• Title/Summary/Keyword: durability monitoring

Search Result 136, Processing Time 0.024 seconds

Enhancement of durability of tall buildings by using deep-learning-based predictions of wind-induced pressure

  • K.R. Sri Preethaa;N. Yuvaraj;Gitanjali Wadhwa;Sujeen Song;Se-Woon Choi;Bubryur Kim
    • Wind and Structures
    • /
    • v.36 no.4
    • /
    • pp.237-247
    • /
    • 2023
  • The emergence of high-rise buildings has necessitated frequent structural health monitoring and maintenance for safety reasons. Wind causes damage and structural changes on tall structures; thus, safe structures should be designed. The pressure developed on tall buildings has been utilized in previous research studies to assess the impacts of wind on structures. The wind tunnel test is a primary research method commonly used to quantify the aerodynamic characteristics of high-rise buildings. Wind pressure is measured by placing pressure sensor taps at different locations on tall buildings, and the collected data are used for analysis. However, sensors may malfunction and produce erroneous data; these data losses make it difficult to analyze aerodynamic properties. Therefore, it is essential to generate missing data relative to the original data obtained from neighboring pressure sensor taps at various intervals. This study proposes a deep learning-based, deep convolutional generative adversarial network (DCGAN) to restore missing data associated with faulty pressure sensors installed on high-rise buildings. The performance of the proposed DCGAN is validated by using a standard imputation model known as the generative adversarial imputation network (GAIN). The average mean-square error (AMSE) and average R-squared (ARSE) are used as performance metrics. The calculated ARSE values by DCGAN on the building model's front, backside, left, and right sides are 0.970, 0.972, 0.984 and 0.978, respectively. The AMSE produced by DCGAN on four sides of the building model is 0.008, 0.010, 0.015 and 0.014. The average standard deviation of the actual measures of the pressure sensors on four sides of the model were 0.1738, 0.1758, 0.2234 and 0.2278. The average standard deviation of the pressure values generated by the proposed DCGAN imputation model was closer to that of the measured actual with values of 0.1736,0.1746,0.2191, and 0.2239 on four sides, respectively. In comparison, the standard deviation of the values predicted by GAIN are 0.1726,0.1735,0.2161, and 0.2209, which is far from actual values. The results demonstrate that DCGAN model fits better for data imputation than the GAIN model with improved accuracy and fewer error rates. Additionally, the DCGAN is utilized to estimate the wind pressure in regions of buildings where no pressure sensor taps are available; the model yielded greater prediction accuracy than GAIN.

Enhancement of Penetration by Using Mechenical Micro Needle in Textile Strain Sensor (텍스타일 스트레인 센서에 마이크로 니들을 이용한 전도성입자 침투력 향상)

  • Hayeong Yun;Wonjin Kim;Jooyong Kim
    • Science of Emotion and Sensibility
    • /
    • v.25 no.4
    • /
    • pp.45-52
    • /
    • 2022
  • Recently, interest in and demand for sensors that recognize physical activity and their products are increasing. In particular, the development of wearable materials that are flexible, stretchable, and able to detect the user's biological signals is drawing attention. In this study, an experiment was conducted to improve the dip-coating efficiency of a single-walled carbon nanotube dispersion solution after fine holes were made in a hydrophobic material with a micro needle. In this study, dip-coating was performed with a material that was not penetrated, and comparative analysis was performed. The electrical conductivity of the sensor was measured when the sensor was stretched using a strain universal testing machine (Dacell Co. Ltd., Seoul, Korea) and a multimeter (Keysight Technologies, Santa Rosa, CA, USA) was used to measure resistance. It was found that the electrical conductivity of a sensor that was subjected to needling was at least 16 times better than that of a sensor that was not. In addition, the gauge factor was excellent, relative to the initial resistance of the sensor, so good performance as a sensor could be confirmed. Here, the dip-coating efficiency of hydrophobic materials, which have superior physical properties to hydrophilic materials but are not suitable due to their high surface tension, can be adopted to more effectively detect body movements and manufacture sensors with excellent durability and usability.

Development of disc cutter wear sensor prototype and its verification for ensuring construction safety of utility cable tunnels (전력구 터널 건설안전 확보를 위한 디스크커터 마모측정시스템 시작품 개발 및 성능검증)

  • Jung Joo Kim;Hee Hwan Ryu;Seung Woo Song;Seung Chul Do;Ji Yun Lee;Ho Young Jeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.2
    • /
    • pp.91-111
    • /
    • 2024
  • Most of utility cable tunnels are constructed utilizing shield TBM as part of the underground transmission line project. The TBM chamber is the only space inside the tunnel that encounters rock and soil, and is the place with the highest frequency of accident exposure, such as collapse and collision accidents. Since there is currently no way to measure the disc cutter wear from outside the chamber, frequent inspection by workers is essential. Accordingly, in this study, in order to prevent safety accidents inside the TBM chamber and expect the effect of shortening the construction period by reducing the number of chamber openings, the concept of disk cutter wear measurement technology was established and a prototype was produced. By considering prior technology and determining that magnetic sensors are most suitable for the excavation environment, wear measurement sensor package were developed integrating magnetic sensors, wireless communication modules, power supply, external casing, and monitoring systems. To verify the performance of the prototype in an actual excavation environment, a full-scale tunnelling test was performed using a 3.6 m EPB shield TBM. Based on the full-scale tests, five prototypes were operated normally among eight prototypes. It was analyzed that sensor measurement, wireless communication, and durability performance were secured within a maximum thrust of 3,000 kN and a rotation speed of 1.5 RPM.

