• Title/Summary/Keyword: drinking water supply

Search Result 251, Processing Time 0.025 seconds

A survey on the Sanitary Conditions of Water Supply and Privy Facilities to the Rural Area. (일부 농촌지역의 급수시설 및 분뇨처리에 대한 위생학적 조사)

  • 기윤호
    • Journal of Environmental Health Sciences
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 1977
  • The survey on the sanitary conditions to the water supply facilities, privy facilities and disposal methods of human excreta in Sindong area of Choonseung-gun, Kangwon Province was carried out during 7 months from May to November, 1976. The results of the survey are as follows. 1) The pump-wells are used in the 1,185 households as 66.7% of 1,775 and are almost private. 2) The materials of drainage floors and drainage are almost cement, and the drainages are good condition. 3) Most parts of dug-wells have been used beyond 9 years after installation, and disinfection of water has not been carried out in the case of 68.1% of total wells. 4) Objectives of water use to the number of households as 60.2% are drinking, kitchen and cleaning. 5) Water consumption per capita day is estimated to be about 22.7% litters. 6) 1,521 households as 85.7% of total 1,775 possess their private privies and the numbers as 80.6% of the private privies are located outside the houses. 7) The privies are needed to be improved much more in the view point of excreting to the ashpile instead of the septic tank in the case of 39.2% of total households. 8) Human excreta as manure are used to the field in the number of households as 82.4 of total 1,316.

  • PDF

Epidemiological Analysis of a Food Poisoning Outbreak Caused by Multiple Pathogens in a High School in Chungnam Korea, 2019 (2019년 충남지역 고등학교에서 발생한 다병원체에 의한 집단식중독의 역학적 분석)

  • Lee, Hyunah;Choi, Jihye;Park, Seongmin;Nam, Hae-Sung;Choi, Jinha;Park, Junhyuk
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.5
    • /
    • pp.434-442
    • /
    • 2019
  • Objectives: This study was performed in order to report the epidemiological features of a food poisoning outbreak caused by multiple pathogens in a high school in Chungcheongnam-do Province, Korea in April 2019 and to suggest measures to prevent a similar incidence. Methods: A total of 39 patients with diarrhea were examined. Environmental samples were obtained from 6 food handlers, 4 food utensils, 72 preserved foods served during the food poisoning outbreak, 9 door handles, 10 drinking water samples from water dispensers, and 6 ground water samples from water taps. These analyzed to detect viruses and bacteria. Results: Among the 39 patients, 21 cases (53.8%) of enteroaggregative E. coli (EAEC), 7 cases of Staphylococcus aureus (17.9%), and 17 cases of norovirus (43.6%) were positive, and in 16 of the cases a co-infection with at least one other pathogen were observed. EAEC was assumed to be transmitted from contaminated drinking water because it was also detected in the water sample from a water dispenser in the dormitory. Staphylococcus aureus was isolated only in the fecal samples of patients, meaning it was not possible to trace its origin. The genotype of norovirus detected in the drinking water and ground water was consistent with that isolated from patients, and it was determined that the norovirus infection originated from the school's water environment. Conclusions: These findings indicate that a lack of environmental hygiene management related to school meals caused the food poisoning incident. In particular, a lack of management of drinking water, water supply, and personal hygiene should be pointed out. This should be urgently addressed and continuous monitoring should be carried out in the future. In addition, students and staff should be educated and trained to improve their personal hygiene.

Impact of Salt Intake on Red and Fallow Deer Production in Australia - Review -

  • Ru, Y.J.;Glatz, P.C.;Miao, Z.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.12
    • /
    • pp.1779-1787
    • /
    • 2000
  • Southern and south-western Australia is a typical mediterranean environment, characterised by wet, cold winters and dry, hot summers. The evaporation rate varies significantly in summer, resulting in a high salinity of drinking water for grazing animals. In addition, a large amount of land in the cropping areas is affected by salt. Puccinellia, tall wheat grass and saltbushes have been planted to improve the soil condition and to supply feed for grazing animals. Animals grazing these areas often ingest an excessive amount of salt from soil, forage and drinking water which can reduce feed intake, increase the water requirement, depress growth and affect body composition as demonstrated in sheep. While the deer industry has been successfully developed in these regions, the potential impact of excessive salt intake on deer production is unknown. The salt tolerance has been well defined for sheep, cattle and other livestock species, but the variation between animal species, breeds within species, maturity status and grazing environments makes it impossible to apply these values directly to deer. To optimise deer production and effectively use natural resources, it is essential to understand the salt status of grazing deer and the impact of excessive salt intake on growth and reproduction of deer.

