• Title/Summary/Keyword: dye laser

Search Result 208, Processing Time 0.028 seconds

Wavelength tunability of XeCl laser pumped double-resonator dye laser for DIAL (DIAL용 XeCl 레이저펌핑 쌍공진기색소레이저의 파장가변특성)

  • 이용우;이주희
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.238-243
    • /
    • 1996
  • We have developed XeCl laser pumped double-resonator Dye laser and two-stage amplifier system, and generated simultaneously of alternatively two wavelengths suitable in DIAL system. The developed double-resonator is composed of 1st and 2nd diffraction orders on light incidence angle in grazing-incidence grating method with 1200 g/mm. We have obtained spectral linewidth below 10 pm and the total efficiency dependent on pump energy over 6%. The tuning ranges dependent on 1st and 2nd diffraction orders are 434~470 nm and 436~468 nm, respectively. The amplification gain and rine-450 dye laser by using the double-resonator laser system and measured the distribution of $NO_2$ concentration over Suwon as the result of transmission of laser output of 6 mJ in this DIAL system. Consequently, we have confirmed that the developed dye laser system is very useful as the tunable source for DIAL.

  • PDF

A Case of the Treatment of Surgical Scar with 595nm Pulsed Dye Laser (595nm Pulsed Dye Laser를 이용한 수술 흉터 치료 1예)

  • Park, Ki-Nam;Yoo, Seung-Jae;Chung, Man-Ki;Son, Young-Ik;Chun, Hyung-Ki;Kim, Won-Seok;Jeong, Han-Sin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.22 no.2
    • /
    • pp.175-178
    • /
    • 2006
  • Pulsed dye laser(PDL) is originally designed for the treatment of vascular lesions but also effective in improving the quality and appearance of surgical scars. Recently, 595nm Pulsed dye laser(V-beam laser), which has the advantage of deeper tissue penetration and lesser amount of purpura, is spotlighted as a new option for the treatment of surgical scar. The authors treated a surgical scar of a female patient with V-beam laser for 3 times between 4 and 12 weeks after surgery. Subjective satisfaction was improved with visual analogue scale (VAS) and objective improvements were found in parameters of vascularity, pliability and height with Vancouver Scar Scale(VSS). We report the effectiveness of V-beam laser in surgical scar of Asian patient and plan the prospective study with larger scale.

Surgical Experience of Pulsed Dye Laser Using Laryngeal Mask Airway Under General Anesthesia in Glottal Papillomatosis Patient who Had Previously Failed to Undergo Surgery Under General Anesthesia Due to Impossible Laryngeal Exposure (전신 마취하 후두 노출이 되지 않았던 후두 유두종 환자에 대하여 시도한 후두 마스크 전신 마취하 Pulsed Dye Laser 수술 치험 1예)

  • Chung, Hyun-Pil;Park, Jun-Hee;Kim, Won-Sik;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.1
    • /
    • pp.54-57
    • /
    • 2008
  • Non-visualization of larynx is one of the reasons for failure of vocal fold surgery. Many otorhinolaryngologists may have a trouble in choice of alternative treatment if they experience this situation. The laryngeal mask airway could be alternative approach for this situation. We report a glottal papillomatous patient who was treated by pulsed dye laser via laryngeal mask airway after failure of vocal fold surgery via endotracheal intubation. The patient was a 73-year-old man. Laryngoscopy revealed a severe diffuse papillomatous lesion on right true vocal cord, anterior commissure, and partial left true vocal cord. The patient was refered for difficult laryngeal exposure during laryngomicrosurgey under general endotracheal anesthesia.

  • PDF

A study on parameter analysis of Distrebuted Feedback Dye Laser system (분포 궤한용 색소레이저 시스템의 파라메타 해석에 관한 연구)

  • Park, Sang-Wook;Park, Duk-Il;Lee, Choo-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.651-654
    • /
    • 1989
  • A rate equation model describing the ultrashort pulse formation is presented. The temporal and energy behavior of the distributed feedback dye laser predicted by the model has been compared the earlier papers on DFDL's. The observed good agreement allows application of the theoretical model for picosecond laser.

  • PDF

Fabrication of Balanced CPM(Colliding Pulse Mode-locked) Ring Dye Laser (Balanced CPM(Colliding Pulse Mode-locked) 링 색소 레이저 제작)

  • 정영붕;김동호;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.185-190
    • /
    • 1990
  • Balanced CPM ring dye laser was fabricated. Pulses as short as 62 fs were measured using noncollinear second harmonic generation autocorrelator. The optimum conditions were studied by changing the concentration of staturable absorber, pumping power of Ar+ laser and alignments of the intracavity four-prism sequence.

