• Title/Summary/Keyword: drinking water standard

Search Result 250, Processing Time 0.02 seconds

Groundwater Contamination by Cation, Anion and Pesticides (지하수중 음이온, 양이온, 및 금속의 함량)

  • 김형석;정세영;최중명
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.111-128
    • /
    • 1992
  • According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

  • PDF

농촌지역 간이상수도 수질에 대한 수리지화학적 특성: 충남 금산군 일대

  • 이진수;고경석;김용재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.369-372
    • /
    • 2004
  • This study presents the hydrogeochmical investigation to know the effect of geology and sources for water quality in small potable water supply system at rural area. The results of water quality in Geumsan area showed the 3.2% of water samples exceeded the limit of drinking water standard by bacteria. The hydrochemical investigation results indicated the high EC, Ca and HCO$_3$ in surface water and metasedimentary rocks and this is caused by the dissolution of calc-slicate minerals of metasedimentary rocks.

  • PDF

A Study on the Management & Utilization of School Drinking Water (학교음용수 관리 및 이용실태)

  • Hong, Jung-Ha;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.87-104
    • /
    • 2000
  • The purpose of this study was to obtain the basic data as a improvement method through the fact-revealing concerning the drinking water management of school and utilization of student. The problems of the research are as follows: First, to investigate status of management of drinking water by area and school. Second, to investigate student's utilization of drinking water by area and school. 1,400 students was selected at 45 elementary and middle-high schools located in Kang-won province, and this study was constituted of two questionnaires(for school's questionnaire and student's questionnaire). The results was analyse through the frequency analysis, $x^2$-test on the basis of the above research problem by SPSS program. The findings of this research are as follows; 1) The Management of School Drinking Water First, the source of school drinking water was mostly piped water. Inspection of water quality has been fulfilled under four times a year, in the other hands, from the result inspection, the schools which was given inadequate determination was 22.2%. Second, reservoir cleaning and hygiene inspection failed far short of the regulations. Especially, reservoir cleaning was managed by exterior consignment industry not low-level officials. Third, school water drinking was the most supplied through the type of water purifier. Water purifier has been distributed to city-located and middle-high school highly, factually the water from water purifier was served with water cup. Fourth, the selection standard of water drinking manager showed slightly differently by school, accordingly there need to develope integrated system with the respective to its effective systematic management. Fifth, water cup was mostly treated by only water clear, which is to vindicate the problems concerning hygiene management. 2) Utilization of school student on Drinking Water First, Disbelief on drinking water of school student was very high. Especially, proportion of middle-high school student's disbelief of drinking water was higher than elementary school student, also girls higher than boys. Many of student have heard to don't drink water from around people. And there were showed meaningful differences by area and school. Second, It was showed many student recognize had to utilize water purifier, boiled water. However, they have still drunken the tap water or portable water from their home. Third, Many of student showed negative response with the respective to the management conditions of drinking water in classroom, There were showed meaningful differences by area and school. From the fact-revealing of water cup management, Students mostly answered to 'only water clear' and the answer of 'None use' or 'With personal cup' was higher. Fourth, In bad experience of Drinking Water, student mostly answered to 'occasionally' and there were showed meaningful differences by school. student's disease experience with school drinking water was few and there were showed meaningful differences by area and gender.

  • PDF

Uranium in Drinking Water of Kyungpook Area in Korea (경북지역의 먹는 물에서 우라늄 검출 특성)

  • Lee, Hea-Geun;Cha, Sang-Deok;Kim, JeongJin;Kim, Young-Hun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.235-242
    • /
    • 2014
  • Uranium can be released into the water environment from natural sources and human activities. The natural source of uranium is dominant in the Korean soil and groundwater environments. Uranium has both of radioactive and chemical toxic properties. Therefore, a drinking water contaminated with uranium has a high health risk. This study was conducted to determine the uranium concentration of water systems including small village drinking water system, groundwater for drinking water purpose, spring water, groundwater monitoring well, and emergency water suppling system. The uranium concentration was compared with domestic and other countries' standard. The contamination level was also evaluated on the basis of geological characteristics of the area. Among total 803 samples, 6 exceeded the Korean standard, $30{\mu}g/{\ell}$ and this was about 0.7% of the total sample. On the basis of geology, uranium concentration appeared to be increased in order of biotite granodiorite > biotite granite > gneissoid granite. The highest level of uranium was 12.4 in average.