Packaging Technology for the Optical Fiber Bragg Grating Multiplexed Sensors (광섬유 브래그 격자 다중화 센서 패키징 기술에 관한 연구)

  • Lee, Sang Mae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.23-29
    • /
    • 2017
  • The packaged optical fiber Bragg grating sensors which were networked by multiplexing the Bragg grating sensors with WDM technology were investigated in application for the structural health monitoring of the marine trestle structure transporting the ship. The optical fiber Bragg grating sensor was packaged in a cylindrical shape made of aluminum tubes. Furthermore, after the packaged optical fiber sensor was inserted in polymeric tube, the epoxy was filled inside the tube so that the sensor has resistance and durability against sea water. The packaged optical fiber sensor component was investigated under 0.2 MPa of hydraulic pressure and was found to be robust. The number and location of Bragg gratings attached at the trestle were determined where the trestle was subject to high displacement obtained by the finite element simulation. Strain of the part in the trestle being subjected to the maximum load was analyzed to be ${\sim}1000{\mu}{\varepsilon}$ and thus shift in Bragg wavelength of the sensor caused by the maximum load of the trestle was found to be ~1,200 pm. According to results of the finite element analysis, the Bragg wavelength spacings of the sensors were determined to have 3~5 nm without overlapping of grating wavelengths between sensors when the trestle was under loads and thus 50 of the grating sensors with each module consisting of 5 sensors could be networked within 150 nm optical window at 1550 nm wavelength of the Bragg wavelength interrogator. Shifts in Bragg wavelength of the 5 packaged optical fiber sensors attached at the mock trestle unit were well interrogated by the grating interrogator which used the optical fiber loop mirror, and the maximum strain rate was measured to be about $235.650{\mu}{\varepsilon}$. The modelling result of the sensor packaging and networking was in good agreements with experimental result each other.

A Study on the Arrangement and Design of Cultural Property Signs - Focused on the Seoul Tangible Cultural Properties Located in Jongno-gu Area - (문화재 안내판의 배치와 디자인에 대한 고찰 - 종로구 소재 서울 유형문화재를 중심으로 -)

  • So, Hyun-Su;Kim, Hai-Gyoung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.66-75
    • /
    • 2012
  • The Seoul Metropolitan Government selected the sign designs of cultural heritages through a public prize contest from a public design perspective and applied the selected design format to the signs of the cultural assets that were designated by the central and Seoul governments and located in Seoul Metropolitan area in 2008. For the purpose of monitoring the result, this study analyzed the installation state of the signs of Seoul tangible cultural properties located in Jongno-gu. The scope of the analysis of this study was expanded to cover the surrounding areas of cultural heritages in order to review the arrangement and design of such signs. The result of this study can be summarized as follows; firstly, not only the flow of travelers' movement but also the direction of sight, their locations in relation to the surrounding facilities or other installations and the integration with similar signs or notices were necessary to be considered in the arrangement of the signs; secondly, the current sings had low quality in terms of durability and readability and seemed utterly distance from the cultural assets indicated by the signs because they were finished with tempered glass; thirdly, the size, shape and materials of the signs were not harmonized with their surrounding areas as only one design was used in the entire cultural property sites without considering such natural or artificial backgrounds of individual signs as rocks, plants, walls or buildings. When selecting the design format of the signs of individual cultural properties that are located dispersively as Seoul tangible cultural properties, it is recommended to determine a group of most representative designs based on natural, man-made and cultural landscape rather than one unified design format and to use a unique well-matched sign for each cultural property. For this reason, this study selected alternative exemplary design models and proposed the type of signs appropriate for each cultural site.

Rewetting Strategies for the Drained Tropical Peatlands in Indonesia (인도네시아의 배수된 열대 이탄지에 대한 재습지화 전략)

  • Roh, Yujin;Kim, Seongjun;Han, Seung Hyun;Lee, Jongyeol;Son, Yowhan
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.1
    • /
    • pp.33-42
    • /
    • 2018
  • The tropical peatlands have been deforested and converted to agricultural and plantation areas in Indonesia. To manage water levels and increase the overall productivity of crops, canals have been constructed in tropical peatlands. The canals destructed the structure of the tropical peatlands, and increased the subsidence and fire hazard risks in the region. The Indonesian government enacted regulations and a moratorium on tropical peatlands, in order to reduce degradation. A practical method under the regulations of rewetting tropical peatlands was to permit a canal blocking. In this study, four canal blocking projects were investigated regarding their planning, construction priority, design, building material, construction, monitoring, time and costs associated with the canal blockings. In the protected areas, regulations restricted the development of the tropical peatlands areas that were noted as deeper than 3 m, and the administration stopped issuing new concessions for future work projects for this noted criteria of land use. A noted purpose of canal blockings in these areas was to effectuate the restoration of the lands in the region. The main considerations of the restoration efforts were to maintain a durability of the blockings, and to encourage the participation of the area stakeholders. In the case of a concession area, regulations were set into place to restrict clear-cutting and shifting cultivation, and to maintain groundwater level in the tropical peatland. The most significant priorities identified in the canal blocking project were the efficiency and cost-effectiveness of the project. Nevertheless, the drainage of tropical peatlands has been continued. On the basis of a literature review on regulations and rewetting methods in tropical peatlands of Indonesia, we discussed the improvements of the regulations, and adequate canal blockings to serve the function to rewet the tropical peatlands in Indonesia. Our results would help establishing an adequate direction and recommended guideline on viable rewetting methods for the restoration of drained tropical peatlands in Southeast Asia.