• 제목/요약/키워드: drying shrinkage cracking

검색결과 81건 처리시간 0.031초

알파반수석고를 활용한 바닥용 건조 모르타르의 수축변형 특성에 관한 실험적 연구 (Experimental study on Properties of Dry Shrinkage Deformation of Floor Dry-mortar with Alpha-hemihydrate Gypsum)

  • 김래환;김규용;이보경;김정현;한상휴;최경철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.158-159
    • /
    • 2014
  • In general, the shrinkage occurring in the floor mortar is large the influence by the dry shrinkage. In order to reduce the cracks occurring in the floor mortar, studies of physical methods are often performed, but these methods is difficult to prevent cracking of the floor mortar essentially. Therefore, in this study, the dry shrinkage properties of floor mortar of gypsum and red clay type using alpha-hemihydrate gypsum had been evaluated. The experimental variables were cement mortar(CM), gypsum mortar(GM), red-clay mortar(RM), the evaluation items was conducted experiment to evaluate the setting time, the compressive strength, drying shrinkage cracks, the dry shrinkage. As a result, it was confirmed that condensation time of GM is shorter that that of CM, and GM satisfied the compressive strength of the floor mortar standard. Also shrinkage deformation of GM reduced more than the CM.

  • PDF

팽창재와 팽윤제가 혼입된 고로슬래그 콘크리트 Mock-up의 균열 저감 성능평가 (Mock-up Crack Reduction Performance Evaluation of Blast Furnace Slag Concrete Mixed with Expansive and Swelling Admixture)

  • 윤상혁;최원영;전찬수
    • 한국건설순환자원학회논문집
    • /
    • 제11권4호
    • /
    • pp.552-559
    • /
    • 2023
  • 본 연구는 팽창성 및 팽윤성 혼화제를 혼입한 고로슬래그 콘크리트의 균열 저감 성능 평가를 목적으로 한다. 기본 성능 실험으로 고로슬래그미분말(BFS), 칼슘설포알루미네이트(CSA), 벤토나이트, 하이드록시프로필 메틸셀룰로오스(HPMC) 등 다양한 혼입물을 사용하여 수행한 결과 벤토나이트가 HPMC에 비해 우수한 성능을 나타내었다. 이후, 혼입률에 따른 균열 및 건조수축 평가를 위해 MOCK-UP 테스트를 실시하였다. 그 결과, 벤토나이트와 소량의 인산칼슘을 첨가하였을 때 건조수축이 감소되어 균열이 저감 되었다. 특히, 30 %의 BFS, 1 %의 벤토나이트, 1 %의 인산칼슘으로 구성된 시멘트 혼합물이 균열이 없는 최적의 성능을 보였다. BFS 콘크리트가 지속적인 팽창 활동에 의하여 수축을 보상하는데 기여할 것으로 판단되며 현장 적용에 사용될 수 있을 것이다.

합성거더교 초기재령 고강도 콘크리트 바닥판의 균열 제어 (Crack Control of Early-Age High Strength Concrete Deck in Composite Bridge)

  • 배성근;김세훈;정상균;차수원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.493-496
    • /
    • 2008
  • 합성형교량의 바닥판 횡방향균열은 재료, 설계, 시공 등 다양한 요인에 의하여 영향을 받으며, 초기재령 콘크리트 바닥판 균열에 영향을 미치는 주요인자는 온도 및 수축변형에 기인한 것으로 알려져있다. 온도의 영향은 수화열과 복사열에 모두 영향을 받으며 일반적으로 보통강도콘크리트가 사용되는 바닥판은 건조수축, 고강도콘크리트 바닥판은 자기수축의 영향을 주로 받게 된다. 합성형교량을 범용 유한 요소 구조 해석 프로그램을 이용하여 수화열 및 복사열에 의한 온도응력, 자기 및 건조수축응력 해석을 수행하고, 이를 통하여 합성형교량 바닥판 콘크리트에서 발생한 균열의 원인을 규명하고자 한다. 균열 원인 분석으로 도출된 결과를 토대로 변수해석(parametric study)을 수행하여 향후 시공되는구조물의 균열제어대책을 제시하고자 한다.

