• 제목/요약/키워드: drive method

검색결과 2,380건 처리시간 0.033초

한국의 그린 비즈니스/IT 실태분석을 통한 추진전략 우선순위 도출에 관한 연구 (Development of Korean Green Business/IT Strategies Based on Priority Analysis)

  • 김재경;최주철;최일영
    • Asia pacific journal of information systems
    • /
    • 제20권3호
    • /
    • pp.191-204
    • /
    • 2010
  • Recently, the CO2 emission and energy consumption have become critical global issues to decide the future of nations. Especially, the spread of IT products and the increased use of internet and web applications result in the energy consumption and CO2 emission of IT industry though information technologies drive global economic growth. EU, the United States, Japan and other developed countries are using IT related environmental regulations such as WEEE(Waste Electrical and Electronic Equipment), RoHS(Restriction of the use of Certain Hazardous Substance), REACH(Registration, Evaluation, Authorization and Restriction of CHemicals) and EuP(Energy using Product), and have established systematic green business/IT strategies to enhance the competitiveness of IT industry. For example, the Japan government proposed the "Green IT initiative" for being compatible with economic growth and environmental protection. Not only energy saving technologies but energy saving systems have been developed for accomplishing sustainable development. Korea's CO2 emission and energy consumption continuously have grown at comparatively high rates. They are related to its industrial structure depending on high energy-consuming industries such as iron and steel Industry, automotive industry, shipbuilding industry, semiconductor industry, and so on. In particular, export proportion of IT manufacturing is quite high in Korea. For example, the global market share of the semiconductor such as DRAM was about 80% in 2008. Accordingly, Korea needs to establish a systematic strategy to respond to the global environmental regulations and to maintain competitiveness in the IT industry. However, green competitiveness of Korea ranked 11th among 15 major countries and R&D budget for green technology is not large enough to develop energy-saving technologies for infrastructure and value chain of low-carbon society though that grows at high rates. Moreover, there are no concrete action plans in Korea. This research aims to deduce the priorities of the Korean green business/IT strategies to use multi attribute weighted average method. We selected a panel of 19 experts who work at the green business related firms such as HP, IBM, Fujitsu and so on, and selected six assessment indices such as the urgency of the technology development, the technology gap between Korea and the developed countries, the effect of import substitution, the spillover effect of technology, the market growth, and the export potential of the package or stand-alone products by existing literature review. We submitted questionnaires at approximately weekly intervals to them for priorities of the green business/IT strategies. The strategies broadly classify as follows. The first strategy which consists of the green business/IT policy and standardization, process and performance management and IT industry and legislative alignment relates to government's role in the green economy. The second strategy relates to IT to support environment sustainability such as the travel and ways of working management, printer output and recycling, intelligent building, printer rationalization and collaboration and connectivity. The last strategy relates to green IT systems, services and usage such as the data center consolidation and energy management, hardware recycle decommission, server and storage virtualization, device power management, and service supplier management. All the questionnaires were assessed via a five-point Likert scale ranging from "very little" to "very large." Our findings show that the IT to support environment sustainability is prior to the other strategies. In detail, the green business /IT policy and standardization is the most important in the government's role. The strategies of intelligent building and the travel and ways of working management are prior to the others for supporting environment sustainability. Finally, the strategies for the data center consolidation and energy management and server and storage virtualization have the huge influence for green IT systems, services and usage This research results the following implications. The amount of energy consumption and CO2 emissions of IT equipment including electrical business equipment will need to be clearly indicated in order to manage the effect of green business/IT strategy. And it is necessary to develop tools that measure the performance of green business/IT by each step. Additionally, intelligent building could grow up in energy-saving, growth of low carbon and related industries together. It is necessary to expand the affect of virtualization though adjusting and controlling the relationship between the management teams.

