1 |
Choi, K. C., Moon, Y. H., Oh, W. K. and Chun B. S. (2007). "The Estimation of Bearing Capacity of Auger-drilled Pile in Sand-Gravel by Dynamic Load Test", 2007 Autumn Conference of The Korean Society for Railway, pp.69-76. (in Korean)
|
2 |
Chatterjee, K., Choudhury, D., Rao, V. D. and Mukherjee, S. P. (2015), "Dynamic Analyses and Field Observations on Piles in Kolkata City", Geomechanics and Engineering, Vol.8, No.3, pp.415-440.
DOI
|
3 |
Cho, K. J., Jung, K. G., Song, C. Y. and Park, J. B. (2010), "Evaluation of the Tip Resistance of Prebored PHC Pile on Weathered Rock", KSCE 2010 Convention, pp.990-993. (in Korean)
|
4 |
Choi, S. B., Kim, B. I., Han, S. J. and Kim, S. S. (2003), "The Bearing Capacity Evaluation of Pre-Augering Piles", KSCE 2003 Convention, pp.3348-3353. (in Korean)
|
5 |
Davisson, M. T. (1972), "High Capacity Piles", Proc. Lecture Series on Innovations in Foundation Construction, ASCE, Illinois Section, Chicago, March 22, pp.81-112.
|
6 |
Davisson, M. T. (1975), "Pile Load Capacity", Proc. ASEC Conf. Design Construction and Performance of Deep Foundations, ASCE, University of California, Berkeley.
|
7 |
Goble, G. G. and Likins, G. (1996). "On the Application of PDA Dynamic Pile Testing", In Proceedings of the Fifth International Conference on the Application of Stress-Wave Theory to Piles, pp.263-273.
|
8 |
Hong, J. S., Lee, W. J., Kim, S. H. and Lee, M. W. (1995), "PILE SESSION : Study on a Evaluation of Pile Bearing Capacity using Dynamic Test", KGS Spring '95 National Conference, pp.43-44. (in Korean)
|
9 |
Hong, W. P., Chai, S. G. and Han, J. G. (2002), "Skin Friction Capacity of SDA(Separated Doughnut Auger) Pile", KSCE 2012 Convention, pp.2081-2084. (in Korean)
|
10 |
Hwang, U. S. (2019), "Study on Bearing Capacity of Ultra High Strengh End Extended PHC Pile by Loading Test", Journal of the Korea Academia-Industrial cooperation Society, Vol.20, No.3, pp.269-275. (in Korean)
DOI
|
11 |
Kim, D. G., Park, J. B., Yang, S. J., Kim, T. N. and Lee, D. M. (2017), "High Strength and Ultra High-Strength PHC Pile Test Case with High Design Load", KSCE 2017 Convention, pp.589-590. (in Korean)
|
12 |
Min, K. H., Park, K. H., Shin, J. H., Park, J. H. and Hwang, U. S. (2013). "Development and Application of Ultra High Strength PHC Pile", Journal of the Korean Geotechnical Society, Vol.29, No.6, pp.17-21. (in Korean)
|
13 |
MOLIT (1997), Structural Foundation Design Criteria, MOLIT (Ministry of Land, Transport and Maritime Affairs). (in Korean)
|
14 |
MOLIT (2003), Structural Foundation Design Criteria, MOLIT (Ministry of Land, Transport and Maritime Affairs). (in Korean)
|
15 |
Park, J. B. and Kwon, Y. H. (2017), "Realizing Study on the Results of Dynamic Load Test of the Bored Pile", KSCE 2017 Convention, pp.457-468. (in Korean)
|
16 |
MOLIT (2009), Structural Foundation Design Criteria, MOLIT (Ministry of Land, Transport and Maritime Affairs). (in Korean)
|
17 |
Park, J. (2017), "A Comparative Study on the Bearing Capacity of Dynamic Load Test and Static Load Test of PHC Bored Pile", Journal of the Korean Geo-Environmental Society, Vol.18, No.9, pp.19-31. (in Korean)
|
18 |
Park, J. B. (2004), "Strength and Friction Behavior of Cement paste poured in the Bored Pile", Journal of the Korean Geo-Environmental Society, Vol.5, No.3, pp.31-39. (in Korean)
|