Recent Progress of Membrane Technology and its New Application for Water Treatment

  • Hiroyuki, Yamamura;Yoshinari, Fusaoka;Masaru, Kurihara
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.81-94
    • /
    • 1998
  • Nowadays, membrane separation such as reverse osmosis (RO) and ultrafiltration (UF) play an important role in the industrial separation technology. Among desalination technologies available today, reverse osmosis is usually the most economical process for wide range of water salinity. Main applications include production of high purity water, desalination of seawater and brackish water for a drinking water supply, treatment of waste water for environmental protection, and recovery of precious materials from industrial waste water. In this paper, we will mention membrane performance and these practical use focused on reverse osmosis membranes and ultrafiltration membranes recently developed by Toray.

  • PDF

Improvement Manual for Waterworks Facilities to Reduce the Damage of Volcanic Ash (화산재 피해 저감을 위한 상수도시설 대응매뉴얼 개선방안)

  • Yoon, Hyoung-Uk;La, Da-Hye;Lee, Gyeng-Bin;Kim, Min Gyu;Chung, Il-Moon
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.267-276
    • /
    • 2018
  • Volcanic ash from volcanic eruptions spreads to vast areas hundreds of kilometers away, and when volcanic ash flows into surface waters, it will be damaged by water supply. In case of water supply facilities, it provides to people drinking water and domestic water, be consumed by the people cause social disorder when water supply is cut off due to damage such as water pollution caused by harmful materials of volcanic ash. However, when we looked at the disaster management manual, the establishment of a water supply facility manual to deal with the damage of volcanic ash was found to be insufficient. Therefore, in this study, the existing volcanic and water pollution related manuals were analyzed and problems were derived. In order to make quick situation judgment and response activities, we have suggested the scope of the water supply facility manual, disaster type, major missions and system of related organizations, and scenario of crisis situation by disaster type.

Investigating the Causes and Control Measures for Precipitated Suspended Solids in the Underground Reservoir Tank in an Apartment (공동주택 지하저수조 내 침전된 부유성 고형물의 발생원인 및 제어방안)

  • JunYoung Jang;JooWon Kim;KiPal Kim;HyunSang Shin;ByungRan Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.2
    • /
    • pp.153-161
    • /
    • 2023
  • The reservoir tank in an apartment is crucial for maintaining the quality of drinking water after it has undergone treatment. Investigating the water quality and potential contaminants in the reservoir tank is essential to ensure the safety of the drinking water. This study examined the water quality and precipitated suspended solids that accumulate at the bottom of the reservoir tanks in four apartments located in Gyeonggi province. As a result of the water quality investigation, turbidity increased proportionally to the distance from the water treatment plant (WTP) to the household. Heavy metals were also detected in the reservoir tank inlet but not in the water supplied from the WTP. The precipitated suspended solids (SS) in the reservoir tank contain high levels of heavy metals and total organic carbon (TOC). The precipitated SS mainly consists of Al, Mn, and Fe, which are expected to be a combination with turbidity-inducing substances. The X-ray diffraction (XRD) analysis revealed the presence of γ-FeO(OH), MnO2, and β-Fe2O3 in the SS. Additionally, F-EEM analysis indicates that the dissolved organic matter in the SS is mainly derived from a natural water source and microorganism activities, including metal-oxidizing bacteria and biofilms that can absorb metal ions. Based on these findings, several countermeasures can be taken to prevent the inflow of SS into the household, including regularly cleaning the reservoir tank, replacing or cleaning old pipes in the water supply system, and implementing monitoring and filtering systems to manage the SS.

