• Title/Summary/Keyword: dual system

Search Result 2,715, Processing Time 0.03 seconds

Development of Space Divided PE-ALD System and Process Design for Gap-Fill Process in Advanced Memory Devices (차세대 메모리 디바이스Gap-Fill 공정 위한 공간 분할 PE-ALD개발 및 공정 설계)

  • Lee, Baek-Ju;Hwang, Jae-Soon;Seo, Dong-Won;Choi, Jae-Wook
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.3
    • /
    • pp.124-129
    • /
    • 2020
  • This study is for the development of high temperature ALD SiO2 film process, optimized for gap-fill process in manufacturing memory products, using a space-divided PE-ALD system equipped with an independent control dual plasma system and orbital moving unit. Space divided PE-ALD System has high productivity, and various applications can be applied according to Top Lid Design. But space divided ALD system has a limitation to realize concentric deposition map due to process influence due to disk rotation. In order to solve this problem, we developed an orbit rotation moving unit in which disk and wafer. Also we used Independent dual plasma system to enhance thin film properties. Improve productivity and film density for gap-fill process by having deposition and surface treatment in one cycle. Optimize deposition process for gap-fill patterns with different depths by utilizing our independently controlled dual plasma system to insert N2and/or He plasma during surface treatment, Provide void-free gap-fill process for high aspect ratio gap-fill patterns (up to 50:1) with convex curvature by adjusting deposition and surface treatment recipe in a cycle.

Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite (이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구)

  • Lee, Jun-Bong;Park, Jong-Duk;Kwon, Su-Mi;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

비행체 구조시험 장비의 교정 확인 방법 개발

  • Chae, Dong-Chul;Kim, Sung-Chan;Hwang, Gui-Chul;Shim, Jae-Yeul
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.21-26
    • /
    • 2005
  • In airframe structural tests, a control system which has many control channels and a data acquisition system which has many data acquisition channels are used. The more it is used many channels in airframe structural test, the more hardware resources are added in test system. Before test load is applied in test article, test engineer must check test system and components. Therefore, many problems which be likely to happen to system can be minimized. The checking method of test system and components is calibration verification. In this paper, it is described that calibration verification concept and method in relation to airframe structural test controller components.(MTS Aero90 Multifunction Input Output Processor and 497.22 Dual DC Conditioner)

  • PDF

Analysis of Irradiation and Power per Each Seasons of Photovoltaic Systems (태양광 발전시스템의 계절별 일사량과 전력량 분석)

  • Kim, Seok-Gon;Hwang, Jun-Won;Lee, Ying;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.43-45
    • /
    • 2009
  • In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than 80$[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation Power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study, the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.

  • PDF

Performance Analysis of Operation Strategy of Dual Virtual Cell-based System under The Overlay Convergent Networks of Cognitive Networking (인지 네트워킹 기반 중첩 융합 네트워크에서 이중 가상 셀 운영방안의 성능분석)

  • Choi, Yu-Mi;Kim, Jeong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6B
    • /
    • pp.483-488
    • /
    • 2012
  • With the fast growing data traffic, the performance of the convergent overlay network environment under the cognitive networking environment is crucial for the implementation of the efficient network structure. In order to achieve high capacity and reliable link quality in wireless communication of the overlay convergent networks with the cognitive networking based on the advanced capability of the mobile terminal, a Distributed Wireless Communication System (DWCS) can provide the capability of ambient-aware dual cell system's operation. This paper has considered virtual cell: the Dual Virtual Cell (DVC), and also proposes DVC employment strategy based on DWCS network. One is the Active Virtual Cell which exists for user's actual data traffic and the other is the Candidate Virtual Cell which contains a set of candidate antennas to protect user's link quality from performance degradation or interruption. The considered system constructs DVC by using cognitive ability of finding useful virtual signals. Also, for multi-user high-rate data transmission, the DWCS system exploits Space-Time Trellis Codes. The effects of changing environments on the system performance has been investigated thereafter.

Mobile monitoring system of the Dual LED marine lantern (이중 LED 등명기의 휴대용 모니터링 시스템)

  • Ye, Seong-Hyeon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1948-1954
    • /
    • 2014
  • Advances in IT technology and modernization of AtoN(Aids to Navigation) facility has increased the unmanned operation of AtoN. However, in AtoN facilities, accessibility is low and it is not able to perform maintenance on the bad weather at the time. In connection with this, in this paper, by applying the protocol of the enhanced dual LED marine lantern, we implemented the short-range monitoring system for a mobile terminal. System implemented in this paper can be carried out confirm the operation status, inspection or control of the dual LED marine lantern at a short distance. Also, it is possible to reduce maintenance costs and prevent accidents during inspection of AtoN. At the same time, it enables the operation test easily without disassembling the product, effective AtoN operation is possible. We tested the system that has been implemented using prototype of the LED marine lantern and confirmed state informations and controlled the behavior of the system in real time.

Dual task interference while walking in chronic stroke survivors

  • Shin, Joon-Ho;Choi, Hyun;Lee, Jung Ah;Eun, Seon-deok;Koo, Dohoon;Kim, JaeHo;Lee, Sol;Cho, KiHun
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.134-139
    • /
    • 2017
  • Objective: Dual-task interference is defined as decrements in performance observed when people attempt to perform two tasks concurrently, such as a verbal task and walking. The purpose of this study was to investigate the changes of gait ability according to the dual task interference in chronic stroke survivors. Design: Cross-sectional study. Methods: Ten chronic stroke survivors (9 male, 1 female; mean age, 55.30 years; mini mental state examination, 19.60; onset duration, 56.90 months) recruited from the local community participated in this study. Gait ability (velocity, paretic side step, and stride time and length) under the single- and dual-task conditions at a self-selected comfortable walking speed was measured using the motion analysis system. In the dual task conditions, subjects performed three types of cognitive tasks (controlled oral word association test, auditory clock test, and counting backwards) while walking on the track. Results: For velocity, step and stride length, there was a significant decrease in the dual-task walking condition compared to the single walking condition (p<0.05). In particular, higher reduction of walking ability was observed when applying the counting backward task. Conclusions: Our results revealed that the addition of cognitive tasks while walking may lead to decrements of gait ability in stroke survivors. In particular, the difficulty level was the highest for the calculating task. We believe that these results provide basic information for improvements in gait ability and may be useful in gait training to prevent falls after a stroke incident.