• Title/Summary/Keyword: duty cycle control

Search Result 225, Processing Time 0.032 seconds

Modified Digital Pulse Width Modulator for Power Converters with a Reduced Modulation Delay

  • Qahouq, Jaber Abu;Arikatla, Varaprasad;Arunachalam, Thanukamalam
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.98-103
    • /
    • 2012
  • This paper presents a digital pulse width modulator (DPWM) with a reduced digital modulation delay (a transport delay of the modulator) during the transient response of power converters. During the transient response operation of a power converter, as a result of dynamic variations such as load step-up or step-down, the closed loop controller will continuously adjust the duty cycle in order to regulate the output voltage. The larger the modulation delays, the larger the undesired output voltage deviation from the reference point. The three conventional DPWM techniques exhibit significant leading-edge and/or trailing-edge modulation delays. The DPWM technique proposed in this paper, which results in modulation delay reductions, is discussed, experimentally tested and compared with conventional modulation techniques.

An automatic mask alignment system using moire sensors

  • Furuhashi, Hideo;Uchida, Yoshiyuki;Ohashi, Asao;Watanabe, Shigeo;Yamada, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.545-549
    • /
    • 1993
  • an alignment system in the X-and Y-directions an X-Y-.theta. stage driven by piezoelectric actuators is presented. A pair of quadruple gratings and a quadruple photo-detector are used. The difference between the two 0-th order moire signals in reflection with a relative spatial phase of 180.deg. is used in each direction to control the alignment of the X-Y-.theta. stage. The stage is aligned at the position where the difference is zero. The quadruple gratings are 10 mm * 10 mm, and of a binary square-type with a 1/2 duty cycle. Their pitches are 16 .mu.m. Alignment accuracy of .+-.20nm was obtained in this system.

  • PDF

CONTROL STRATEGY OF ELECTRIC COOLANT PUMPS FOR FUEL ECONOMY IMPROVEMENT

  • CHO H.;JUNG D.;ASSANIS D. N.
    • International Journal of Automotive Technology
    • /
    • v.6 no.3
    • /
    • pp.269-275
    • /
    • 2005
  • The engine cooling system for a medium duty V6, 4.5 L diesel engine was modeled with a commercial code, GT-Cool in order to investigate the effect of controllable electric pump on the cooling performance and the fuel economy. The simulation results of the cooling system model with mechanical coolant pump were validated with experimental data. Two different types of electric pumps were implemented into the cooling system model and PID control for electric pump operation was incorporated into the simulation study. Based on the simulation result with electric pump, conventional thermostat hysteresis was modified to reduce pump operation for additional improvement of fuel economy, and then the benefit of electric pumps with modified thermostat hysteresis on fuel economy was demonstrated with the simulation. The predicted result indicates that the cooling system with electric pump and modified thermostat hysteresis can reduce pump power consumption by more than $99\%$ during the FTP 74 driving cycle.

Comparison of 3.3kW SRC-OBC Switching Methods for Improving Efficiency at Light Load (3.3kW SRC-OBC의 경부하 효율 향상을 위한 스위칭 기법 비교 분석)

  • Kim, Min-Jung;Ryu, Seung-Hee;Kim, Dong-Hee;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.173-174
    • /
    • 2012
  • 본 논문에서는 전기자동차용 부하 직렬 공진형 컨버터(Series-loaded Resonant Converter, SRC)타입의 탑재형 충전기 (On-Board Charger, OBC)의 추가 회로 없이 경부하 효율을 향상시키기 위한 스위칭 방법들을 비교 분석한다. 시스템에 적용할 스위칭 제어 방법은 Asymmetrical Duty Cycle Control (ADC)과 Asymmetrical Voltage-Cancellation Control (AVC) 방법이다. 각 제어 방법을 기존의 3.3kW SRC-OBC의 적용하여 경부하 영역에서의 효율을 확인하고 각 제어 방법의 타당성을 검증한다.

  • PDF

A Study on Novel Step-Up AC-DC Chopper of High Efficiency by using Lossless Snubber Capacitor (새로운 무손실 스너버 커패시터를 이용한 고효율 스텝 업 AC-DC 초퍼에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Sang-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1103-1104
    • /
    • 2008
  • In this paper, authors propose a novel step-up AC-DC chopper operated with power factor correction (PFC) and with high efficiency. The proposed chopper behaves with discontinuous current control (DCC) of input current. The input current waveform in the proposed chopper is got to be a discontinuous sinusoid form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC chopper, the switching devices are turned-on with the zero current switching, but turn-off of the switching devices is switched at current maximum value. To achieve a soft switching of the switching turn-off, the proposed chopper is used a new partial resonant circuit. The result is that the switching loss is very low and the efficiency of chopper is high.

