• Title/Summary/Keyword: duplex

Search Result 943, Processing Time 0.024 seconds

Bearing resistance design of stainless steel bolted connections at ambient and elevated temperatures

  • Cai, Yancheng;Young, Ben
    • Steel and Composite Structures
    • /
    • v.29 no.2
    • /
    • pp.273-286
    • /
    • 2018
  • In recent years, significant progress has been made in developing design rules for stainless steel members, while the investigation on bolted connections is relatively limited, in particular at elevated temperatures. In this paper, experimental and numerical investigations on stainless steel bolted connections at ambient and elevated temperatures from the literature were reviewed. Firstly, the research program that focused on structural behavior of cold-formed stainless steel (CFSS) bolted connections at elevated temperatures carried out by the authors were summarized. Over 400 CFSS single shear and double shear bolted connection specimens were tested. The tests were conducted in the temperature ranged from 22 to $950^{\circ}C$ using both steady state and transient state test methods. It is shown that the connection strengths decrease as the temperature increases in the similar manner for the steady state test results and the transient state test results. Generally, the deterioration of the connection strengths showed a similar tendency of reduction to those of the material properties for the same type of stainless steel regardless of different connection types and different configurations. It is also found that the austenitic stainless steel EN 1.4571 generally has better resistance than the stainless steel EN 1.4301 and EN 1.4162 for bolted connections at elevated temperatures. Secondly, extensive parametric studies that included 450 specimens were performed using the verified finite element models. Based on both the experimental and numerical results, bearing factors are proposed for bearing resistances of CFSS single shear and double shear bolted connections that subjected to bearing failure in the temperature ranged from 22 to $950^{\circ}C$. The bearing resistances of bolted connections obtained from the tests and numerical analyses were compared with the nominal strengths calculated from the current international stainless steel specifications, and also compared with the predicted strengths calculated using the proposed design equations. It is shown that the proposed design equations are generally more accurate and reliable than the current design rules in predicting the bearing resistances of CFSS (EN 1.4301, EN 1.4571 and EN 1.4162) bolted connections at elevated temperatures. Lastly, the proposed design rules were further assessed by the available 58 results of stainless steel bolted connections subjected to bearing failure in the literature. It is found that the proposed design rules are also applicable to the bearing resistance design of other stainless steel grades, including austenitic stainless steel (EN 1.4306), ferritic stainless steel (EN 1.4016) and duplex stainless steel (EN 1.4462).

Clinical Findings and Therapy of Ureteral Duplication in 61 Children (소아에서의 중복요관에 관한 임상적 고찰)

  • Yook Jin Won;Kim Ji Hong;Kim Pyung Kil;Han Sang Won
    • Childhood Kidney Diseases
    • /
    • v.2 no.2
    • /
    • pp.169-177
    • /
    • 1998
  • Purpose : Renal duplication is a common occurrence, and the range of ureteral and renal anomalies draining the two poles of the duplex kidney leads to a variety of clinical presentations. Method : A series of 61 children with duplicated systems was studied retrospectively who were admitted during last 12years. Results : Of the children $60.6\%$ were accompanied with urologic anomalies that required surgical treatment, and most children initially were presented with urinary tract infection. $42.6\%$ of children were either diagnosed incidentally during evaluation of other non-urologic disease or during follow-up evaluation of abnormal antenatal renal sonogram. Conclusion : From our point view, children with history of abnormal antenatal renal sonogram, or with symptoms such as urinary tract infection, hematuria, abdominal pain should be evaluated radiologially fully to confirm further abnormality and accompanied complications. And routine follow-up using abdominal ultrasonogram, VCUG, and urine culture should be used to prevent and detect early treatable complications.

