• Title/Summary/Keyword: ear type

Search Result 244, Processing Time 0.02 seconds

A Proposal of Modulation Method and Vibrator Structure for the Improvement of Power Transfer Efficiency of the Implantable Middle Ear (이식형 인공중이의 전력전달효율 개선을 위한 변조방식 및 진동체 구조 제안)

  • Song, B.S.;Jung, Y.S.;Yoon, Y.H.;Won, C.H.;Kim, M.N.;Park, S.K.;Lee, S.H.;Cho, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.136-140
    • /
    • 1997
  • In this paper, we proposed a implantable middle ear system using FM transmission and receiving method which has higher detection efficiency than that of AM method. And a new shape of vibrating transducer which is more efficiently vibrate than the conventional type is designed. This tranducer consist of coil and small T-type cylindrical permanent magnet. We investigated and compared the differences between conventional methods and proposed methods by quantitive analysis. We proved them by experiment.

  • PDF

Studies on the Inhibitory effect of anaphylactic reaction by Shinisan (辛夷散에 의한 아나필락시 反應의 抑制에 관한 硏究)

  • Han, Young-mok;LIm, Gyu-sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.12 no.1
    • /
    • pp.1-17
    • /
    • 1999
  • Shinisan has been used for treatment of allergic disease in Oriental Medicine. However, its effect in experimental models remains unknown. The mast cell plays a pivotal role in initiating allergic response by secreting intracytoplasmic granular mediators such as histamine. The present report describes an inhibitory effect of Shinisan on mast cell-mediated immediate type allergic reactions. Topical application of compound 48/80 can induce an ear swelling response in normal ($WBB6F_1-+/+$) mice but not in the congenic mast cell-deficient $WBB6F_1-W/W^v$ mice. Shinisan inhibited concentration-dependently mast cell-dependent ear swelling response induced by compound 48/80. Shinisan inhibited concentration-dependently passive cutaneous anaphylaxis induced by anti-dinitrophenyl (DNP) IgE in rats by topical application. Shinisan also inhibited concentration-dependently the histamine release from the rat peritoneal mast cells by compound 48/80 or anti-DNP IgE. Moreover, Shinisan had a significant inhibitory effect on compound 48/80-induced systemic anaphylactic reaction. These results indicate that Shinisan inhibits immediate-type allergic reactions by inhibition of mast cell degranulation in vivo and in vitro.

  • PDF

Surgical Treatment of Polyotia

  • Rha, Eun Young;Kim, Dong Hwi;Byeon, Jun Hee
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.2
    • /
    • pp.84-87
    • /
    • 2015
  • Polyotia is an extremely rare type of the auricular malformation that is characterized by a large accessory ear. A 3-year-old girl presented to us with bilateral auricular abnormalities and underwent two-stage corrective operation for polyotia. In this report, we present the surgical details and postoperative outcomes of polyotia correction in the patient. Relevant literature is reviewed.

Design of a Noise Generator for Tinnitus Retraining Therapy Using Auditory Model (청각 모델을 이용한 이명 재훈련 치료용 잡음 발생기의 설계)

  • 이규동;이윤정;김필운;조진호;장용민;이상흔;김명남
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.369-376
    • /
    • 2004
  • The tinnitus retraining therapy(TRT) is an effective method for treating tinnitus patients. This therapy use the white noise to stimulate auditory cells for a wide frequency range. In this paper, the small white noise generator using the thermal noise is proposed. And frequency response controller which can compensate the frequency response changed by the human outer and middle ear system is proposed. We can know that proposed system is more proper type on a purpose of the tinnitus retraining therapy comparing with conventional white noise generator.

