elderly after extracting the movement related cortical potentials (MRCPs) from electroencephalogram (EEG) during a concentric and eccentric contraction of the elbow joint flexors, and entering them into the brain-mapping program to make the images. Methods: Right-dominant normal elderly people were divided into an eccentric contraction group and a concentric contraction group. Then, their MRCPs were measured using EEG and sEMG, during an eccentric and concentric contraction. Then, they were converted into images using the brain-mapping program. Results: Eccentric contraction group's $C_3$ and Cz showed statistically higher mean values of MRCP positive potential than the concentric contraction group. Conclusion: Researching a cerebral cortex activity, using MRCP, would provide basic data for clinical neuro-physiological researches on aging or neural plasticity of patients with a central nervous system injury.

The Influence of Eccentric Error in Horizontal Angle Measurement (수평각관측에 있어서 구심오차가 관측치에 미치는 영향)

  • 이계학
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1991
  • The accidential errors of horizontal angles are influenced by sighting, reading and eccentric errors etc. This paper deals with the influence of eccentric error by the formula of theory and evaluation, and actually testing measurement. The results show that the eccentric error is calculated through the sighting distance, observed angle, eccentric distance and angle. And then, three repeating method is of practical use, and also, eccentric error is able to evaluate through the sighting distance and observed angle in according to performance of each instrument.

  • PDF

Effects of Eccentric Exercise of Hip Abductors on Gait Balance (고관절 외전근의 원심성 운동이 보행시 균형에 미치는 효과)

  • Choi, Won-Ho;Kim, Myung-Jong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.9 no.2
    • /
    • pp.59-67
    • /
    • 2003
  • The purpose of this study was to identify the effects of eccentric exercise of affected hip abductor muscles on Gait balance in patient with hemiplegia. 30 patients with hemiplegia were recruited among in and out patients of Gil Hospital(age x=50.5, SD=10.1, range 37-80. post stroke days x=383.2, SD=309.3, range 57-1165). These patients were divided into eccentric and control groups by random sampling. TUG were used for this study. Paired t- test was used to identify the effects of eccentric exercise of hip. The results were stastically significantly differences in the effect of exercise between experimental and control groups by TUG(p<0.05). The results indicate that the eccentric exercise of affected hip abductor muscles is effects on gait balance in patient with hemiplegia.

  • PDF

Creep analysis of CFT columns subjected to eccentric compression loads

  • Han, Bing;Wang, Yuan-Feng;Wang, Qian;Zhang, Dian-Jie
    • Computers and Concrete
    • /
    • v.11 no.4
    • /
    • pp.291-304
    • /
    • 2013
  • By considering the creep characteristics of concrete core under eccentric compression, a creep model of concrete filled steel tubes (CFT) columns under eccentric compressive loads is proposed based on the concrete creep model B3. In this proposed model, a discrete element method is introduced to transform the eccentric loading into axial loading. The validity of the model is verified by comparing the predicting results with the published creep experiments results on CFT specimens under compressive loading, together with the predicting values based on other concrete creep models, such as ACI209, CEB90, GL2000 and elastic continuation and plastic flow theory. By using the proposed model, a parameters study is carried out to analysis the effects of practical design parameters, such as concrete mix (e.g. water to cement ratio, aggregate to cement ratio), steel ratio and eccentricity ratio, on the creep of CFT columns under eccentric compressive loading.

Distance Eccentric Connectivity Index of Graphs

  • Alqesmah, Akram;Saleh, Anwar;Rangarajan, R.;Gunes, Aysun Yurttas;Cangul, Ismail Naci
    • Kyungpook Mathematical Journal
    • /
    • v.61 no.1
    • /
    • pp.61-74
    • /
    • 2021
  • Let G = (V, E) be a connected graph. The eccentric connectivity index of G is defined by ��C (G) = ∑u∈V (G) deg(u)e(u), where deg(u) and e(u) denote the degree and eccentricity of the vertex u in G, respectively. In this paper, we introduce a new formulation of ��C that will be called the distance eccentric connectivity index of G and defined by $${\xi}^{De}(G)\;=\;{\sum\limits_{u{\in}V(G)}}\;deg^{De}(u)e(u)$$ where degDe(u) denotes the distance eccentricity degree of the vertex u in G. The aim of this paper is to introduce and study this new topological index. The values of the eccentric connectivity index is calculated for some fundamental graph classes and also for some graph operations. Some inequalities giving upper and lower bounds for this index are obtained.