  • PDF

Study on microstructure and mechanical properties of friction stir welded duplex stainless steel (마찰교반접합된 이상 스테인리스강의 미세조직 및 기계적 특성에 관한 연구)

  • Choi, Don-Hyun;Ahn, Byung-Wook;Yeon, Yun-Mo;Song, Keun;Jung, Seung-Boo
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.24-24
    • /
    • 2010
  • 마찰교반접합법은 특정한 회전수로 회전하는 용접 툴을 이용하여 접합하고자 하는 피접합재의 맞댄면에 삽입시킨 후 툴을 이동시키거나 혹은 시편을 견고하게 고정시킨 장치(backing plate)가 움직여 고상 상태에서 접합이 이루어진다. 알루미늄, 마그네슘 등 비교적 융점이 낮은 저융점 재료의 재료에 처음 적용이 되어 많은 연구가 활발히 진행되었고 타 용접방법에 비해 우수한 접합특성을 나타내었다. 최근 이러한 마찰교반접합은 이러한 저융점 재료를 넘어서 스틸, 타이타늄, 니켈 등과 같은 고융점 재료 등에 대한 적용이 늘어나고 있다. 마찰교반접합을 이용하여 이러한 고융점 재료의 접합 경우 내마모성 및 내열성 등의 내구성이 갖추어진 툴과 이러한 툴을 냉각시킬 수 있는 냉각 장치 등이 필요로 하나 경제적 측면이나 접합부의 우수한 특성 등을 고려 할 때 그 적용 및 발전 가능성이 매우 높다고 볼 수 있다. 2상 스테인레스 강은 금속 조직적으로 페라이트와 오스테나이트 상이 거의 1:1의 동등한 비율로 매우 미세하게 결합된 구조를 가지고 있다. 또한 이상 스테인레스 강은 각상의 개개의 특성에 기인하여 염소 분위기에서 응력부식 저항성이 우수하고, 공식과 틈부식에 대한 저항성이 매우 뛰어나다. 그리고 이상 스테인레스 강은 비교적 고가인 Ni이 일반 오스테나이트 스테인리스 강의 약 1/2의 수준으로 적게 포함이 되어 경제적인 이점을 지니고 있으며 또한 용접성이 좋아 산업계의 수요는 현재 점차 증가하고 있는 상황이다. 하지만 이러한 이상 스테인리스 강은 용접 후 페라이트 상의 조대화, 그리고 페라이트 상의 분율이 오스테나이트 상의 분율보다 높아지게 되어 용접부에서의 저온 인성 감소 및 내식성 저하 등의 문제가 발생하게 된다. 그리하여 용접 시 이러한 문제점을 해결하기 위해서는 입열량의 조절이 가장 필요로 하는 것으로 알려져 있다. 본 연구에서는 마찰교반용접을 이용하여 두께 3mm의 대표적인 이상 스테인리스 강인 SAF2205 스테인리스 강에 대해 맞대기 마찰교반접합을 실시하였다. 툴 회전속도를 변수로 하여 접합을 실시하였으며 접합 시 툴은 $Si_3N_4$ 툴을 사용하였다. 접합 후 외관상태 점검, 미세조직 관찰, 경도 및 인장강도 측정 등의 실험을 실시하였고, 이러한 결과를 이용하여 미세조직과 기계적 특성과의 관련성을 조사하였다.

  • PDF

A Design and Implementation of Application based on HTML5 of N-Screen Service (N-Screen Service를 위한 HTML5 기반의 Application 설계 및 구현)

  • Kim, Jeong-Jae;Seo, Joo-Hyun;Choi, Hyun-Woo;Lee, Jun-Ho;Kim, Jun-su;Cho, Kuk-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.671-674
    • /
    • 2012
  • Recently, depending on the development of smart devices, a variable services have been offered to meet user's convenience. Due to these advance, the needs of users are extremely being diversified and more specific. In that situation, the needs for the N-Screen system has been varied and gradually evolved. An existing N-Screen system that use the way of video streaming upload its multimedia contents to their own cloud server so that might take a long play-reaction time and the number of user is limited by the server's performance. Because of the web based protocol adopted by existing N-Screen system, there are many different problems like high delay, overhead and something caused by simplex data communications. Therefore, to solve the problems above, this study proposes an application based on HTML5. This application supports Video tag and Progressive download via HTML5 so that improves the play-reaction time for multimedia contents. This system can also get rid of the chronic problems such as an access limitation for lots of users as per video streaming encoding. Also, through web sockets, this study proposes a system that has lower delay than the existing system and communicates in full duplex to be able to link dynamically.

