• 제목/요약/키워드: dynamic line

검색결과 1,596건 처리시간 0.029초

Line-Interactive UPS for Low-Voltage Microgrids

  • Zhang, Ping;Cai, Huanyu;Zhao, Hengyang;Shi, Jianjiang;He, Xiangning
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1628-1639
    • /
    • 2015
  • Line-interactive uninterruptible power supply (UPS) systems are good candidates for providing energy storage within a microgrid. In this paper, a control scheme for a line-interactive UPS system applied in a low-voltage microgrid is presented. It is based on the Q-w and P-E droop control to achieve a seamless transition between grid-connected and stand-alone operation modes. Moreover, a new model for designing the controllers is built in the dq-frame based on the instantaneous power definition. The new-built model takes into account the dynamic performance of the output impedance of the inverter in the dq-frame and can be evaluated in the time domain. Compared to the traditional model based on the instantaneous power definition, the new-built model is more accurate to describe the dynamic performance of the system. Simulation and experimental results obtained with a microgrid consisting of two 40-kW line-interactive UPS systems are given to validate the control strategy of the line-active UPS system and the accuracy of the new-built model.

유기플라스틱 결정체의 PMR 연구 (제 1 보). 피발산 (PMR in Organic Plastic Crystals (I). Pivalic Acid)

  • 최종권;잔 그레함
    • 대한화학회지
    • /
    • 제19권3호
    • /
    • pp.149-155
    • /
    • 1975
  • 플라스틱 결정체인 피발산의 temperature-dependent wide-line NMR line width, second monent 및 spin-lattice relaxation times 의 결과는 이 결정체의 특이한 운동학적 성질 및 수소결합에 기인된 것으로 해석된다. 이 분자의 운동학적 성질은 $C_3-C_3'$ reorientation 및 self-diffusion 으로 구성 되었음을 확인했다. Wide-line NMR 연구결과는 또한 Pople-Karasz 융해설과 비교검토되었고, 이 이론과의 차이점은 피발산의 수소결합에 기인되었음을 알아냈다.

  • PDF

A fuzzy dynamic learning controller for chemical process control

  • Song, Jeong-Jun;Park, Sun-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1950-1955
    • /
    • 1991
  • A fuzzy dynamic learning controller is proposed and applied to control of time delayed, non-linear and unstable chemical processes. The proposed fuzzy dynamic learning controller can self-adjust its fuzzy control rules using the external dynamic information from the process during on-line control and it can create th,, new fuzzy control rules autonomously using its learning capability from past control trends. The proposed controller shows better performance than the conventional fuzzy logic controller and the fuzzy self organizing controller.

  • PDF

A practical identification method for robot system dynamic parameters

  • Kim, Sung-wun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.705-710
    • /
    • 1989
  • A practical method of identifying the inertial parameters, viscous friction and Coulomb friction of a robot is presented. The parameters in the dynamic equations of a robot are obtained from the measurements of the command voltage and the joint position of the robot. First, a dynamic model of the integrated motor and manipulator is derived. An off line parameter identification procedure is developed and applied to the University of Minnesota Direct Drive Robot. To evaluate the accuracy of the parameters the dynamic tracking of robot was tested. The trajectory errors were significantly reduced when the identified dynamic parameters were used.

  • PDF

로보트시스템 동적 변수의 실용적인 추정 방법 (A Practical Identification Method for Robot System Dynamic Parameters)

  • Kim, Sungkwun
    • 대한전기학회논문지
    • /
    • 제39권7호
    • /
    • pp.765-772
    • /
    • 1990
  • A practical method of identifying the inertial parameters, viscous friction and Coulomb friction of a robot is presented. The parameters in the dynamic equations of a robot are obtained from the measurements of the command voltage and the joint position of the robot. First, a dynamic model of the integrated system of the mainpulator and motor is derived. An off-line parameter identification procedure is developed and applied to the University of Minnesota Direct Drive Robot. To evaluate the accuracy of the parameters the dynamic tracking of the robot was tested. The trajectroy errors were significantly reduced when the identified dynamic parameters were used.