  • PDF

Continuous pulse width variable quenched dye laser (펄스폭 연속가변 Quenched Dye Laser)

  • 황선우;이영주;김성훈;최종운
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.152-156
    • /
    • 1999
  • We have developed the pulse-width variable Quenched Dye Laser (QDL). QDL consisted of the dye cell of 5 mm length containing a $2.5{\times}10^{-3}$[mol/l] solution of Rhodamine 6G and the cylindrical lens focal length of 150 mm and quenching mirror. QDL system was pumped by s XeCl excimer laser with 150 mJ pulse energy in a 20 ns pulse at 1 Hz repetition rate. Pulse-width of QDL was measured by a noncollinear intensity autocorrelator. The focused thckness was measured by changing the position of the focusing cylindrical lens. Pulse-width of QDL as a function of the focused thickness (273.0${\mu}{\textrm}{m}$~845.0${\mu}{\textrm}{m}$) varied continuously from 86 ps to 201 ps.

  • PDF

A Study on the Improvement of Efficiency by Scribing Transparent Conducting Oxide of Dye-sensitized Solar Cell (염료감응형 태양전지의 투명 전극 식각을 통한 효율 향상 연구)

  • Seo, Hyun-Woong;Son, Min-Kyu;Lee, Kyoung-Jun;Kim, Jeong-Hoon;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.416-418
    • /
    • 2008
  • Dye-sensitized solar cell using transparent conducting oxide as electrode has large resistance such as surface resistance, charge transportation impedance in counter electrode and electrolyte, impedance between each interface. Among that resistances, surface resistance of transparent conducting oxide is relatively large. So the change of transparency has a large effect on internal resistance of dye-sensitized solar cell. Consequently, that change cause to increase or decrease the conversion efficiency. We tried to reduce the surface resistance by laser-scribing. The active area is seperated from total transparent conducting oxide by Nd:YAG laser-scribing. As a result, we achieved the improvement of efficiency about 7% and 11% in case of $0.25cm^2$ and $1.00cm^2$ dye-sensitized solar cells.

  • PDF

Experimentally Measured Rotational Reorientation Time of Coumarin 6 Laser Dye in Ethanol and Acetonitrile Solvents

  • Renuka, C.G.;Raikar, U.S.
    • Journal of Photoscience
    • /
    • v.12 no.3
    • /
    • pp.119-122
    • /
    • 2005
  • The photophysical properties of coumarin 6 laser dye have been studied in two solvents; ethanol and acetonitrile using steady-state fluorescence depolarization technique. The experimentally measured reorientation time of coumarin 6 is more or less the same in given solvents at particular temperature. It is found that coumarin 6 rotates slower in acetonitrile than in ethanol especially at higher values of viscosity over temperature. We also measure the ground and excited state dipole moments of coumarin 6 by solvent perturbation method. The results found that excited state dipole moment is greater than ground state dipole moment, which indicates that excited state is more polar than the ground state.

  • PDF

Office-Based 585 nm Pulsed Dye Laser(PDL) Laryngeal Surgery (외래에서 시행되는 585 nm 펄스다이레이져 후두수술)

  • Kim, Hyung-Tae
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.25-30
    • /
    • 2009
  • Introduction: 585 nm Pulsed dye laser (PDL) laryngeal surgery is based on the photodynamic characteristics of selective photothermolysis and photoangiolysis and recently considered to be the treatment for a variety of benign laryngeal disease. Objective: To review the indications and outcome of office-based 585nm PDL surgery and summarize new developments. Method: Retrospective study involving 402 patients was performed, The PDL surgery could be applied to various laryngeal diseases such as laryngeal papilloma, vocal fold dysplasia, laryngeal granuloma, vocal polyp, capillarectasia, scarred vocal fold and sulcus vocalis. Results : The physiologic properties of the vascular specificity of PDL provide many advantages and appear to be effective for laryngeal treatment. The PDL resulted in precise, selective coagulation of the microvasculature without damage to the surrounding tissue. Therefore PDL surgery is safe and effective for office-based treatment of benign laryngeal disease and for all patients regardless of their overall medical condition. Conclusion: PDL surgery provides potential benefits and advantage for treating common benign laryngeal disease.

  • PDF