A Survey of Cryptosporidium Oocysts in Water Supplies during a 10-Year Period (2000-2009) in Seoul

  • Lee, Mok-Young;Cho, Eun-Joo;Lee, Jin-Hyo;Han, Sun-Hee;Park, Yong-Sang
    • Parasites, Hosts and Diseases
    • /
    • v.48 no.3
    • /
    • pp.219-224
    • /
    • 2010
  • This study has been conducted to estimate the occurrence of Cryptosporidium oocysts in water supplies in the Metropolitan area of Seoul, South Korea, for 10 years from 2000 to 2009. Water samples were collected quarterly at 6 intakes in the Han River and its largest stream and 6 conventional Water Treatment Plants (WTPs) serving drinking water for 10 million people of Seoul. Cryptosporidium oocysts were found in 22.5% of intake water samples and arithmetic mean was 0.65 oocysts/10 L (range 0-22 oocysts/10 L). Although the annual mean of oocyst number was as low as 0.04-1.90 oocysts/10 L, 3 peaks in 2004 and 2007 were observed and the pollution level was a little higher in winter. The lowest density was observed at Paldang intake and the pollution level increased at Kuui and Jayang intakes. At the end of the largest stream, oocysts were found in 70% of collected samples (mean 5.71 oocysts/10 L) and it seemed that its joining the Han River resulted in the increase at Kuui intake and downstream. Oocyst removal by physical process exceeded 2.0-2.3 log and then all finished water samples collected at 6 WTPs were negative for Cryptosporidium in each 100 L sample for 10 years. These results suggested that domestic wastewater from the urban region could be a source of Cryptosporidium pollution and separating sewage systems adjacent to the intakes could be meaningful for some intakes having weakness related to parasitological water quality.

Development of Stand-Alone Underground Water Pumping System using Photovoltaics System (태양광발전을 이용한 독립형 지하수 양수 시스템 개발)

  • Lee, Seung-Hun;Hwang, Jung-Hoon;Cho, Woon-Sik;Kim, Man-Il;Lee, Joon-Gee;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF

Water Quality Monitoring and Risk Assessment for Groundwater at Hoengseong, Gangwon-do Province (강원도 횡성지역의 지하수 수질 모니터링 및 인체 위해성 평가)

  • Gang, Seung-Hye;Kim, Ki-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.356-365
    • /
    • 2021
  • Background: Concerns have been raised regarding the criteria of groundwater, in particular in Gwangwon-do Province where many residents drink groundwater due to the poor supply of tap water and a high nonconformity rate with water quality criteria nationwide. Objectives: Water quality monitoring and risk assessment were conducted for groundwater in Hoengseong, Gangwon-do Province. Methods: A total of 46 items required for meeting drinking water criteria were analyzed from 258 samples collected from March 2017 through August 2018 (152 sites in 2017 and 106 sites in 2018). Risk assessment was conducted for two non-carcinogens (F- and NO3-N), and one carcinogen (i.e., arsenic) based on their high nonconformity to water quality criteria. Results: Water quality analysis revealed that the total proportion of nonconformities was determined to be 27.9%. The nonconformity rate for each content item is as follows: total colony counts (1.6%), total coliform (6.2%), Escherichia coli (1.2%), F- (8.1%), arsenic (4.7%), NO3-N (8.1%), pH (1.2%), manganese (0.4%), and turbidity (5.8%). Risk assessment indicated that fluoride induced a hazard quotient greater than 1 with the 95% UCL (Upper Confidence Limit) concentration of the total 258 sites and average, median, and 95% UCL concentrations of nonconformity sites. For NO3-N, there was no human health risk. For arsenic, the excess cancer risk exceeded the acceptable cancer risk of 1×10-6 with the average and 95% UCL concentrations of total 258 sites and average, median, and 95% UCL concentrations of nonconformity sites. Conclusions: This study suggests that it is necessary to expand water quality monitoring of groundwater and conduct a more detailed risk assessment in order to establish a health care plan for the residents of Hoengseong, Gangwon-do Province.

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.