설계 일관성 평가 모형의 고찰과 개선방안 연구 (Review and Improvement of Highway Design Consistency Evaluation Models)

  • 김상엽;최재성;양지은;김문겸
    • 한국도로학회논문집
    • /
    • 제8권4호
    • /
    • pp.63-74
    • /
    • 2006
  • 합리적인 도로 설계를 통해 운전자들의 기대를 만족시켜, 운전자들이 도로의 조건을 충분히 인지하여 주행하도록 하는 것은 매우 중요하다. 이러한 도로의 경우 우리는 흔히 선형의 일관성이 확보되어 운전자들이 안전하고 편안한 차량 주행을 할 수 있는 것이라고 말한다. 위에서 언급한 설계 일관성의 확보 유무를 평가하기 위해 국내 외에서 많은 연구가 이루어지고 있다. 본 연구에서는 기존의 국내 외 설계 일관성 평가 방법을 유형별로 구분하여 정리해 보고, 국내현실에 가장 적합하다고 판단되는 방법론을 응용하여, 일반국도의 과거 조사 자료를 바탕으로 현실적인 설계 일관성기법을 개발하고자 한다. 본 연구에서 개발한 모형은 곡선구간 상류부 100m지점의 속도($V_t$)를 변수로 포함하는 예측식으로 양방향 2차로는 $R{\leq}200m$인 경우와 R>200m인 경우로 나누어 예측식을 개발하였다. $R{\leq}200m$인 경우에는 곡선반경(R)과 $V_t$의 영향이 있고, R>200m인 구간에서는 기하구조의 영향보다는 곡선 상류부 100m지점의 속도($V_t$)가 영향이 있는 것으로 판단된다. 양방향 4차로의 경우도 R값을 400m라는 값에서 두 구간으로 구분하여 예측하였지만 양방향 2차로와는 달리 두 구간에서 모두 기하구조의 영향보다는 $V_t$의 영향이 더 큰 것으로 판단되었다. 향후 보다신뢰도가 높은 예측모형식 개발을 위해서는 더욱 정확하고 다양한 기하구조의 자료의 수집이 필요하다. 그리고 곡선 상류부 직선구간의 여러 지점의 속도를 수집하면 보다 신뢰도가 높은 예측 모형식 개발이 가능할 것이다.

  • PDF

모바일을 활용한 형성평가가 과학수업의 흥미성과 자기주도성에 미치는 영향 (The Effects of Formative Assessment Using Mobile Applications on Interest and Self-Directedness in Science Instruction)

  • 곽형석;신영준
    • 한국과학교육학회지
    • /
    • 제34권3호
    • /
    • pp.285-294
    • /
    • 2014
  • 본 연구는 과학과 교수-학습활동의 형성평가에 모바일기기를 활용하여 피드백을 하고, 그것이 교수-학습 활동 과정에서 나타나는 흥미성, 자기주도성에 미치는 영향을 알아보는 것에 목적을 두고 있다. 모바일기기를 활용한 형성평가는 문제의 제시와 더불어 즉시 집계가 가능한 기능을 가지고 있기 때문에 교수-학습 과정에 그 기능을 적용함으로써 나타나는 효과를 알아보기 위함이다. 연구대상으로는 인천광역시 H초등학교 6학년 학생을 실험집단(21명)과 비교집단(21명)으로 선정하였다. 각 연구 대상 학생들에게는 연구를 실시한다는 내용을 사전에 알리지 않고 수업을 진행하는 방법만 다른 정도로 인식하도록 하였다. 이 연구를 위해 실험집단에 활용한 방법은 구글드라이브의 통계기능을 이용해 형성평가 문항을 편집하여, QR코드로 제공한 후, 교수-학습 과정에 투입하여 실험집단 학생들에게 해결하도록 하였다. 답변한 내용을 구글드라이브의 프리젠테이션 기능을 활용하여 해당교수-학습 과정에서 학생들에게 그래프, 빈도수, 비율 등의 방법으로 제시한 후 정답 및 오답에 따라 교수자는 교수-학습 과정에서 피드백을 실시하였다. 반면에 비교집단은 동일한 형성평가 문항을 지면으로 제공하여 풀도록 하였다. 이 과정에서 비교집단의 학생들은 채점시간의 부족으로 해당수업시간에 피드백을 실시하지 못하고 다음 차시에 실시하게 되었다. 제공된 문제는 과학과 교사용지도서에 수록된 문항을 그대로 활용하였다. 총 11차시에 적용한 후 연구자가 참고하여 구안한 모바일-형성평가 준거표를 5점 척도로 제작하여 비교집단과 실험집단에 제공하였다. 그 결과 실험집단의 지도교사는 교수-학습 과정 중 형성평가 29문항을 진행하였고 그 중 정답확인 5회, 부연설명 24회의 피드백을 제공한 것으로 나타났다. 교수-학습 과정 중에서 학생들이 느끼는 흥미성에서도 실험집단이 비교 집단에 비해 흥미성의 정도가 높았다(p<0.01). 흥미가 높았던 주요인으로 "스마트폰을 가지고 수업하는 것이 즐거웠다."라고 실험집단의 다수(15명)가 응답하였다. 교수-학습 과정의 자기주도성에 대한 질문에서도 실험 집단은 비교 집단에 비해 집중, 교수학습 과정 반영, 학습자수업점검 등에 대해 긍정적인 반응을 보였다(p<0.01).

