• 제목/요약/키워드: durability factor

검색결과 444건 처리시간 0.027초

케이슨 구조물 고내구성 콘크리트 내구수명 평가 (Service Life Evaluation of High Durability Concrete in Caisson Structure)

  • 유조형;김우재;홍석범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.42-43
    • /
    • 2014
  • In order to ensure the construction of sustainable reinforced concrete structures, durability evaluation of Caisson structures before construction should be carried out. In this paper, a service life evaluation technique using a safety factor determined by a reliability theory for Caisson structures subjected to chloride attack is proposed.

  • PDF

자동차 클러치용 다이아프램 스프링 강(50CrV4)의 열처리 조건에 따른 내구특성에 관한 연구 (A Study on Durability Characteristics of Automobile Clutch Diaphragm Spring Steel According to Heat-Treatment Condition)

  • 남욱희;이춘열;채영석;권재도;배용탁;우승완
    • 한국정밀공학회지
    • /
    • 제17권2호
    • /
    • pp.137-143
    • /
    • 2000
  • An automobile clutch diaphragm spring is operating in a closed clutch housing under high temperature and subject to high stress concentration in driving condition, which frequently causes cracks and fracture. The material of spring is required to possess sufficient fatigue strength and tenacity, which depend largely on the condition of tempering heat treatment. In this paper, specimens are made under a number of different tempering temperatures md tested to find the optimal tempering heat treatment condition. The experiments include the verification of microscopic structure, hardness, tensile strength, fatigue crack growth rate, stress intensity factor range and residual stress. Also, decarbonization, which occurs in actual heat treatment process, is measured and allowable decarbonization depth is studied by durability test.

  • PDF

지붕용 톱코팅재의 내구성 향상에 관한 성능 및 평가방법에 관한 기초적 연구 (A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure)

  • 박진상;강효진;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.517-520
    • /
    • 2006
  • The waterproofing of Building on the roof has been exposed more underground or the other part of waterproofing than environmental factor(solar heat, UV, salt, acid rain, wind, temperature, snow, rain, etc.) or physical factor. So it must be have a waterproofing performance and it has a special technique for the maintaining of concrete durability. Therefore, exposed waterproof layer has to protected from UV, solar heat, rain and the outside environment also, to endurance durability methods spread face plate topcoat material on the waterproof layer. But, actuality faceplate waterproof layer of topcoat materials are unbearable to UV, solar heat and moisture etc. and it doesn't have adhesion with waterproof layer in the middle. So it happens to crack, separating and heaving etc. Therefore, in the study, we will suggest that using of the exposed roof waterproof layer topcoat materials test method manage rooftop waterproof layer for the durability and the stability.

  • PDF

염해를 받는 콘크리트 구조물의 내구수명 평가에 관한 연구 (A Study on Service Life Evaluation for Concrete Structures Subjected to Chloride Attack)

  • 송하원;백승우;변근주;성낙일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.229-232
    • /
    • 2004
  • In order to ensure the construction of sustainable reinforced concrete structures, durability evaluation of RC structures before construction should be carried out. In this paper, a service life evaluation technique using a safety factor determined by a reliability theory for RC structures subjected to chloride attack is proposed. The life safety factor and the service life evaluation .proposed in this paper can be applied consistently for the durability evaluation of recently developed Korean standard specification for durability of concrete structures which be used effectively for the evaluation before construction and maintenance for RC structures under chloride attack.

  • PDF

셀룰라아제 처리된 데님직물의 태에 관한 연구(제1보);주관적인 태 평가를 위한 척도개발 (The Assessment of Hand for Enzyme Hydrolyzed Denim fabrics(Part I))

  • 김경애;이미식;김정희
    • 한국의류학회지
    • /
    • 제23권8호
    • /
    • pp.1139-1148
    • /
    • 1999
  • This paper discussed the assessment of hand of denim fabrics finished by enzymatic hydrolysis. The semantic differential scale established using the database collected from university students. Analyzing the subjective rating by common factor analysis with oblimin rotation five factors expressing the hand were induced. Factor one was the surface property related to the surface roughness or softness Factor two was the durability which was related to the compactness and bearing strength Factor three was the sense of weight which was related to the thickness and weight. The moisture related properties and the sense of shape recovery were the forth and fifth factors respectively. the evaluations on the surface property weight and moisture related properties were similar by men and women However the shape recovery and the durability were evaluated differently. Surface and weight related properties were important factors judging the hand of fabrics by both group.