  • PDF

Performance Evaluation and Analysis of MIMO-IBFD Systems (MIMO-IBFD 시스템의 성능 평가 및 분석)

  • An, Changyoung;Kung, Kyung-Lok;Kim, Byeongjae;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.5
    • /
    • pp.531-538
    • /
    • 2016
  • In this paper, we have proposed MIMO-IBFD system that can transmit and receive multiple data stream at the same time in the single band, and analyze the system. We have confirmed that MIMO-IBFD system requires multiple RF cancellation and multiple Digital cancellation techniques. In simulation, we have analyzed characteristic of received signal on MIMO-IBFD system, and evaluate system performance of conventional $2{\times}2$ MIMO system and MIMO-IBFD system. As simulation results, we have confirmed that MIMO-IBFD system can transmit and receive multiple data stream at the same time in the single band by using multiple RF and digital cancellation techniques. Additionally, we have confirmed that BER performance of $2{\times}2$ MIMO-IBFD system with low-level QAM modulation is similar to performance of $2{\times}2$ MIMO system, and BER performance of $2{\times}2$ MIMO-IBFD system with high-level QAM modulation is degraded in comparison with $2{\times}2$ MIMO system with high-level QAM modulation. We can confirm that MIMO-IBFD system requires high level self-interference cancellation technique in order to use high level modulation.

A Design of SPI-4.2 Interface Core (SPI-4.2 인터페이스 코어의 설계)

  • 손승일
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1107-1114
    • /
    • 2004
  • System Packet Interface Level 4 Phase 2(SPI-4.2) is an interface for packet and cell transfer between a physical layer(PHY) device and a link layer device, for aggregate bandwidths of OC-192 ATM and Packet Over Sonet/SDH(POS), as well as 10Gbps Ethernet applications. SPI-4.2 core consists of Tx and Rx modules and supports full duplex communication. Tx module of SPI-4.2 core writes 64-bit data word and 14-bit header information from the user interface into asynchronous FIFO and transmits DDR(Double Data Rate) data over PL4 interface. Rx module of SPI-4.2 core operates in vice versa. Tx and Rx modules of SPI-4.2 core are designed to support maximum 256-channel and control the bandwidth allocation by configuring the calendar memory. Automatic DIP4 and DIP-2 parity generation and checking are implemented within the designed core. The designed core uses Xilinx ISE 5.li tool and is described in VHDL Language and is simulated by Model_SIM 5.6a. The designed core operates at 720Mbps data rate per line, which provides an aggregate bandwidth of 11.52Gbps. SPI-4.2 interface core is suited for line cards in gigabit/terabit routers, and optical cross-connect switches, and SONET/SDH-based transmission systems.

A Study of Thermo-Mechanical Analysis for the Design of High Pressure Piping System for Natural Gas Fuel Vessel (천연가스 연료선박의 고압 이중 배관 설계를 위한 열-구조 해석에 관한 연구)

  • Park, Seong-Bo;Sim, Myung-Ji;Kim, Myung-Soo;Kim, Jeong-Hyeon;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.425-431
    • /
    • 2015
  • LNG (liquefied natural gas) is considered the best alternative eco-fuel, and many studies on the LNG fuel system have been performed to use LNG as the fuel for ships. For the LNG fuel supply system, natural gas transfers from the vaporizer to the engine in the gaseous state with a temperature of $50^{\circ}C$ and a pressure of 35MPa. Therefore, a structural safety evaluation of the double-walled pipelines considering thermal load is essential. In this article, an uniaxial tensile test for super duplex stainless steel, material for double-walled pipe, according to the annealing time was carried out to analyze the thermal effect. In addition, thermo-structural analysis of the high temperature-high pressure double-walled pipe with fixed supports that are now used widely was carried out to evaluate the structural safety. To minimize stress concentration of the connection point between the support and inner pipe, the shapes of the new type support that can slip through inner pipe were proposed, and the supports which has best structural performance was selected using the results from the thermo-structural analyses of new supports and an analysis of the whole double-walled pipeline was performed to ensure structural safety. These results can be used as a database for the design of double-walled pipelines and sliding support.