  • PDF

차수벽 콘크리트의 균열제어 및 성능향상에 관한 연구 (Control of Crack and Enhanced Durability Performance of Face Slab Concrete)

  • 임정열;정우성;김완영;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.537-540
    • /
    • 2003
  • The effects of substituting cement with fly ash(10%, 15%, 20%) and different fiber addition(polypropylene, cellulose, poly vinyl alcohol), on the control of microcrack and enhanced durability performance of face slab concrete in CFRD was studied experimentally It was conducted experiments of plastic shrinkage of mortar and concrete, and drying shrinkage of concrete. Also, durability test were carried out the chloride permeability, abrasion resistance and freeze-thaw repetition. Through the experimental results, it was concluded that ploy vinyl alcohol fiber containing concrete was the most effective mixture in control of cracking and durability.

  • PDF

양생조건에 따른 플라이애쉬 콘크리트 균열특성에 미치는 영향 (The effect of curing conditions on the cracking properties of flyash concrete)

  • 박종화;이만익;남재현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.825-828
    • /
    • 2006
  • In this paper, experimental studies are performed to find out properties of crack according to the change of curing conditions of flyash concrete. To study the effect of curing conditions on flyash concrete, slump, bleeding, air content and hydration temperature of fresh concrete are measured according to various curing conditions. In addition, the effect of caring conditions on compressive strength, tensile strength and Plastic drying shrinkage cracking of hardened concrete is also considered.

  • PDF

팽창재와 수축저감제 사용 고성능 콘크리트의 내구성 평가 (Evaluation on the Durability of High Performance Concrete Used Expansive Additive and Shrinkage Reducing Agent)

  • 고경택;박정준;강수태;이종석;김도겸;김성욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.818-821
    • /
    • 2004
  • Generally, the high performance concrete of drying cracking and autogenous shrinkage are tend to be increased. In the previous study, it was found that the using method in combination with expansive additive and shrinkage reducing agent was more effective than the separtely using method of that. This study is to investigated the durability of high performance concrete using expansive additive and shrinkage reducing agent. Test results showed that the high performance concrete using expansive additive and shrinkage reducing agent had very good not only the durability performance such as salt injury, carbonation, resistance to freezing-thawing and permeability but also the resistance to shrinkage.

  • PDF

전력구 콘크리트 구조물 적용을 위한 알파형 반수석고 치환 콘크리트의 역학적 특성 (Mechanical Properties of Alpha-Calcium Sulfate Hemihydrate Replaced Concrete for Application to Box Culvert Power Transmission)

  • 신경수;김규용;성길모;우상균;추인엽;이보경
    • 한국건축시공학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2019
  • 본 연구에서는 전력구 콘크리트 구조물에서 발생하는 균열저감을 위해 알파형 반수석고를 치환한 콘크리트의 역학적 특성을 평가하였다. 알파형 반수석고의 치환율은 0, 6, 9, 12, 15%로 설정하여, 응결시간, 압축강도, 건조수축을 측정하였으며, 미세구조 및 결정구조의 분석을 실시하였다. 실험 결과, 알파형 반수석고의 치환율이 증가할수록 응결시간이 단축되었으며, 압축강도가 저하되는 경향을 확인하였다. 한편, 알파형 반수석고를 15% 치환할 경우 보통포틀랜드시멘트 콘크리트에 비해 건조수축이 약 60% 저감되는 효과가 나타났다. 따라서, 전력구 콘크리트 구조물에 알파형 반수석고를 치환한 콘크리트를 적용할 경우 균열저감 성능이 향상될 것으로 판단되며, 압축강도의 개선은 필요할 것으로 판단된다.

초고강도 콘크리트의 수축 균열 특성 및 구속도 평가 (Evaluation of Shrinkage Cracking Characteristics and Degree of Restraint for Ultra-High-Strength Concrete)

  • 류두열;민경환;양준모;윤영수
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.641-650
    • /
    • 2010
  • 콘크리트의 수축으로부터 발생하는 구속응력은 균열을 유발하고, 그에 따라 황산염 및 염화이온의 침투로 인한 철근의 부식으로 인해 콘크리트 구조물의 내구성을 저하시킨다. 특히, W/B가 감소할수록 균열 발생 가능성이 크며, 따라서 고강도 콘크리트(HSC), 초고강도 콘크리트(UHSC)의 수축 및 균열 거동의 정확한 이해와 평가가 필요하다. 하지만, 기존의 비구속 수축 실험은 콘크리트의 강도발현, 응력의 이완, 균열강도 및 구속도 등을 고려할 수 없으며, 균열 발생에 영향을 미치는 수축량의 평가에 한계가 있었다. 따라서 이 연구에서는 비구속 수축실험과 구속 수축실험(ring-test)을 통하여 W/B(30, 25, 16%) 및 혼화재에 따른 HSC, UHSC의 수축, 균열 거동을 평가하였다. 실험 결과, 자기수축 및 총 건조수축은 W/B가 클수록, 플라이애쉬(FA) 및 고로슬래그미분말(BFS)의 치환율이 증가할수록 감소하는 것으로 나타났으며, W/B의 증가 및 콘크리트 두께의 증가, FA의 혼입은 균열 발생을 효과적으로 억제하는 것으로 나타났다.