  • PDF

Suggestion to Improve Power Efficiency by Changing Sleep-Wakeup Period in Wireless Network Environment for Internet of things

  • Woo, Eun-Ju;Moon, Yu-Sung;Choi, Jae-Hyun;Kim, Jae-Hoon;Kim, Jung-Won
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.862-865
    • /
    • 2018
  • The proposed scheme minimizes the Idle time under the residual energy of the sensor node to adjust the Sleep-Wakeup period and minimize unnecessary energy consumption. It is The proposed scheme minimizes the Idle time under the residual energy of the sensor node to adjust the Sleep-Wakeup period and minimize unnecessary energy consumption. It is an important process to control the Application Packet Framework including the PHY and the MAC layer at each node's Idle time with the Idle time mechanism state before the proposed function is executed. The Current Control Level of the Report Attribute is fixed at one sending / receiving node where power consumption can occur, by changing Sleep-Wakeup time, the low power consumption efficiency was improved while satisfying the transmission requirement of the given delay time constraint.

Transient Analysis of a Simple Cycle Gas Turbine Engine

  • Kim, SooYong;Soudarev, B.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.22-29
    • /
    • 2000
  • A method to simulate the gas turbine transient behavior is developed. The basic principles of the method and main input data required are described. Calculation results are presented in terms of whole operating regime of the engine. The influence of initial parameters such as starting engine power, moment of inertia of the rotor, fuel schedule on performance characteristics of gas turbine during transient operation is shown. In addition, the effect of bleeding air on transient behavior is also considered. For validation of the developed computer code, a comparative analysis with experimental data obtained from a heavy duty gas turbine is made. Calculation results agree well with the experimental data for the range of operating regime studied and proved applicability of the developed technique to initial design stage of control system.

  • PDF

Design of Stable Controller to Sudden A/C Disturbance (급격한 에어콘 외란에 안정한 제어기 설계)

  • 이영춘;권대규;이성철
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.106-112
    • /
    • 2000
  • The purpose of this paper is to study on the control of the engine idle speed under sudden A/C load which is one of the most severe disturbances on engines. Three types of the closed-loop controller are developed for the stable engine idle speed control. The input of the controller is an error of rpm. The output of the controller is an ISCV duty cycle. The anticipation delay is considered to deal with the delay time of the air mass in engine. The PID, Fuzzy and PID-type Fuzzy controllers with the anticipation delay have improved the engine idle speed condition more than current ECU map table under the A/C load.

  • PDF

An Energy Efficient MAC Protocol Providing Guaranteed Service for Wireless Sensor Network

  • Kim, Dong-Won;Park, Tae-Geon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.1
    • /
    • pp.123-140
    • /
    • 2011
  • In this paper, we propose an Energy Efficient Media Access Control (EE-MAC) protocol for wireless sensor networks. The proposed scheme is designed to save power consumption and guarantee quality-of-service for real-time traffic. EE-MAC uses the superframe structure which is bounded by the transmission of a beacon frame and can have an active and an inactive portion. The active period is divided into the contention free period (CFP) for real-time traffic transmission and the contention access period (CAP) for non-real-time traffic transmission. We propose the exclusively allocated backoff scheme which assigns a unique backoff time value to each real-time node based on bandwidth allocation and admission control. This scheme can avoid collision between real-time nodes by controlling distributed fashion and take effect a statistical time division multiple access. We also propose the algorithm to change the duty cycle adaptively according to channel utilization of media depending on network traffic load. This algorithm can prolong network lifetime by reducing the amount of energy wasted on idle listening.

Regulated Incremental Conductance (r-INC) MPPT Algorithm for Photovoltaic Systems

  • Wellawatta, Thusitha Randima;Choi, Sung-Jin
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1544-1553
    • /
    • 2019
  • The efficiency of photovoltaic generation systems depends on the maximum power point tracking (MPPT) technique. Among the various schemes presented in the literature, the incremental conductance (INC) method is one of the most frequently used due to its superb tracking ability under changes in insolation and temperature. Generally, conventional INC algorithms implement a simple duty-cycle updating rule that is mainly found on the polarity of the peak-power evaluation function. However, this fails to maximize the performance in both steady-state and transient conditions. In order to overcome this limitation, a novel regulated INC (r-INC) method is proposed in this paper. Like the compensators in automatic control systems, this method applies a digital compensator to evaluate the INC function and improve the capability of power tracking. Precise modeling of a new MPPT system is also presented in the optimized design process. A 120W boost peak power tracker is utilized to obtain comparative test results and to confirm the superiority of the proposed method over existing techniques.