ITE Hearing Aid Specification Testing Devise Development using Probe Microphones (프로브 마이크로폰을 사용한 귓속형 보청기 성능 검사장치 개발)

  • 장순석;권유정
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1044-1047
    • /
    • 2003
  • An acoustic testing device composed of 2 probe microphones was developed for the electro-acoustic specification testing of the ITE (In-The-Ear) hearing aid (HA). The amplitude ratio and the phase difference between the incident pressure onto the HA microphone and the outward pressure of the HA receiver were measured by the present acoustic system. The microphones were particularly used because of small acoustic cavities where input and output pressures were present. The acoustic wall composed of clay completely blocks the propagation of the sound pressure between the small acoustic cavities. The system has an advantage of structural flexibility for the acoustic testing of different sizes and shapes of ITE-type HAs.

  • PDF

Electromagnetic Vibration Transducer Using Silicon Elastic Body For Implantable Middle Ear Hearing Aid Applications (이식형 중이 보청기에 적용 가능한 Si 탄성체로 구현된 전자기 진동 트랜스듀서)

  • Lee, Ki-Chan;Lee, Se-Kyu;Park, Se-Kwang;Cho, Jin-Ho;Lee, Sang-Heun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.10
    • /
    • pp.583-588
    • /
    • 2000
  • This paper presents the design and fabrication of micro electromagnetic vibration silicon elastic body characterized with small size, high efficiency and selective frequency bandwidth for Bio-MENS applications, such as implantable middle ear hearing aid. The presented electromagnetic vibration transducer that composed of wounded coil, permanent magnet and 4-beam cross type elastic body is fabricated by using of micromachining technology. The fabricated transducer has experimental characteristics, that is 5 nm/mA of an energy trasfer rate at the frequency range of 100∼2800 Hz. It has a size of $2{\times}2{\times}2.5\;mm^3$.

  • PDF

Vibration Modeling and Optimal Design of Differential Electromagnetic Transducer for Implantable Middle Ear Hearing Devices using the FEA (FEA를 이용한 이식형 인공중이용 차동전자 트랜스듀서의 진동 모델링과 최적 설계)

  • Kim Min-Kyu;Lim Hyung-Gyu;Han Chan-Ho;Song Byung-Seop;Park Il-Yong;Cho Jin-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.7
    • /
    • pp.379-386
    • /
    • 2005
  • Among various kinds of hearing aids which have been developed so far. the conventional air conduction hearing aids have some problems such as the acoustic distortion, an howling effect due to acoustic feedback. Another type of hearing aid. the cochlear implant system can be applied to the profound imparied person. However. it shows the disadvantage that there is no possibility of recovery of the acoustic organ such as ossicle. On the other hand. the implantable middle ear heaving device directly vibratos the ossicular chain and has better sound qualify. good cosmetics for appearance. and wide frequency responses so that it can overcome the defects or the conventional hearing aids. In this paper, a mathematical modeling and a momentum equation derivation of the DET has been performed. For the optimization of the structure dimension generating maximal vibrating force of the DET. the computer simulation using a finite element analysis (FEA) software has been performed. Also. the vibrating transducer has been designed to make the frequency characteristics or the transducer be similar to those of the normal middle ear. Through the experimental results, the measured vibration characteristics of the DET has been evaluated to verify the performance for the application to implantable middle ear hearing devices.

Induction of Apomixis by Chemical Mutagen Treatment and Ovule Development in Inbreed lines of Corn (옥수수 자식계통들에서 화학적 돌연변이 유발성질 처리에 따른 apomixis 유발과 배주발생)

  • 이호진;최근진;김태훈
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.5
    • /
    • pp.476-485
    • /
    • 1992
  • M1 plants which were produced from seed soaking in chemical mutagen, EMS or NaN$_3$, appeared wide morphorogical variations such as dwarf, albino, twisted leaf, white streaked leaf, and purpled stem. In mutants of reproductive organs, there were monoecious plants such as female-flower plant and male-flower plant, multiple spikes, and steriled plants among M1 plants. Also, barren stalk was increased significantly in M1 plants. Ear bagging at ear initiation stage prevented seed set on cob in normal plants. In spite of ear bagging, M1 plants which had cobs with seed set was 3.9-11.2% of stalks developed from seeds soaking with mutagens, but only three or four kernels could be matured on a cob. Ear bagging after mutagen injection into initiating ear produced 5.1-10% in cobs with seed set, but only 1.7-6.3 kernels could be matured. Cobs removed silk at four hours after artificial pollination increased the rate of cobs with seed set to 27%. Microscopic observation confirmed that ontogeny of kernels matured from ear bagging and mutagen treatment would be both adventitious and diplosporous apomictic reproduction. Chromosome set of M2 seedling was found to be diploid type in chromosomal counting of root tip. As M$_2$ plants showed an uniform appearence within each lines and their CV of plant height were ranged 4-6% in each lines, we concluded that they were apomictic progeny. But we could not find any marker traits combined with apomixis.