초속경 및 일반시멘트를 이용한 라텍스개질 콘크리트의 건조수축 특성 (Drying Shrinkage Properties of Latex Modified Concrete with Ordinary Cement and Rapid-Setting Cement)

  • 윤경구;정원경;김성환;이주형
    • 콘크리트학회논문집
    • /
    • 제15권1호
    • /
    • pp.95-101
    • /
    • 2003
  • 상대적으로 큰 비표면적으로 인해 야기될 수 있는 건조수축균열은 보통 포틀랜드시멘트를 사용한 라텍스개질 콘크리트(LMC) 및 초속경 시멘트를 사용한 라텍스개질 콘크리트(RSLMC) 덧씌우기에서 주요 관심사항이다. 우리나라에서는 LMC와 RSLMC의 현장 적용을 위해 강도와 내구특성 측면에서 활발히 연구되어 왔으나 건조수축특성에 관한 연구는 전무한 상태이다. 따라서, 본 논문의 목적은 LMC와 RSLMC의 건조수축특성에 관하여 시멘트 종류(보통 포틀랜드 시멘트, 초속경시멘트), 라텍스 혼입률(0, 5, 10, 15, 20%)을 주요 실험 변수로 하여 연구하고자 하였다. 양생방법으로는 60%의 상대습도와 $20^{\circ}C$의 온도로 하였으며, 건조수축용 시편은 디지털 Demec 게이지로 측정하였다. 실험 결과를 통하여 LMC와 RSLMC의 건조수축량은 OPC와 RSC보다 상당히 감소되는 것으로 나타났다. 이것은 콜로이드같은 라텍스의 특성이 수분 증발을 억제함으로써 향상되는 보습성과 라텍스 필름막에 의한 시멘트 수화물과 골재간의 상호연결작용으로 기인되는 것으로 판단된다.

양생 조건이 콘크리트의 체적 변화에 미치는 영향 (Influence of Curing Conditions on Volumetric Changes in Concrete)

  • 이광명;선우주연;이회근
    • 콘크리트학회논문집
    • /
    • 제18권3호
    • /
    • pp.331-338
    • /
    • 2006
  • 본 연구에서는 서로 다른 양생 조건하에서 W/C가 0.32~0.50인 콘크리트의 체적 변화를 실험을 통해 조사하였다. 콘크리트의 팽창뿐만 아니라 자기수축 및 건조수축을 측정하기 위해 4개의 서로 다른 양생 방법이 적용되었다. 밀봉을 통하여 수분 증발을 억제한 양생(조건 I)에서의 콘크리트는 자기수축만을 나타내었으며, W/C가 낮을수록 자기수축이 증가하였다. 처음 6일간 수중 양생한 후 $20{\pm}1^{\circ}C,\;60{\pm}3%$ RH의 조건에 노출시킨 기건 양생(조건 II)에서는 콘크리트가 팽창하였다가 수축하였다. 최대 팽창량은 $15{\sim}40{\pm}10^{-6}$ 정도였으며, W/C가 0.32인 콘크리트에서 가장 큰 전체 수축(자기수축+건조수축)량을 보였다. 처음부터 기건 양생(조건 III)한 콘크리트의 전체 수축은 양생 조건 II에서보다 증가하였다. 6일간의 밀봉 양생 후 기건 양생(조건 IV)한 경우에는 전체 수축이 양생 조건 III에 비해 다소 줄어들었다. 양생 조건 I, III, IV에서의 수축 결과로부터 순수한 건조수축량을 구할 수 있으며, 전체 수축량은 비슷함에도 불구하고 W/C가 증가함에 따라 건조수축이 증가하였다. 이는 W/C가 큰 콘크리트에서는 건조수축이 전체 수축을 지배함을 의미한다. 다시 말해, W/C가 낮은 콘크리트인 경우 전체 수축에서 자기수축이 차지하는 비율이 증가하기 때문에 잠재적인 균열 발생 측면에서 자기수축에 대한 검토가 반드시 요구된다. 결론적으로, 고강도 또는 고성능 콘크리트의 전체 수축은 적절한 초기 수중 양생을 통하여 효과적으로 줄일 수 있을 것으로 판단된다.