부울경 광역도시철도망 구축 필요성에 관한 연구 - 국도 7호선 중심으로 - (A Study on the Construction Demand for Network of Metro Railroad in Busan-Ulsan-Gyeongnam Area - In the place of National Road No.7 -)

  • 최양원
    • 대한토목학회논문집
    • /
    • 제31권6D호
    • /
    • pp.771-778
    • /
    • 2011
  • 근래 양산시와 부산시간의 활발한 이동량에 따라 최근 도시철도 1호선 양산선(노포~북정)의 예비타당성조사가 완료되어 타당성이 있는 것으로 결론되어 짐에 따라 도시철도 서비스가 취약한 웅상지역의 교통문제를 개선하고 광역도시간의 균형발전을 도모할 수 있도록 부울경을 연계하는 광역도시철도망 구축 필요성이 요구되고 있다. 또한 광역도시철도망 구축의 필요성을 강조하기 위해 대상지역 수단별 통행량과 해당지역 도로통행배정을 조사하였고, 노선대안별 수송수요를 예측하여 수단별 통행량과 통행배정 결과에 따라 개략적인 경제적 분석을 위해 설정된 노선대안별 건설비와 편익을 산정하였다. 본 과업의 3개의 대상 노선안 중 효율적인 노선으로 선정된 노선 1안의 건설에 필요한 총 사업비는 7,943.2억원으로 산출되었으며, 사업비중 순공사비가 가장 많은 비용을 차지하고 있으며 다음으로 예비비, 차량구입비, 부대비 순으로 나타났으며 단, 용지보상비는 계상되지 않았다. 특히 노선 1안은 건설시 경제성 분석결과 편익/비용비가(B/C)가 0.584, 순현재가치(NPV)가 -2,174.7억원, 내부수익율(IRR)이 0.604%로 분석되어 현 단계에서는 경제성이 다소 없는 것으로 나타났으나, 장기적으로 노선 3안인 월평~용당의 양산구간만을 건설시 편익/비용비가(B/C)가 0.737로 나타나고 있다. 따라서 도시철도 서비스가 취약한 웅상지역 주민의 편의를 도모하기 위해 부산 도시철도 기본계획 재정비시 기존 신정선을 연장하여 도시철도 관련 상위계획에 본 과업노선을 포함시켜 장래 노선 2안인 부산~양산~울산으로 이어지는 광역도시철도망 체계 구축이 반드시 필요할 것으로 판단되고 있다.

