• Title/Summary/Keyword: dye laser

Search Result 208, Processing Time 0.026 seconds

Application of Micro-Thin Laser sheet and Mixed Solvent for Micro-LIF Measurement in a Microchannel (마이크로 채널 내부의 Micro-LIF 측정을 위한 마이크로 레이저 평면빔과 혼합용매의 적용)

  • Yoon Sang Youl;Kim Jae Min;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.86-89
    • /
    • 2004
  • One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1$ to 3(3 or 5(5 pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

Study of Optimal Conditions Affecting the Photothermal Effect and Fluorescence Characteristics of Indocyanine Green

  • Seo, Sung Hoon;Bae, Min Gyu;Park, Hyeong Ju;Ahn, Jae Sung;Lee, Joong Wook
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.554-561
    • /
    • 2021
  • Indocyanine green (ICG) is a cyanine dye that has been used in medical diagnostics based on fluorescence imaging, and in medical therapy based on the photothermal effect. It is important to systematically understand the photothermal effect and fluorescence characteristics of ICG simultaneously. By varying a number of conditions such as laser power density, laser irradiation wavelength, concentration of ICG solution, and exposure time of laser irradiation, the intensity properties of fluorescence and the temperature change induced by the photothermal effect are measured simultaneously using a charge-coupled-device camera and a thermal-imaging camera. The optimal conditions for maximizing the photothermal effect are determined, while maintaining a relatively long lifetime and high efficiency of the fluorescence for fluorescence imaging. When the concentration of ICG is approximately 50 ㎍/ml and the laser power density exceeds 1.5 W/cm2, the fluorescence lifetime is the longest and the temperature induced by the photothermal effect rapidly increases, exceeding the critical temperature sufficient to damage human cells and tissues. The findings provide useful insight into the realization of effective photothermal therapy, while also specifying the site to be treated and enabling real-time treatment monitoring.

Switching and first-passage-time distributions in a two-mode ring dye laser (2모드 색소레이저 출력의 switching과 First-Passage-Time(FPT) 분포)

  • 박구동;신종태;김태수
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.245-251
    • /
    • 1994
  • The charateristics of switching between two modes in a ring dye laser has been analyzed by the Monte-Carlo computer simulation. The effect of including pump fluctuations in the first-passage-time (FPT) distributions was compared with the distribution with the quantum fluctuation. The results show the same tendency in both cases, such as steep increases from 0 to peak an exponential decrease in long time range. However the introduction of pumping fluctuation is turned out to shorten the mean FPT. The variation of the mean FPT is examined for the various fluctuationrelated parameters. The mean FPT is lengthened when pump parameter a is increased while it is shorted when Q. $\GAMMA$ are decreased. eased.

  • PDF

Convolutive Cyclic Voltammetry Investigation of Dicarboximide Laser Dye at a Platinum Electrode in 1,2-Dichloroethane (1,2-Dichloroethane 내 백금 전극에서의 dicarboximide 레이저 염료에 대한 convolutive 순환 전압-전류법 연구)

  • Al-Bishri, Hassan M.;El-Mossalamy, E.H.;El-Hallag, Ibrahim;El-Daly, Samy
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.169-176
    • /
    • 2011
  • The electrochemical investigation of N,N-bis (2,5-di-tert-butylphenyl)-3,4,9,10 perylenebis (dicarboximide) laser dye have been carried out using cyclic voltammetry and convolution - deconvolution voltammetry combined with digital simulation technique at a platinum electrode in 0.1 mol/L tetrabutyl ammonium perchlorate (TBAP) in solvent 1,2 dichloroethane ($CH_2Cl-CH_2Cl$). The investigated dye was reduced via consumption of two sequential electrons to form radical anion and dianion (EE mechanism). In switching the potential to positive scan, the compound was oxidized by loss of two electrons, which were followed by a fast aggregation process ($EC_1EC_2$ mechanism). The electrode reaction pathway and the chemical and electrochemical parameters of the investigated compound were determined using cyclic voltammetry and convolutive voltammetry. The extracted electrochemical parameters were verified and confirmed via digital simulation method.

