• Title/Summary/Keyword: dual-rate

Search Result 827, Processing Time 0.031 seconds

Parallel Integration for Real-Time Simulation (실시간 시뮬레이션을 위한 병렬적분)

  • Lee, W.S.;Samson, J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.106-115
    • /
    • 1994
  • A parallel integration approach is proposed for real-time simulation of controlled mechanical systems. The proposed approach, which employs the dual-rate integration method in a parallel computing environment, is developed to deal with stiffness and high frequency characteristics of the controlled mechanical systems effectively. Numerical experiments are performed to demonstrate the effectiveness of the approach in shared memory multiprocessors, Alliant FX/8 and Alliant FX/80.

  • PDF

Effects of porcine circovirus type 2 on the pathogenesis of porcine epidemic diarrhoea virus infection in piglets - I. Serological result, FA test and RT-PCR - (포유자돈에서 돼지써코바이러스 2형이 돼지유행성설사 바이러스 감염에 미치는 영향 - I. 혈청학적 결과, 형광항체검사 및 RT-PCR 검사 -)

  • Jin, Wen;Kim, Yeong-Hun;Han, Jeong-Hee
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.3
    • /
    • pp.177-187
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of a subsequent infection of PCV2 on piglets with PEDV. The results obtained were as follows: Antibodies against PCV2 and PEDV were detected at 24, 36, 48, 60 and 72h postinfection. And the antibody titers of alone infections with PEDV were gradually reduced and increased from 60 hpi to 72 hpi. Whereas, the antibody titers of dual infections with PCV2 and PEDV were gradually reduced all the time. PEDV antigens were detected at 24, 36, 48, 60 and 72 hpi, being seen almost exclusively in feces and small intestines from PEDV-infected piglets and PCV2-coinfected piglets. The detection rate of PEDV in feces and jejunum tissues by RT-PCR were 94.9% and 91.1% in dual infections and 87.1% and 83.6% in alone infections with PEDV, respectively. In dual infected piglets, significantly more PEDV antigens were detected in the feces and small intestines tissues at 24 hpi (P<0.05) than in the same feces and tissues of the alone infected piglets. Thereafter, at 72 hpi significantly more PEDV antigens (P<0.05) was detected in the jejunal tissues of the dual infected piglets with than of alone PEDV-infected piglets. The detection rate of PEDV antigen in the duodenum, jejunum and ileum by IFA were 91.3%, 91.3% and 83.3% in dual infected piglets and 75.0%, 83% and 75% in alone infected piglets, respectively. Intense and specific fluorescence signals were more often seen within jejunal villous enterocytes in dual infected piglets than alone infected piglets.

Effect of a dual trigger on oocyte maturation in young women with decreased ovarian reserve for the purpose of elective oocyte cryopreservation

  • Kim, Se Jeong;Kim, Tae Hyung;Park, Jae Kyun;Eum, Jin Hee;Lee, Woo Sik;Lyu, Sang Woo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.47 no.4
    • /
    • pp.306-311
    • /
    • 2020
  • Objective: The aim of this study was to determine whether co-administration of a gonadotropin-releasing hormone (GnRH) agonist and human chorionic gonadotropin (hCG) for final oocyte maturation improved mature oocyte cryopreservation outcomes in young women with decreased ovarian reserve (DOR) compared with hCG alone. Methods: Between January 2016 and August 2019, controlled ovarian stimulation (COS) cycles in women (aged ≤35 years, anti-Müllerian hormone [AMH] <1.2 ng/mL) who underwent elective oocyte cryopreservation for fertility preservation were retrospectively analyzed. Results: A total of 76 COS cycles were triggered with a GnRH agonist and hCG (the dual group) or hCG alone (the hCG group). The mean age and serum AMH levels were comparable between the two groups. The duration of stimulation, total dose of follicle-stimulating hormone used, and total number of oocytes retrieved were similar. However, the number of mature oocytes retrieved and the oocyte maturation rate were significantly higher in the dual group than in the hCG group (p=0.010 and p<0.001). After controlling for confounders, the dual-trigger method remained a significant factor related to the number of mature oocytes retrieved (p=0.016). Conclusion: We showed improved mature oocyte collection and maturation rate with the dual triggering of oocyte maturation in young women with DOR. A dual trigger appears to be more beneficial than hCG alone in terms of mature oocyte cryopreservation for young women with DOR.

Characteristics of Depth Filtration for Various Filter-Bed Configurations (심층여과지의 여층구성에 따른 여과특성 비교)

  • An, Jong-Ho;Yun, Jae-Heung
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.459-472
    • /
    • 2001
  • The objective of this study is to evaluate the filtration efficiency of deep-bed filters by comparing to single and dual media filters. Pilot-plant tests using four-filter columns were conducted for the comparison of head loss development and filtered water quality. The dual-media filter showed greater initial head loss, but less rate of head-loss development than those of the coarse-sand-0deep-bed filters. For 180 m/day of filtration rate, the dual-media filter produces larger unit production rate by 30-40%, and the turbidities of filtered water were below 0.1 NTU. The initial breakthrough could be effectively controlled by the dual-media filter rather than coarse-sand-deep-bed filters.