  • PDF

불포화폴리에스터 수지와 재생골재를 이용한 재생 폴리머 콘크리트의 강도 및 내구 특성 (Strength and Durability Properties of Recycled Polymer Concrete Using Unsaturated Polyester Resin and Recycled Aggregates)

  • 김영익;성찬용
    • 한국농공학회논문집
    • /
    • 제51권6호
    • /
    • pp.97-103
    • /
    • 2009
  • This study was performed to evaluate the strength and durability properties of recycled polymer concrete using unsaturated polyester resin and recycled aggregates. Unsaturated polyester resin, natural and recycled aggregates and fly ash were used. The mix proportions were determined to satisfy the requirement for the workability and slump according to aggregate sizes (5-10 and 5-25 mm) and unit binder contents (10% and 12%). Tests for the compressive and flexural strength, freezing and thawing and durability for 20% sulfuric solution were performed. The compressive and flexural strength of recycled polymer concrete were in the range of 85~97 MPa and 17.9~20.8 MPa, respectively. The strengths of recycled polymer concrete using recycled aggregate have similar or slightly decreased compared to polymer concrete using natural aggregate. After 300 cycles of freezing and thawing, weight decrease ratio and durability factor of recycled polymer concrete were in the range of 0.13~1.42% and 94~99, respectively.

전동식 조향 장치용 ECU 의 환경 내구 시험 시간 단축을 위한 설계 검증 시험 사양 변경 사례 (An Example of Modification of Design Validation Test Specification to Reduce the Environmental Durability Test Time of Electronic Control Unit for Motor-Driven Power Steering system)

  • 김태훈;강동영;정인승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1309-1313
    • /
    • 2008
  • This paper suggests an example of modification of the durability test specifications of electronic control unit for an automotive system in phase of design validation. The basic concept to redefine the specifications of durability test is based on the Arrhenius relationship for accelerated temperature test and the modified Coffin-Manson model for temperature cycle test. The ambient temperature of the powered-event durability test is increased to reduce the required test time of the current specification. Furthermore, the holding time between the events to cool down the temperature of the components is shortened and the resultant temperature rise affects the durability of the components. Thus, the acceleration factor due to the increased temperature range of temperature cycle is also estimated by the modified Coffin-Manson model.

  • PDF

초미세발포 플라스틱 기어에 관한 연구 (II) - 카운터프레셔 초미세발포 플라스틱 기어의 특성 - (Injection Molded Microcellular Plastic Gear (II) - Characteristics of the Counter Pressurized Microcellular Plastic Gear -)

  • 하영욱;;정태형
    • 대한기계학회논문집A
    • /
    • 제29권5호
    • /
    • pp.655-662
    • /
    • 2005
  • This paper investigates the improvement of accuracy and fatigue life of the developed counter pressurized microcellular gears of polyacetal. It is shown that the fatigue life and operational characteristics of the counter pressurized microcellular gears are more improved than conventional injection molded plastic gears by the dynamic gear durability test. For the cases of test sea.5. conventional injection molded sea.5(SGea.) and counter pressurized microcellular gears(CGear) are manufactured. Durability test is performed on both conventional lnjection molded gears and counter pressurized microcellular gears. Accuracy variation and operational characteristics on fatigue life, wear and tooth surface temperature of CGear and Scear are compared and represented. Operational characteristics of the proposed counter pressurized microcellular gears show a good result in this research. The durability limit of counter pressurized microcellular gears is also obtained, and represented by a function of unit load as well as by a function off-factor.

콘크리트 공극 분석을 위한 평면간격계수의 제안 (Proposal of Plane Spacing Factor for Analyzing Air Void System in Concrete)

  • 정원경;최성용;김성환;윤경구
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.39-47
    • /
    • 2005
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM are the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the plane spacing factor by calculation of simplicity. The plane spacing factor need two parameters that are air content and numbers of air voids in the hardened concrete. Those obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The plane spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

염해 환경에 노출된 RC 구조물의 내구성능설계를 위한 퍼지 추론 기반 환경영향지수의 산정 (Fuzzy Inference-based Quantitative Estimation of Environmental Affecting Factor For Performance-based Durability Design of RC Structure Exposed to Salt Attack Environment)

  • 도정윤;송훈;소승영;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.237-240
    • /
    • 2005
  • As a part of the effort for improving the durability design based on a set of the deem-to-satisfy specifications, it is important and primary to quantitatively identify the environmental impact to a target reinforced concrete structure. In this work, an effort is made to quantitatively calculate the environmental affecting factor with using a fuzzy inference that it indicates the severity of environmental impact to the exposed reinforced concrete structure or member. This system is composed of input region, output region and rule base. For developing the fuzzy inference system surface chloride concentration{chloride), cyclic degree of wet and dry(CWD), relative humidity(RH) and temperature (TEMP) were selected as the input parameter to environmental affecting factor(EAF) of output parameter. The Rules in inference engine are generated from the engineering knowledge and intuition based on some international code of practises as well as various researcher's experimental data. The devised fuzzy inference system was verified comparing the inferred value with the investigation data, and proved to be validated. Thus it is anticipated that this system for quantifying EAF is certain to be considered into the starting point to develop the performance-based durability design considering the service life of structure.

  • PDF