• Title/Summary/Keyword: dynamic capacity

Search Result 1,509, Processing Time 0.028 seconds

Analysis of Bearing Capacity of Rock Socketed Pre-Bored Super Strength Piles Based on Dynamic Load Test Results (동재하시험을 통한 선단이 암반에 근입된 초고강도 매입 PHC 말뚝의 지지력 특성 분석)

  • Kim, Rakhyun;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.3
    • /
    • pp.89-100
    • /
    • 2019
  • The purpose of this study is to analyze the characteristics of bearing capacity of pre-bored super strength PHC (SSPHC) piles socketed in rocks based on dynamic load test results. Because the SSPHC piles have high compressive concrete strengths compared with those of regular high strength PHC piles, the allowable structural strengths of the SSPHC piles were increased. For optimal design of the super strength PHC piles, the geotechnical bearing capacity of the SSPHC piles should also increased to balance the increased allowable structural strength of the SSPHC piles. Current practices of pile installation apply the same amount of driving energy on both SSPHC and high strength PHC piles. As results of analyzing factors that influence bearing strength of SSPHC piles using dynamic load test, there was no relationship between SPT-N value at pile toe and end bearing capacity. But driving energy effects on end bearing capacity. In case of skin friction, driving energy had no effects. And reasonable method verifying design bearing strength is necessary because end bearing capacity is not considered sufficiently in restrike test results.

An experimental study for the coal particle separator in the pulverizer model with dynamic classifier (Dynamic classifier가 장착된 미분기 모델에서의 석탄 입자 분리 실험)

  • Lee, Gun-Myung;Kim, Hyuk-Je;Kim, Hyeuk-Pill;Kim, Sang-Hyeun;Ha, Jong-Kang
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.688-692
    • /
    • 2001
  • Three-dimensional experimental analyses were conducted in the pulverizer simplified isothermal model. The experimental model was constructed on a 1/3.5 scale of 500MW pulverized coal boiler. The purpose of this study is to investigate the characteristics of coal particle separator and the pressure loss in the pulverizer models with dynamic classifier. Without regards a shape of separator top, the results showed that the increase of dynamic classifier rpm was induced in finer coal particle. But the capacity of total mass per minute was reduced. Also, the increase of dynamic classifier rpm had no effect on total pressure loss, but an increase of inlet velocity was induced that the rise of total pressure loss in the pulverizer models with dynamic classifier.

  • PDF

Effect of dynamic range consumption for microholographic data storage system (마이크로 홀로그래픽 시스템에서 미디어의 소진효과)

  • Kim, Do-Hyung;Min, Cheol-Ki;Cho, Jang-Hyun;Kim, Nak-Yeong;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.31-35
    • /
    • 2011
  • In microholographic data storage system (MDSS), compact recording is required to achieve high capacity.[1] When the data is recorded, neighbor monomer is also affected by reaction at the focal point.[2,3] This unintended process caused more monomer consumption and degradation of total capacity. To avoid this extra consumption of dynamic range, it is required to define the effective dynamic range for MDSS. In this paper, we experimentally investigate the relation between dynamic range consumption and micro grating formation. Dynamic range consumption was monitored by real time read-out system. Micrograting was recorded with different consumption ratio and compared by diffraction efficiency of track direction. Finally, we define suitable dynamic range for MDSS.

Evaluation of Seismic Performance for Bridge Structure Using Capacity Spectrum Method (역량스펙트럼법을 이용한 교량의 내진성능평가)

  • 이창수;김승익;김현겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.75-80
    • /
    • 2000
  • Evaluation method of seismic performance has mainly used elastic spectrum analysis. This method has simplicity of analysis but deficiency of accuracy. And evaluation method of seismic performance using inelastic dynamic analysis reflects accurately inelasticity of material but hardly reflects site effects. This study suggested evaluation scheme of seismic performance for bridge structure using capacity spectrum method applied inelastic static analysis and standard design response spectrum of Korea Standard Specification for Highway Bridge. Two results, capacity spectrum method and inelastic dynamic analysis method, are very similar. As a result, this study appropriately supply both simplicity of analysis and accuracy of result.

  • PDF

A method for properties evaluation of activated charcoal sorbents in iodine capture under dynamic conditions

  • Magomedbekov, Eldar P.;Obruchikov, Alexander V.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.641-645
    • /
    • 2019
  • Experimental equipment for studying the sorption properties of iodine sorbents using radioactive methyliodide has been developed. The sorption capacity index ${\alpha}$ is proposed as a criterion parameter for assessing the quality of impregnated activated charcoals. It was found that this parameter does not depend on the dynamic conditions during the sorbent test. It was shown that values of the sorption capacity index allow to recommend iodine sorbents for industrial gas cleaning processes.

