• 제목/요약/키워드: drop system

검색결과 1,909건 처리시간 0.028초

EHD 원리를 이용한 정전기장 유도 잉크젯 프린터 헤드의 마이크로 Drop-on-Demand 제팅 성능 연구

  • 최재용;김용재;손상욱;안기철;이석한;고한서;;변도영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1947-1950
    • /
    • 2008
  • Printing technology is a very useful method in the several process of industrial fabrication due to noncontact and fast pattern generation. To make micro pattern, we investigate the electrostatic induced inkjet printer head for micro droplet generation and drop-on-demand jetting. In order to achieve the drop-on-demand micro droplet ejection by the electrostatic induced inkjet printer head, the pulsed DC voltage is supplied. In order to find optimal pulse conditions, we tested jetting performance for various bias and pulse voltages for drop-on-demand ejection. In this result, we have successful drop-on-demand operation and micro patterning. Therefore, our novel electrostatic induced inkjet head printing system will be applied industrial area comparing conventional printing technology.

  • PDF

Flow Pattern and Pressure Drop of Pure Refrigerants and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권12호
    • /
    • pp.2289-2295
    • /
    • 2005
  • Two-Phase flow pattern and pressure drop data were obtained for pure refrigerants R134a and R123 and their mixtures as test fluids in a horizontal tube. The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section. The flow map of Baker developed for air-water two-phase flow at atmospheric pressure failed to predict the observed flow patterns at the higher value of the mass velocity used in the present study. The map of Kattan et al. predicted the data well over the entire region of mass velocity selected in the present study. The measured pressure drop increased with an increase in vapor quality and mass velocity. A new two-phase multiplier was developed from a dimensional analysis of the frictional pressure drop data measured in the present experiment. This new multiplier was found successfully to correlate the frictional pressure drop.

교류전위차법을 이용한 효과적인 응력확대계수의 측정 방법 (Effective Way of Measuring $K_I$ by Means of ACPD Technique)

  • 이정희
    • 비파괴검사학회지
    • /
    • 제19권1호
    • /
    • pp.8-15
    • /
    • 1999
  • 교류전위차법 (alternating current potential drop : ACPD)을 이용하여 이차원 표면균열을 갖고 있는 강자성체 (ferromagnetic material)와 상자성체 (paramagnetic material)의 모드 I (opening mode) 응력확대계수($K_I$)를 효과적으로 계측하는 방법을 개발하기 위하여 하중에 따른 교류전위차 변화(change in ACPD)에 미치는 자속(magnetic flux)의 영향을 연구하였다. 그리고 하중에 따른 전위차 변화에 미치는 탈자(demagnetization) 및 균열길이의 영향을 연구하였다. 기전력을 많이 유도할 수 있도록 설계된 계측계의 경우 하중에 따른 교류전위차 변화량은 크게 증가하였다. 아울러 교류전위차 변화와 응력확대계수 변화 사이의 관계는 탈자 등의 조치가 없어도 선형적이며, 탈자는 전위차 변화에 거의 영향을 미치지 않았다. 일정 $K_I$ 변화에 의한 전위차 변화량은 균열길이에 의존하지 않고 계측계에 의존한다. 교류전위차법을 이용하여 효과적으로 응력확대계수를 결정하는 방법은 기전력을 많이 유도할 수 있도륵 설계된 계측계를 사용하여 교류전위차 변화를 측정하는 것이다.

  • PDF

폐열 회수 시스템용 공랭식 응축기의 압력 손실 저감 설계 (A Design Process for Reduction of Pressure Drop of Air-cooled Condenser for Waste Heat Recovery System)