해석수준과 메시지 프레이밍에 따른 자율주행택시의 사용의도에 관한 연구 (A Study on the Construal Level and Intention of Autonomous Driving Taxi According to Message Framing)

  • 윤승정;김민용
    • 지능정보연구
    • /
    • 제24권3호
    • /
    • pp.135-155
    • /
    • 2018
  • 본 연구는 최근 4차산업 혁명의 산물로 대두되고 있는 자율주행차가 대중교통 수단인 택시로 이용될 때 해석수준과 메시지 프레이밍에 따른 사용 의도의 차이를 분석하는 것이다. 해석수준이란 가까운 미래에 발생한 일과 먼 미래에 발생할 일을 가정하여 어떤 제품이나 서비스를 해석하는 것이 다르다는 것을 말한다. 메시지 프레이밍이란 긍정 혹은 부정의 표현 또는 혜택, 손실의 양극단의 메시지를 구성한 것을 말한다. 즉, 기존연구에서는 이 두 개념에 따라 제품이나 서비스의 가치를 다르게 해석한다고 한다. 본 연구는 자율주행차가 택시로 출시될 때 두 개념을 적용할 경우 사용 의도의 차이를 보이는지 살펴보고자 한다. 결과를 요약하면 우선, 메시지 프레이밍 구성에서 자율주행 택시를 이용할 경우 혜택(Gain)과 왜(Why) 사용해야 하는지를 설명한 메시지 형식과 자율주행 택시를 이용하지 않았을 경우 손실(Loss)와 어떻게(How)를 강조한 메시지를 구성하여 비교해 보았다. 두 메시지 프레이밍은 차이를 보였으며(t= 3.063) 혜택(Gain)과 왜(Why)를 설명한 메시지 형태가 더 높은 사용 의도를 보였다. 또한, 해석수준에 따른 결과를 요약하면 다음과 같다. 혜택(Gain) 및 손실(Loss)에 대한 먼 미래와 가까운 미래에 발생할 것을 가정한 경우 사용 의도에 차이가 있었으며, 구체적으로 혜택(Gain)을 설명한 메시지와 먼 미래에 발생할 것을 가정한 경우가 사용 의도가 높았다. 요약하면 자율주행 택시의 사용 의도를 높이기 위해서는 긍정의 메시지(Gain)와 먼 미래에 일어날 수 있는 것을 가정하여 사람들에게 메시지를 전달해야 한다는 결론이다. 또한, 본 연구를 통하여 향후 신기술의 출현에 대한 사용 의도 연구 시 연구방법을 활용할 수 있을 것이다.

호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가 (Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy)

  • 이양훈;이제희;유숙현
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.135-144
    • /
    • 2010
  • 목 적: 호흡동조 방사선치료용 팬텀 제작을 통해 실시간움직임관리(RPM, Real-time Position Management)에 의한 치료시 호흡에 따른 방사선 조사선량의 적절성을 평가 하고자 한다. 대상 및 방법: 호흡동조 팬텀은 선형 액츄에이터(SCN6-050-50, Dyadic, Japan) 2개, 아크릴판, 지지대, 철판 등으로 팬텀위에 측정 대상을 위치시켜 구동 가능(상 하, 전 후)하도록 제작하였다. 4D CT를 촬영해 환자의 호흡을 분석하여 컴퓨터를 통해 팬텀의 위치와 속도를 제어하여 움직임을 재현하였다. 호흡동조 팬텀위에 2D-Array (PTW)와 4.5 cm의 팬텀(White water 4.5 cm)을 위치하여 21 EX 15 MV X선을 100 Mu, 조사야 $10{\times}10\;cm$의 open field와 2 cm 간격으로 10 cm까지 정방형으로 움직이는 Sliding MLC (DMLC)를 Gantry $0^{\circ}$, $90^{\circ}$에서 팬텀을 (1) 움직이지 않은 경우 (2) 움직인 경우 (3) RPM을 이용하여 동조한 경우(30%)로 나누어 조사하였다. 7.5 cm의 팬텀에 0.125 CC 이온화전리함(PTW)을 위치하여 위와 같은 조건으로 측정하였다. 결 과: 이온화전리함에 의한 중심선량 측정값은 Gantry $90^{\circ}$, $10{\times}10\;cm$ 조사야와 DMLC을 이용한 조사에서 동조시 0.3%이내, 비동조시 약 2%의 오차가 있었다. 2D-Array를 통한 분석시 Gamma index Method (3 mm, 3%)를 적용한 경우 Gantry $90^{\circ}$, $10{\times}10\;cm$ 조사야와 DMLC을 이용한 조사에서 동조시 오차이내, 비동조시 전체 조사야의 약 16% 오차를 보였다. 결 론: 호흡동조 방사선치료용 팬텀의 자체 제작으로 환자 움직임에 의한 치료계획과 방사선 측정으로 인하여 치료시 실제 조사되는 방사선량의 정량적 분석이 가능하였으며, IMRT 환자의 RPM을 이용한 호흡동조 치료시 적절한 평가가 가능하였다.

