• 제목/요약/키워드: dry test

검색결과 1,848건 처리시간 0.035초

의류제품의 소비자 불만원인에 대한 연구 -사고 의류제품 원인규명 시험의뢰 사례를 중심으로- (A Study on the Causes of Consumer Complaints towards Apparel Products -Based on Laboratory Test Cases-)

  • 한은주;조성교
    • 한국의류학회지
    • /
    • 제37권7호
    • /
    • pp.864-873
    • /
    • 2013
  • This study analyzed the correlation between the sources of the complaints and various factors such as gender, garment type, fabric type, textile material and washing methods for products. This survey utilized a total of 2,609 consumer apparel product complaint cases filed with the Korea Consumer Agency between 1997 and 2009. In regards to consumer liability: it was found that more incidents of failures due to carelessness were reported among men's clothes, knitted garments, cotton clothes, polyester clothes, wool blend clothes, pants, shirts, sportswear, and laundry only clothes. In regards to dry cleaner's liability: women's goods, woven clothes, silk clothes, cotton blend clothes, jackets, shirts and hanbok, and dry clean only clothes indicated problems more frequently. In regards to manufacture's liability: women's clothes, woven clothes, wool clothes, silk clothes, wool blend clothes, polyester blend clothes, formal dress clothes, jackets, hanbok, and dry clean only clothes indicated problems more frequently. This study provides consumers with information necessary to take preventive measures and basic information that can be utilized to improve the quality of production and services by understanding the sources of dissatisfaction, type of clothes found with problems, and the main causes of consumer complaints for garment products according to who is liable.

Evaluation of Contaminant Concentrations in Wet and Dry Seasons during Pump-and-Treat Pilot Tests

  • Jeon, Woo-Hyun;Lee, Jin-Yong;Kwon, Hyung-Pyo;Jun, Seong-Chun;Cheon, Jeong-Yong
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권6호
    • /
    • pp.18-31
    • /
    • 2013
  • This study was performed to examine use of the pump-and-treat method for remediation of TCE, CF and CT in groundwater contaminated by DNAPL. The Woosan industrial complex is located in Wonju, about 120 km east of Seoul, Korea. Two pumping wells (KDPW7 and KDPW8) and five monitoring wells (KDMW7, KDMW8, KDMW9, KDMW10, and SKW2) were installed for the test. An asphalt laboratory is a main source of the extensive subsurface contamination at this site. To evaluate change in the concentrations of TCE, CF, and CT in groundwater in the study area, three rounds of pump-and-treat pilot tests were performed (6 July to 6 August, 22 August to 6 September, and 19 September to 2 December in 2011). The groundwater levels and the concentrations of TCE, CF, and CT exhibited negative correlations in the wet season but positive correlations in the dry season, which suggests that the TCE concentrations were mainly controlled by dilution through rainfall during the wet season and by residual TCE, CF, and CT in the unsaturated zone during the dry season. These possibilities should be considered in the full-scale remediation plan.

SUS630 소재의 UNSM(초음파 나노 표면 개질)처리 전후 Dry, Grease 윤활, Oil 윤활 상태하에서 마찰특성에 대한 실험적 연구 (SUS630 stainless steel friction characteristics in Dry, Grease and Oil-lubricated conditions before and after Ultrasonic Nano Crystal Surface Modification)

  • 최갑수;편영식;박정현;아마노브아외즈한;김준형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.519-520
    • /
    • 2010
  • PDF

바텀애시 경량골재 콘크리트 압축강도에 대한 기포 혼입률 및 양생온도의 영향 (Effect of Foam Volume ratio and Curing Temperature on Compressive Strength of Lightweight using Bottom Ash Aggregates)

  • 이광일;양근혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.168-169
    • /
    • 2019
  • This study examined the effect of foam volume ratio and curing temperature the air dry density and compressive strength of lightweight concrete using bottom ash. Test results showed that the lightweight concrete possessed the compressive strength of 3.4~22.7 MPa at the air dry density of 1,041~1,583 kg/m3.

  • PDF

건식변압기 수명예측에 관한 연구 (A Study on the lifetime Expectation of Dry type Transformer)

  • 김민규;이정기;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2106-2108
    • /
    • 2005
  • This paper describes a method of lifetime expectation for the dry-type molded transformer which is widely used in the domestic distribution system. And the result of the temperature accelerated aging test for the winding insulation and the analyzed report on the reliability are included in this study.

  • PDF

보강 혼합토의 역학적 특성(II) -섬유 혼합토- (Mechanical Characteristics of Reinforced Soil(II) -Fiber Reinforced Soil-)

  • 송창섭;임성윤
    • 한국환경복원기술학회지
    • /
    • 제5권6호
    • /
    • pp.37-42
    • /
    • 2002
  • This study has been performed to investigate the physical and mechanical characteristics of compaction, volume change and compressive strength for reinforced soil mixed with polypropylene fiber, and to confirm the reinforcing effects with admixture such as polypropylene fiber. To this end, a series of compaction test and compression test was conducted for clayey soil(CL) and polypropylene fiber reinforced soil. In order to determine proper moisture contents and mixing ratio, pilot test was carried out for natural soil and PFRS(polypropylene fiber reinforced soil). And the mixing ratio of mono-filament fiber and fibrillated polypropylene fiber admixture was 0.1%, 0.3%, 0.5% and 1.0% by the weight of dry soil. From the experimental results, it was found that the optimum moisture contents(OMC) increased with the mixing ratio of fiber, but the maximum dry unit weight and the volume change was decreased with the mixing ratio. It means that the improvement of the workability and the reduction of the weight of embankment was done by the addition of the polypropylene fiber. And, from the compression test results, it was found that the addition of the polypropylene fiber remarkably improved the compressive strength of PFRS. And it was observed in the viewpoint of strength that the fibrillated polypropylene fiber reinforced soil was more effective than the mono-filament polypropylene fiber reinforced soil.