  • PDF

Discrete-Time Queuing Analysis of Dual-Plane ATM Switch with Synchronous Connection Control

  • Choi, Jun-Kyun
    • ETRI Journal
    • /
    • v.19 no.4
    • /
    • pp.326-343
    • /
    • 1997
  • In this paper, we propose an ATM switch with the rate more than gigabits per second to cope with future broadband service environments. The basic idea is to separate the connection control flow from the data information flow inside the switch. The proposed switch has a dual-plane switch matrix with the synchronous control algorithm. The queuing behaviors of the proposed switch are shown by the discrete-time queuing analysis. Numerical analyses are taken both in the non-blocking crossbar switch and the banyan switch with internal blocking. Results show that a proposed dual-plane $16{\times}16$ switch would have the acceptable performance with maximum throughput of about 95 percent.

  • PDF

The Effects of 3.5% NaCl Aqueous Solution Temperature on the Corrosion Fatigue Fracture of Dual phase steel (3.5% NaCl 수용액의 온도변화가 복합조직강의 부식피로파괴에 미치는 영향)

  • 오세욱;도영문;박수영;김재철;김광영
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.140-147
    • /
    • 1992
  • Corrsion fatigue test was performed under rotated bending in 3.5% NaCl aqueous solution having a temperature from 278.deg.K in order to investigate the effects of aqueous solution remperature on the corrosion fatigue fracture of raw material steel(SS41) and dual phase steel that was produced from SS41 by a series of heat treatment. Corrosion fatigue life decreases remarkably with increase in solution temperature or with decrease in stress level. The corrosion fatigue life and the crack propagation rate at 303.deg.K show the similar behaviors with those at 318.deg.K, which is assumed to be caused by concentration polarization phenamena. The number and the lengths of microcracks increase with increase in solution temperature, so they lead to the decrease in corrosion fatigue life.

  • PDF

Multi-User Transmission Exploiting Multiple Dual-Polarized Antennas (이중 편파 다중 안테나를 이용한 다중 사용자 전송)

  • Shin, Changyong;Park, Youn Ok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.12
    • /
    • pp.774-776
    • /
    • 2014
  • In this paper, we propose a multiple dual-polarized antenna system for multi-user transmission in line-of-sight (LoS) dominant channel environments. By exploiting space and polarization resources efficiently, the proposed system achieves a higher sum rate than the existing multi-user multiple input multiple output (MU-MIMO) system with uni-polarized antennas.

Channel Coding-Aided Multi-Hop Transmission for Throughput Enhancement

  • Hwang, Inchul;Wang, Hanho
    • International Journal of Contents
    • /
    • v.12 no.1
    • /
    • pp.65-69
    • /
    • 2016
  • Wireless communication chipsets have fixed transmission rate and communication distance. Although there are many kinds of chipsets with throughput and distance purpose, they cannot support various types of wireless applications. This paper provides theoretic research results in order to support various wireless applications requiring different throughput, delayed quality-of-service (QoS), and different communication distances by using a wireless communication chipset with fixed rate and transmission power. As a performance metric, the probability for a data frame that successfully receives at a desired receiver is adopted. Based on this probability, the average number of transmission in order to make a successful frame transmission is derived. Equations are utilized to analyze the performance of a single-hop with channel coding and a dual-hop without error correction matter transmission system. Our results revealed that single-hop transmission assisted by channel coding could extend its communication distance. However, communication range extending effect of the single-hop system was limited. Accordingly, dual-hop transmission is needed to overcome the communication distance limit of a chipset.

A 2.7Gbps & 1.62Gbps Dual-Mode Clock and Data Recovery for DisplayPort in $0.18{\mu}m$ CMOS

  • Lee, Seung-Won;Kim, Tae-Ho;Lee, Suk-Won;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.14 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • This paper describes a clock and data recovery (CDR) circuit that supports dual data rates of 2.7Gbps and 1.62Gbps for DisplayPort standard. The proposed CDR has a dual mode voltage-controlled oscillator (VCO) that changes the operating frequency with a "Mode" switch control. The chip has been implemented using $0.18{\mu}m$ CMOS process. Measured results show the circuit exhibits peak-to-peak jitters of 37ps(@2.7Gbps) and 27ps(@1.62Gbps) in the recovered data. The power dissipation is 80mW at 2.7Gbps rate from a 1.8V supply.

Effects of Dual-Coagulant Performance (이중응집이 응집공정에 미치는 영향)

  • Kim, Hee-Geun;Moon, Byung-Hyun;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.92-97
    • /
    • 2005
  • This research is to investigate the effect of the dual coagulant using inorganic coagulants($AICl3{\cdot}6H2O$) and polymer on the coagulant process. Jar-test was conducted by using Kaolin injected raw water. PDA(Photometric Dispersion Analyzer) equipment in order to analyze the size of the particles and the characteristics of the shapes. The change in the rate of sample ores' residual deposited after coagulants were also compared. According to the result derived from this experiment, the concentration of inorganic coagulant reduced 50% and the residual was lower by using dual coagulants compared to using single coagulant. However the dual coagulant required sufficient mixing time, and affected particle characteristics, with the effect of the injection order of coagulants, the simultaneous injection of inorganic coagulant and polymer showed the most effective in the particle removal.