  • PDF

일반 성인들의 심폐소생술 자기효능감에 미치는 영향 요인 (Factors Affecting Self-efficacy of Cardiopulmonary Resuscitation(CPR) in Adults)

  • 전소연
    • 농촌의학ㆍ지역보건
    • /
    • 제44권3호
    • /
    • pp.124-137
    • /
    • 2019
  • 이 연구는 일반 성인들을 대상으로 심폐소생술 자기효능감에 미치는 영향 요인들을 포괄적으로 탐색함으로써 일반인의 심폐소생술 시행률을 향상시킬 뿐만 아니라 궁극적으로 급성 심정지 환자의 생존율을 향상시키기 위한 다양한 전략 개발에 필요한 근거 자료를 마련하고자 수행하였다. 연구 자료는 질병관리본부가 매년 수행하는 2016년 지역사회 건강조사의 원시자료를 이용하였고, 연구대상은 성인(만 19-64세) 총 164,165명, 조사방법은 가구방문 1:1 면접 조사, 조사기간은 2016년 8월 16일부터 10월 31일까지이었다. 조사내용은 심폐소생술 자기효능감 보유여부, 심폐소생술 용어 인지여부, 심폐소생술 교육 경험여부, 인구사회학적 특성, 의료 특성, 건강증진 행위, 안전 행위 실천여부를 파악하였다. 일반 성인들의 심폐소생술 자기효능감 보유율은 60.6%로 다소 낮은 수준이었다. 로지스틱 회귀분석 결과, 심폐소생술 자기효능감 영향 요인으로 고연령 일수록, 남자가, 읍면지역 거주자가, 고학력일수록, 직업이 있을 때와 특히 군인에서, 미혼보다는 배우자가 없을 때 심폐소생술 자기효능감이 있을 가능성이 높았다. 평생 심폐소생술 교육 경험이 있을 때, 최근 2년간 심폐소생술 교육 경험이 있을 때, 최근 2년간 마네킨을 이용한 실습 교육 경험이 있을 때 심폐소생술 자기효능감이 있을 가능성이 높았다. 1년간 사고나 중독으로 응급실 방문이 있을 때, 신체활동 실천을 할 때, 자전거 운전을 할 때, 다른 사람 운전차량 뒷좌석 탑승 시 안전벨트를 착용할 때, 버스 탑승 시 안전벨트 착용할 때에 심폐소생술 자기효능감이 있을 가능성이 높았다. 결론적으로 일반 성인들을 대상으로 심폐소생술 자기효능감의 향상을 도모하는 전략 수립 시 영향요인으로 밝혀진 최근 시기의 심폐소생술 교육 경험률 향상, 건강증진 행위 실천 향상, 안전 행위 실천을 향상 시킬 수 있는 교육 프로그램이나 전 국민 대상 홍보 전략 등이 마련되어야 하겠다. 일반 성인들의 심폐소생술 자기효능감 향상은 실제 목격자 심폐소생술 시행률을 높이며 궁극적으로는 심정지 환자의 생존율 향상에 기여할 수 있을 것이다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과 (The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV)