Real-Time DSP Implementation of IMT-2000 Speech Coding Algorithm (IMT-2000 음성부호화 알고리즘의 실시간 DSP 구현)

  • Seo, Jeong-Uk;Gwon, Hong-Seok;Park, Man-Ho;Bae, Geon-Seong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.3
    • /
    • pp.304-315
    • /
    • 2001
  • In this paper, we peformed the real-time implementation of AMR(Adaptive Multi-Rate) speech coding algorithm which is adopted for IMT-2000 service using TMS320C6201, i.e., a Texas Instrument´s fixed-point DSP. With the ANSI C source code released from ETSI, optimization is performed to make it run in real-time with memory as small as possible using the C compiler and assembly language. Implemented AMR speech codec has the size of 32.06 kWords program memory, 9.75 kWords data RAM memory, and 19.89 kWords data ROM memory. And, The time required for processing one frame of 20 ms length speech data is about 4.38 ms, and it is short enough for real-time operation. It is verified that the decoded result of the implemented speech codec on the DSP is identical with the PC simulation result using ANSI C code for test sequences. Also, actual sound input/output test using microphone and speaker demonstrates its proper real-time operation without distortions or delays.

  • PDF

Development of ultrafine grained silicon carbide by spark plasma sintering (스파크 플라즈마 소결에 의한 초미세 결정립 탄화규소의 개발)

  • 조경식;이광순;백성호;이상진
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.4
    • /
    • pp.176-181
    • /
    • 2003
  • Rapid densification of a SiC powder with additive 0.5 wt% $B_4$C was conducted by spark plasma sintering (SPS). The unique features of the process are the possibilities of using very fast heating rate and short holding time to obtain fully dense materials. The heating rate and applied pressure were kept to be $100^{\circ}C$/min and 40 MPa, while sintering temperature and soaking time varied to 1800, 1850, 1900 and $1950^{\circ}C$ and 10, 20 and 30 min, respectively. All of the SPS-sintered specimens at $1950^{\circ}C$ reached near-theoretical density. The XRD found that 3C-to-6H transformation at $1850^{\circ}C$. The microstructures of the rapidly densified SiC ceramics consisted of duplex microstructure with ultrafine equiaxed grains under 2 $\mu\textrm{m}$ and elongated grains of 0.5∼2 $\mu\textrm{m}$ wide, length 3∼10 $\mu\textrm{m}$. The biaxial strength increased with the increase of sintering time. Strength of 392.7 MPa was obtained with the fully densified specimen sintered at $1950^{\circ}C$ for 30 min, in agreement with the general tendency that strength increases with decreases pore. On the other hand, the fracture toughness shows the value of 2.17∼2.34 MPa$.$$m^{1/2}$ which might be due to the transgranular fracture mode.

Prevention Effects of Graduated Compression Stockings and Intermittent Pneumatic Compression on Deep Vein Thrombosis in SICU Patients: Pilot Study (항혈전스타킹과 간헐적공기압박기 적용이 중환자의 심부정맥혈전 발생 예방에 미치는 효과: 예비조사)

  • Kim, Hwasoon;Cho, Ok Min;Kim, Ji Sun;Jang, Hai Ok;Kim, Yeo Kyeong;Kim, Seol Hee;Min, Hyo Nam;Kwak, Kyung Sun;Hong, Kee Chun;Kim, Jang Yong;Chung, Joonho
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.22 no.3
    • /
    • pp.249-257
    • /
    • 2015
  • Purpose: The purpose of this pilot study was to investigate the effects of mechanical interventions for deep vein thrombosis (DVT) prophylaxis in surgical intensive care unit (SICU) patients. Methods: The participants were assigned to the intermittent pneumatic compression (IPC) and graduated compression stocking (GCS) intervention. Patients who met the criteria were selected for comparison from our previous study. Data for 140 patients were included in the final analysis. Results: The mean age was 57.5 (${\pm}15.7$) and 61.4 % were men. About forty-seven percent of the participants were 61 years or over. In the second duplex scan, 3, 2 and 1 critically ill patients developed deep vein thrombosis in the control, GCS, and IPC groups, respectively. Incidences of DVT were 6.0%, 5.0%, and 2.0% for the control, GCS, and IPC groups, respectively. This difference was not significant. Relative risks of no intervention were 3.0 and 1.2 compared with IPC and GCS application. There were no significantly different variables among the three groups before the intervention except for diagnosis on admission. Conclusion: Although it may difficult to conclude that mechanical prophylaxis effectively prevents DVT among SICU patients because there was no statistical significance in this study, but incidence rates among the three groups differed greatly. The findings reveal that further study should be conducted with larger samples and randomized controlled trial for SICU patients.