  • PDF

Lumped Mechanical Model of Electromagnetic Floating Mass Transducer Implanted on Human Middle Ear (이소골에 장착된 전자기 플로팅매스 진동체에 대한 집중 질량-스프링 모델의 제안)

  • Seong, Ki-Woong;Kim, Min-Woo;Lee, Jang-Woo;Lim, Hyung-Gyu;Jung, Eui-Sung;Kim, Dong-Wook;Lee, Myung-Won;Lee, Jung-Hyun;Kim, Myoung-Nam;Lee, Kyu-Yeop;Lee, Sang-Heun;Park, Il-Yong;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • Implantable middle ear hearing devices (IMEHDs) have been widely studied as an alternative hearing aids to solve the problems of conventional hearing aids. Vibration transducer of middle ear hearing aids is a key component because vibration characteristics of transducer is directly involved performance of hearing aids. So, the study about middle ear hearing aids concentrate on the transducers. A floating mass type transducer is most efficient. In this paper, we suggest a lumped mechanical model of electromagnetic floating mass transducer implanted on human middle ear. The proposed model enables analysis of the vibration characteristics of a floating mass transducer and prediction of the variation after implant on ossicle that offers a simple and easy to analyze. The parameters was drawn based on the components and the structures of transducer. The Lumped mechanical model was converted by the electrical-mechanical equivalent model, and simulated using PSpice. So, we investigated vibration characteristics of transducer influenced it's components. And we predict vibration characteristics of stapes footplate due to implanted transducer's vibration using combining model of transducer and human ear. To prove the feasibility of the suggested model, we fabricated a differential floating mass transducer (DFMT) as one of floating mass transducers and performed experiments using the human temporal bones.

The Effect of Various Methods of Cross-linking in Type I Collagen Scaffold on Cartilage Regeneration (I형 콜라겐지지체의 다양한 가교처리 방법이 연골막성 연골재생에 미치는 영향)

  • Son, Dae Gu;Lim, Joong Jae;Sohn, Kyounghee;Yang, Eun Kyung
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.723-731
    • /
    • 2006
  • Purpose: Collagen is the principal structural biomolecule in cartilage extracellular matrix, which makes it a logical target for cartilage engineering. In this study, porous type I collagen scaffolds were cross-linked using dehydrothermal(DHT) treatment and/or 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide(EDC), in the presence and absence of chondroitin-6-sulfate(CS) for cartilage regeneration. Methods: Cartilage defects were created in the proximal part of the ear of New Zealand rabbits. Four types of scaffolds(n=4) were inserted. The types included DHT cross-linked(Group 1), DHT and EDC cross- linked(Group 2), CS added DHT cross-linked(Group 3), and CS added DHT and EDC cross-linked(Group 4). Histomorphometric analysis and cartilage-specific gene expression of the reconstructed tissues were evaluated respectively 4, 8, and 12 weeks after implantation. Results: The largest quantity of regenerated cartilage was found in DHT cross-linked groups 1 and 3 in the 8th week and then decreased in the 12th week, while calcification increased. Calcification was observed from the 8th week and the area increased in the 12th week. Group 4 was treated with EDC cross-linking and CS, and the matrix did not degrade in the 12th week. Cartilage-specific type II collagen mRNA expression increased with time in all groups. Conclusion: CS did not increase chondrogenesis in all groups. EDC cross-linking may prevent chondrocyte infiltration from the perichondrium into the collagen scaffold.