  • 임채만;장재원;최강현;이상도;고윤석;김우성;김동순;김원동;박평환;최종무
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권3호
    • /
    • pp.351-360
    • /
    • 1995
  • 연구배경: 압력보조는 환자의 흡기시 정해진 양의 양압을 보조하여 상시호흡량을 증가시키거나, 호흡일을 경감시키는 목적으로 쓰이는 기계환기법으로 본 연구는 자발적 호흡이 허용되는 SIMV 및 CPAP 양식에서 PS를 사용할 경우 환자의 호흡역학상 어떤 차이가 있는지 알아보고자 하였다. 방법: 중환자실에 입원하여 호흡부전으로 기계환기중인 환자로 임상적으로 안정되었고 자발적 호흡횟수가 분당 12회 이상인 환자 14명을 대상으로, 먼저 CPAP(3 cm $H_2O$) 양식하에서 0, 5, 10 및 15 cm $H_2O$의 PS를 순서대로 적용하면서 CP-100 pulmonary monitor(Bicore, USA)를 이용하여 호흡역학 지수들을 측정하고 이어서 SIMV 양식으로 바꾸어 같은 방법으로 호흡역학 지수들을 측정하였다. 결과: 1) CPAP 및 SIMV 방식하에서 PS가 호흡역학에 미친 공통된 효과 CPAP 양식하에서 PS를 증가시킴에 따라 상시호흡량은 증가하였고, WOB과 PTP는 감소하였다. SIMV 방식하에서도 PS를 증가시킴에 따라 상시호흡량은 증가하였고, WOB과 PTP 역시 유의하게 감소하였다. 2) CPAP 및 SIMV 방식하에서 PS가 호흡역학에 미치는 효과의 차이 CPAP 방식하에서 PS를 증가시킴에 따라 분당호흡수는 유의한 변동이 없었고, $P_{0.1}$$T_1/T_{TOT}$은 유의하게 감소되었다. SIMV 방식하에서 PS를 증가시킴에 따라 분당호흡수는 유의하게 감소한 반면, $P_{0.1}$$T_1/T_{TOT}$은 유의한 변동이 없었다. 3) CPAP+PS 양식에서 SIMV 단독양식에서와 같은 상시호흡량을 얻는 상태에서의 호흡역학의 비교 동일 환자에서 CPAP+PS 양식으로 SIMV 단독양식에서의 상시호흡량이 얻어지는 상태에서 분당호흡수 WOB, $P_{0.1}$ 등에는 양 방식 간에 차이가 없었으나 PTP와 $T_1/T_{TOT}$은 CPAP+PS 양식이 유의하게 낮았다. 결론: 기계호흡에서 압력보조의 사용은 CPAP 및 SIMV 양식 모두에서 상시호흡량을 증가시키고, 환자의 호흡일, 호흡근 산소소모량 지수를 감소시켰으며, 분당호흡수의 감소는 SIMV 방식에서만 관찰되었고, 중추성호흡추진력의 감소와 호흡근의 지구력지수의 호전은 CPAP 방식에서만 관찰되었다. 한편 상시호흡량이 같은 수준에서의 CPAP+ PS 방법은 SIMV 법에 비해 호흡근의 일효율이 더 높고 호흡근의 지구력지수가 더 우수하였다. 따라서, 기계적환기 유지기나 이탈과정의 환자에서 압력보조의 겸용은 환자의 호흡역학 상태를 개선하는 것으로 사료된다.

  • PDF