  • PDF

Critical seismic incidence angle of transmission tower based on shaking table tests

  • Tian, Li;Dong, Xu;Pan, Haiyang;Gao, Guodong;Xin, Aiqiang
    • Structural Engineering and Mechanics
    • /
    • 제76권2호
    • /
    • pp.251-267
    • /
    • 2020
  • Transmission tower-line systems have come to represent one of the most important infrastructures in today's society. Recent strong earthquakes revealed that transmission tower-line systems are vulnerable to earthquake excitations, and that ground motions may arrive at such structures from any direction during an earthquake event. Considering these premises, this paper presents experimental and numerical studies on the dynamic responses of a 1000 kV ultrahigh-voltage (UHV) transmission tower-line system under different seismic incidence angles. Specifically, a 1:25 reduced-scale experimental prototype model is designed and manufactured, and a series of shaking table tests are carried out. The influence of the seismic incidence angle on the dynamic structural response is discussed based on the experimental data. Additionally, the incidence angles corresponding to the maximum peak displacement of the top of the tower relative to the ground (referred to herein as the critical seismic incidence angles) are summarized. The experimental results demonstrate that seismic incidence angle has a significant influence on the dynamic responses of transmission tower-line systems. Subsequently, an approximation method is employed to orient the critical seismic incidence angle, and a corresponding finite element (FE) analysis is carried out. The angles obtained from the approximation method are compared with those acquired from the numerical simulation and shaking table tests, and good agreement is observed. The results demonstrate that the approximation method can properly predict the critical seismic incidence angles of transmission tower-line systems. This research enriches the available experimental data and provides a simple and convenient method to assess the seismic performance of UHV transmission systems.

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

70-nm 이하 급 초미세 CMOS 공정에서의 누설 전류 및 동적 전류 소비 억제 내장형 SRAM 설계 (Leakage-Suppressed SRAM with Dynamic Power Saving Scheme for Future Sub-70-nm CMOS Technology)

  • 최훈대;최현영;김동명;김대정;민경식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(2)
    • /
    • pp.343-346
    • /
    • 2004
  • This paper proposes a leakage-suppressed SRAM with dynamic power saying scheme for the future leakage-dominant sub-70-nm technology. By dynamically controlling the common source-line voltage ($V_{SL}$) of sleep cells, the sub-threshold leakage through these sleep cells can be reduced to be 1/10-1/100 due to the reverse body-bias effect, dram-induced barrier lowering (DIBL) and negative $V_{GS}$ effects. Moreover, the bit-ling leakage which mar introduce a fault during the read operation can be completely eliminated in this new SRAM. The dynamic $V_{SL}$ control can also reduce the bit-line swing during the write so that the dynamic power in write can be reduced. This new SRAM was fabricated in 0.35-${\mu}m$ CMOS process and more than $30\%$ of dynamic power saying is experimentally verified in the measurement. The leakage suppression scheme is expected to be able to reduce more than $90\%$ of total SRAM power in the future leakage-dominant 70-nm process.

  • PDF

개체지향기반 안정도 해석 프로그램 개발 및 적용 (Development and Application of Power System Stability Analysis Program Using OOP)

  • 박지호
    • 에너지공학
    • /
    • 제11권3호
    • /
    • pp.194-202
    • /
    • 2002
  • 본 논문은 객체지향 프로그램(OOP)을 사용하여 광양제철소 전력계통의 과도안정도를 모의한다. OOP는 절차식 프로그램보다 유연한 방법으로서 동적인 시스템의 모의에 여러 가지 장점이 있다. 시스템의 변화가 있으면 프로그램 전체을 수정하는 대신 필요한 부분만을 수정하면 되므로, 프로그램의 유지 및 보수가 매우 용이하다. 본 논문에서는 OOP를 이용하여 동적인 시스템의 해석을 위한 유연한 방법을 제시하였다. 시스템을 직접 사용자가 그려서 전력조류계산과 동적 안정도를 모의할 수 있는 사용자 인터페이스를 구현하여 17기의 동기발전기와 25기의 동기전동기로 구성되는 광양제철소 전력계통의 동적 안정도 해석에 적용하였다.

민감도 해석을 이용한 동적실속 제어 (Dynamic Stall Control Using Aerodynamic Sensitivity Analysis)

  • 안태술;김형진;김종암;노오현
    • 한국항공우주학회지
    • /
    • 제30권8호
    • /
    • pp.10-20
    • /
    • 2002
  • 본 논문에서는 최적화 방법을 이용하여 동적 실속을 제어하는 방법을 제시하고자 한다. 비정상 공력 민감도 해석코드는 2 방정식 난류 모델을 사용한 비정상 압축성 Navier-Stokes 해석코드로부터 직접 미분법을 사용하여 개발되었다. 목적함수는 해석이 수행되는 전시간에 대한 것보다는 매 순간의 값을 사용하였다. 매 순간의 목적함수에 대한 구배값은 민감도 해석코드를 사용하여 얻었고, 최적화는 매 시간마다 간단한 건형 직선 조사방법(linear line search)을 이용하였다. 제어 변수는 익형의 노즈 반경, 최대 두께와 흡입을 사용하였다. 계산결과는 동적 실속을 제어하는데, 본 논문에서 제시한 최적화 방법이 효과적이라는 것을 보여주고 있다.