  • 배석정;허형석;박정상;이홍열;김찬중
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.81-91
    • /
    • 2013
  • A novel design process of a parallel multi-flow type air-cooled condenser of a dual-loop waste heat recovery system with Rankine steam cycles for improving the fuel efficiency of gasoline automobiles has been investigated focusing on reduction of the pressure drop inside the micro-tubes. The low temperature condenser plays a role to dissipate heat from the system by condensing the low temperature loop working fluid sufficiently. However, the refrigerant has low evaporation temperature enough to recover the waste from engine coolant of about $100^{\circ}C$ but has small saturation enthalpy so that excessive mass flow rate of the LT working fluid, e.g., over 150 g/s, causes enormously large pressure drop of the working fluid to maintain the heat dissipation performance of more than 20 kW. This paper has dealt with the scheme to design the low temperature condenser that has reduced pressure drop while ensuring the required thermal performance. The number of pass, the arrangement of the tubes of each pass, and the positions of the inlet and outlet ports on the header are most critical parameters affecting the flow uniformity through all the tubes of the condenser. For the purpose of the performance predictions and the parametric study for the LT condenser, we have developed a 1-dimensional user-friendly performance prediction program that calculates feasibly the phase change of the working fluid in the tubes. An example is presented through the proposed design process and compared with an experiment.

경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (II) (Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (II))

  • 김주락;창상훈;박현준;이영흠
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1984-1990
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

소형 직교류형 냉각탑의 성능 특성에 관한 연구 (Performance Characteristics of Small Sized Cross-flow Cooling Tower)

  • ;김은필;김재돌;전절호;문춘근;윤정인
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.93-98
    • /
    • 2005
  • The performance of cooling tower is dependent on the thermal performance of the packings. It's assessed by heat transfer rate and fan power. In this study, new packing was developed for application in compact type cross-flow cooling tower. The packing characteristic curve and the pressure drop curve were obtained by measuring packing characteristic values and pressure drops of small sized filler in comparison to existing mid-large sized filler. The heat transfer characteristics on small sized filler are about 66% higher than existing mid-large sized filler. The pressure drop characteristics on small sized filler are about two times of the pressure drop characteristics on existing mid-large sized filler.

  • PDF

선박용 소음기 성능 시험 및 평가 (Performance Test and Evaluation of Ship Exhaust Huffier)

  • 김봉기;김상렬;김현실;신민철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.158-163
    • /
    • 2008
  • Muffler design in the exhaust system is critical to provide for low noise in shipboard spaces. In an attempt to effectively design the low noise muffler, it is important to evaluate the performance of the muffler considering not only the noise, but also pressure drop as well. For this purpose, a test system of large exhaust muffler for ship propulsion systems was designed based on ISO 7235. The substitution test for determining both the insertion loss and pressure drop of mufflers was carried out. A ship exhaust muffler is considered as a test example and the insertion loss and pressure drop are obtained.

  • PDF

원통다관식 열교환기의 쉘측 압력 손실의 연구 (Investigation of Pressure drop on shell side of shell and tube heat exchanger)

  • 이용범;한성건;고재명
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.32-37
    • /
    • 2008
  • The present work aims to determine the overall pressure losses in the shell from the point of entry of the fluid to the outlet point of fluid of shell and tube heat exchanger. The main contribution of the present work is concerned with calculating the pressure drop in the interior section and window section. Shell-side flow velocity distributions have been evaluated. We assume that the shell-side fluid is turbulent. The calculation procedure is based upon the Delaware method. Evaluation of pressure drop on the shell side will be helpful for a designer or manufacturer of a heat exchanger.

  • PDF

낙하/충격해석을 통한 전자렌지의 내충격설계 (Design for Improving Impact Resistance of Microwave Oven Using Drop/Impact Analysis)

  • 김진곤;김정윤;김흥수
    • 동력기계공학회지
    • /
    • 제13권3호
    • /
    • pp.53-58
    • /
    • 2009
  • The importance of cost reduction has grown bigger to ensure the competetive power of products in the electric home appliances industry. Thus, it is necessary to assess the reliability due to drop-impact happenning in process of distribution of microwave ovens with the panel and cavity of thinner thickness for cost reduction. In the present study, the drop/impact simulation using the explicit code LS-DYNA3D has been carried out for improving the impact resistance of a microwave oven. This CAE-based design approach can be successfully applied to enhance the deteriorated dynamic behavior under the impact conditions of dropping height 70cm according to ISTA procedure 2A.

  • PDF