Analysis of Bearing Capacity and Safety Factor of Dynamic Load Test of Prebored and Precast Steel Pile (현장재하시험을 통한 강관 매입말뚝의 지지력 안전율 제안)

  • Park, Jong-Jeon;Jeong, Sang-Seom;Park, Jeong-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.5
    • /
    • pp.5-17
    • /
    • 2018
  • In this study, the static and dynamic load tests were carried out to propose the safety factor of steel prebored and precast piles in weathered rocks. The axial load tests have been conducted on test piles with nominal diameters of 0.508 and 0.457 m. The piles were subject to static loading tests (14 times) and dynamic loading tests (EOID 14times, Restrike 14times). The dynamic loading tests were first executed after the casting of test piles ((1) initial EOID test). (2)In the succeding 28 days from completion of construction, static load tests were performed and (3)final restrike tests were carried out after 15 days from the static test. As a result, the bearing capacity based on Davisson method was 15% higher than that of the restrike tests. The bearing capacity of the static load tests were larger than that of the dynamic tests. By comparing the safety factor through various loading tests, the safety factor of dynamic loading tests were suggested to be lowered to 1.75 from the conventional 2.0.

Bearing Capacity and Control Method of Driven Piles (기성말뚝의 지지력 거동해석과 시공관리방안)

  • 박영호;김경석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.249-258
    • /
    • 1999
  • Dynamic load and static load tests are performed on steel pipe piles and concrete piles at five construction sites in highway to compare the difference of load bearing mechanisms. At each site, one steel pile is instrumented with electric strain gages and dynamic tests are performed on the pile during installation. Damages of strain gages due to the installation are checked and static test is performed upon the same pile after two or seven days as well. It shows that load transfer from side friction to base resistance behaves somewhat differently according to the results of load-settlement analysis obtained from PDA and static load test. Initial elastic stage of load settlement curves of two load tests is almost similar. But after the yielding point, dynamic resistance of pile behaves more stiffer than static resistance, thus, dynamic load test result might overestimate the real pile capacity compared with static result. Analysis of gage readings shows that unit skin friction increases exponentially with depth. The skin friction is mobilized at the 1∼2m above the pile tip and contributes to the considerable side resistance. Comparison of side and base resistances between the measured value and the calculated value by Meyerhof's bearing capacity equation using SPT N value shows that the calculated base resistance is higher than the measured. Therefore, contribution of side resistance to total capacity shouldn't be ignored or underestimated. Finally, based upon the overall test results, a construction control procedure is suggested.

  • PDF

Influence of dynamic loading induced by free fall ball on high-performance concrete slabs with different steel fiber contents

  • Al kulabi, Ahmed K.;Al zahid, Ali A.
    • Structural Monitoring and Maintenance
    • /
    • v.6 no.1
    • /
    • pp.19-32
    • /
    • 2019
  • One way to provide safe buildings and to protect tenants from the terrorist attacks that have been increasing in the world is to study the behavior of buildings members after being exposed to dynamic loads. Buildings behaviour after being exposed to attacks inspired researchers all around the world to investigate the effect of impact loads on buildings members like slabs and to deeply study the properties of High Performance Concrete. HPC is well-known in its high performance and resistance to dynamic loads when it is compared with normal weight concrete. Therefore, the aim of this paper is finding out the impact of dynamic loads on RPC slabs' flexural capacity, serviceability loads, and failure type. For that purpose and to get answers for these questions, three concrete slabs with 0.5, 1, and 2% steel fiber contents were experimentally tested. The tests results showed that the content of steel fiber plays the key role in specifying the static capacity of concrete slabs after being dynamically loaded, and increasing the content of steel fiber led to improving the static loading capacity, decreased the cracks numbers and widths at the same time, and provided a safer environment for the buildings residents.

An Improved Algorithm for a Capacitated Dynamic Lot-Sizing Problem with Two-Stage Supply Chain (생산용량 제약하의 2 단계 공급체인에 대한 효율적인 롯사이징 알고리듬)

  • Hwang, Hark-Chin
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2008.10a
    • /
    • pp.290-296
    • /
    • 2008
  • This paper considers a two-stage dynamic lot-sizing problem constrained by a supplier's production capacity. We derive an improved O($T^6$) algorithm over the O($T^7$) algorithm in van Hoesel et al. (2005).

  • PDF

A Study on the Seismic Response Analysis of Reinforced Concrete Building (철근콘크리트 건물의 지진응답해석에 관한 연구)

  • 한상훈;이상호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.507-512
    • /
    • 1997
  • The objective of present paper is to provide the fundamental data of earthquake-resistance design such as estimating the resistance capacity and evaluating the design seismic load. With one bending failed building, it is checked and compared between real damaged result and analysis value by means of static and dynamic analysis using multi-degree of freedom system. In this analysis, four kinds of the earthquake waves are used. Through elasto-plastic seismic response analysis of reinforced concrete building, we could estimate dynamic behaviour of building.