Micro-LIF measurement of microchannel flow

  • Kim Kyung Chun;Yoon Sang Youl
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.65-74
    • /
    • 2004
  • Measurement of concentration distributions of suspended particles in a micro-channel is out of the most crucial necessities in the area of Lab-on-a-chip to be used for various bio-chemical applications. One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1\;to\;3\times3\;or\;5\times5$ pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

SOLVING BIOANALYTICAL PROBLEMS BY THE METHOD OF MATRIX-ASSISTED LASER DESORPTION IONIZATION MASS SPECTROMETRY (MALDI-MS)

  • Zhao, Shankai;Zhong, Feng;Zhu, Zhihua
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.865-868
    • /
    • 1995
  • The method of matrix-assisted laser desorption ionization mass spectrometry has been used to solve some bioanalytical problems, which is difficult to analyse by general methods. For the selection of proper laser wavelength and matrices, eight matriees was used with laser wavelength of 226 and 355nm. The result shows that with wavelength of 355nm better results could be obtained with most of the matrices. The molecular weight of eytochrome C, which was seperated by gel electrophoresis and electro-blotted onto NC membrane is determined by MALDI. The accuracy is better than 0.1%, which is much higher than that of SDS-PAGE. Protein mixture extracted from crude peanut oil is directly determined by MALDI. The molecuiar weight of its three components are determined, and the result also demonstrated that these proteins are in free manner. As proteins arc in 2S bond, with the traditional method, SDS-PAGE, it is not able to decide whether protein exists in combination mode or in free manner. In the technique of two phase aquesous solution, which is used for separating biomaterials, water soluble polymers stained with dyes are used in this technique. By the use of MALDI the number or the dye molecules react with the polymer PEG molecule are determined, and that is difficult to determined by other methods.

  • PDF

Sensitization of Periodontitis Disease Causing Bacteria by Low Power He-Ne Laser Radiation

  • Satsangi, Akash Tripathi;Mathur, Manish;Saxena, Parul;Prasad, Guru;Shrivastava, Jitendra Nath;Shrivastava, Jenendra Nath;Roy, Sukhdev
    • Journal of Photoscience
    • /
    • v.11 no.32
    • /
    • pp.55-59
    • /
    • 2004
  • The present investigation is an attempt to create an optimized protocol for a bactericidal modality of different powers of He-Ne laser radiation to eliminate periodontitis disease causing bacteria from dental plaques. Periodontitis is most prevalent infectious disease of men and caused by a limited number of Gram negative oral bacteria. Porphyromonas gingivalis and Streptococcus sanguis are the important bacteria responsible for periodontitis diseases. Effect on periodontitis disease causing bacteria were produced by the exposure of different powers of He-Ne laser light i.e. 9 mW, 17 mW and 26 mW of red colour of wavelength 632.8 nm in two different periods of time i.e. 10 min. and 20 min. in the presence of dye Methylene blue (MB) used as a photosensitizer. The results have been shown in terms of percentage inhibition of colony forming units (cfu.) of bacteria. This study has shown that maximum inhibition of cfu. were observed in Laser+MB-20 min. exposure time. This inhibition was followed by Laser+MB-10 min., but minimum inhibition was seen in Laser only at 10 min. exposure. In case of effect of methylene alone on the cfu. of bacteria, it was seen that MB have not shown more inhibition of cfu. and it had shown that the no. of cfu. are very similar to that of control. The above observation of the present study was seen in case of every 3 different type of used powers of laser for both the bacteria. Maximum percentage inhibition of cfu. were seen in case of 26mW powers of He-Ne laser, which was 67. 28% to 61.42% for Porphyromonas gingivalis and Streptococcus sanguis respectively. So, increasing the power of laser (safe range for dentistry is 3-30 mW) under conditions shows an increased percentage inhibition of cfu. Thus the present investigation may be a useful adjunct with mechanical debridement in the prevention of recolonization of subgingival lesions by pathogenic microorganisms which are harmful and drug resistant.

  • PDF