Fe계 합금 분말 소결품(SMF9060)의 마모 특성 연구 (A Study on Tribological Characteristics of Powder Sintered Fe-base Alloy (SMF9060))

  • 김상윤;김대욱;박영민;신동철;김태규
    • 열처리공학회지
    • /
    • 제27권2호
    • /
    • pp.65-71
    • /
    • 2014
  • SMF9060 material is a Fe-based powder sintered alloy that is used for several automobile components such as Synchronize Hub, oil pump and transmission. These components are required excellent wear resistance and durability. In this study, we have performed a dry wear test at the ambient air and Ar gas conditions in the room temperature, and a lubricant wear test at the room temperature and engine oil temperature of $100^{\circ}C$. The amount of wear volume and coefficient friction are measured by a Profilometer and a Ball on disk type wear tester. The wear volume in Ar gas condition was a little higher than that in the ambient air condition. However the wear volume in the lubricant wear condition was much lower than in the dry wear condition. XRD analysis of the debris in Ar gas condition showed that the oxide film was not formed.

모형시험과 수치해석을 이용한 조적식 석축옹벽의 거동 특성 (Behavior of Dry-stone Segmental Retaining Wall Using Physical Modeling and Numerical Simulation)

  • 김성수;목영진;정영훈
    • 한국지반공학회논문집
    • /
    • 제27권9호
    • /
    • pp.25-36
    • /
    • 2011
  • 조적식 석축옹벽의 거동 특성을 규명하기 위하여 실내 모형시험과 수치해석을 수행하였다. 실내 모형시험에서 옹벽 블록과 뒤채움재의 변위를 측정하기 위해 PIV 기법의 디지털 이미지 해석을 실시하였다. 유한요소 수치해석을 위해 상용프로그램인 ABAQUS를 사용하였다. 모형시험에서 관찰된 뒤채움재의 변위 발생 과정은 파괴면의 형성이 점진적임을 보여준다. 수치해석 결과에서 석축옹벽의 시공 과정에서 발생하는 전체적인 수평 토압 분포는 기존의 Rankine 이론과 큰 차이가 없지만, 뒤채움재의 내부 마찰각과 석축을 구성하는 석재 간의 마찰각이 작으면 토압의 분포가 불규칙해짐을 확인하였다.

보일러용 STS 444재 용접부의 수소취성에 미치는습기의 영향 (Effect of Humidity on the Hydrogen Embrittlement of STS 444 Weld Zone for Boiler)

  • 임우조;최병일;윤병두
    • 수산해양교육연구
    • /
    • 제18권1호
    • /
    • pp.58-64
    • /
    • 2006
  • In order to examine the effect of humidity on hydrogen embrittlement of STS 444 weld zone for boiler with dry and wet welding conditions, this paper was carried out the accelerated hydrogen osmosis test and the electrochemical Tafel polarization test. In 0.5M $H_2SO_4$ + 0.01M $As_20_3$ solution, this test is added to load of $1400kg/cm^2$ together with hydrogen osmosis by current of $50 {mA/cm^2}$ for 60 min.. The electrochemical Tafel polarization test was carried out in 0.5M $H_2SO_4$ + 0.01M $As_20_3$ solution. Therefore, the effect of humidity on hydrogen embrittlement of STS 444 was considered. The main results are as following: On the basis of hydrogen embrittlement mechanism, that is, integrated electrochemical polarization characteristics with the established mechanism of hydrogen embrittlement, the reduction rate of corrosion current density of weld zone in the wet weld condition is larger than in the dry condition. We can nondestructively predict the degree of hydrogen embrittlement of STS 444 weld zone for boiler through the reduction rate of electrochemical corrosion current density.

$K_o$-재하/제하에 의한 건조모래의 거동(II): 다주기 시험 (Behaviour of Dry Sand under $K_o$-Loading / Unloading Conditions(II) : Hysteretic Test)

  • 정성교;정진교
    • 한국지반공학회지:지반
    • /
    • 제11권1호
    • /
    • pp.23-40
    • /
    • 1995
  • 다주기 Ko-재하/제하 시에 수평응력의 변화특성을 관찰하기 위하여 7종류의 시험모형을 선 정하였고, Ko조건을 크게 만족할 수 있도록 특별히 고안한압밀링 형태의 Ko-시험기를 제작하여 실내 건조된 모래에 대하여 실험을 수행하였다. 시험모형은 동일한 재하/제하 응력의 반복, 최대선행응력을 초과하는 반복 재하/제하, 그리고 최대선행 연직응력 내의 반복 재하/제하 Ko시험으로 구분된다. 실험결과에서 다주기 이력모형도 역시 기존의 단주기 이력모형을 확대하여 사용할 수 있음을 보였다. 여기서, 제하시의 지수 (a 및 a*)와 재재하 시의 계수(mr 및 mr*)는 응력이력의 형태, 반복회수 및 상대밀도에 따라 주로 지배되었다.

  • PDF