A Study On The Water Quality in Rural Area in Chuncheon-si (춘천시 일부 농촌 지역의 음용수 수질에 관한 조사연구)

  • Park, Sujung;Kim, Moon Kyung;Ki, Young Sun;Oh, So Rin;Shin, Mi-yeon;Oh, Ji Yoon;Byeon, Jae Cheol;Lee, Seong Min;Jung, Eun Hee;Kim, Eun Mi;Zoh, Kyung-Duk;Choi, Kyungho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.431-436
    • /
    • 2006
  • This study was conducted in the summer of 2005 in Shindong-myeon, Chuncheon-si, Gangwon-do to assess the quality of drinking water and to evaluate their potential pollutants. Ninety four water samples were collected from three classes of water supplies such as simple piped water, supplied own water and others (Supplied local water). Most residents used simple piped water (72.63%). 31.25% residents thought the water quality was bad and landfill was the main source of pollution that affected water quality. To correspond this perception, water quality was measured according to Drinking Water Quality Standard. The general bacteria, coliforms, and $NO_3-N$ exceeded the standard but the water qualities in these four areas were suitable for Drinking Water Quality Standard. The simple piped water showed low mean concentration of excess rate compared to supplied own piped water except general bacteria. Hardness, pH, and $NO_3-N$ showed significantly higher effects on drinking water quality. To evaluate the effect of effluent from landfill, water quality was measured according to distance and altitude. However, there was no effect of landfill effluent. To find out the effect of rainfall, we compared water quality of the year 2003 with that of 2005. The result showed significant differences in hardness and $NO_3-N$ concentration. This study confirmed that $NO_3-N$, coliforms, and general bacteria are main pollutant of water supply in rural community. Therefore, it is necessary to regularly maintain simple piped water supply, supplement sewer facilities, and educate residents about public health risk associated with drinking water in rural area.

Hygienic Quality of Drinking Water Served in Restaurants and Quality Characteristics of Drinking Water Boiled with Various Plant Materials (외식업소 음용수의 위생실태와 침출재료에 따른 기호성과 저장성)

  • Ahan, Yu-Bok;Jeong, Eun-Ju;Lee, Shin-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.3
    • /
    • pp.159-164
    • /
    • 2007
  • The viable cell of 60% drinking water among 25 drinking water served in restaurant of Daegu district showed above 100 CFU/mL which is sanitary standard of drinking water. The 50 CEO of restaurant considered drinking water served in their own restaurant as just safe and were very deficient in aware of sanitation about drinking water. Sensory quality of drinking water boiled with plant materials, such as barley, Cassia semen, corn, Buckwheat, Korean solomon's seal, Chamomile, Brown rice-green and peppermint was improved in color, taste, flavor and overall acceptability compare to marketed drinking water, respectively. Especially drinking water boiled with Korean solomon's seal was the best In overall acceptability. The number of total bacteria reached above $10^2 CFU/mL$ in marketed drinking water after 4 days storage at 10. But the growth of microorganism did not occur in boiled drinking water with Brown rice-green tea, Korean solomon's seal, barley, Cassia semen and com during storage for 10 days at $10^{\circ}C$, respectively. The number of total bacteria reached above $10^2 CFU/mL$ in marketed drinking water after storage for 1 days at $25^{\circ}C$. The growth of microorganism was accelerated in boiled drinking water with corn, Korean solomon's seal, barley, Cassia semen except Brown rice-green tea during storage far 10 days at $25^{\circ}C$, respectively.

Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju (광주지역 바닥분수의 수질특성 평가)

  • Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

Abundances of Uranium and Radon in Groundwater of Taejeon Area (대전지역 지하수에 함유된 우라늄 및 라돈의 함량)

  • Han, Jeong-Hee;Park, Kye-Hun
    • Economic and Environmental Geology
    • /
    • v.29 no.5
    • /
    • pp.589-595
    • /
    • 1996
  • The concentration of radioactive elements was measured from the groundwater samples of Taejeon Area. U and Rn concentrations of very high level were detected from many places, especially around Yusung. These levels are much higher than the concentration standards for the drinking water proposed by the United States Environmental Protection Agency. However, in Korea, there are no standard levels for the radioactive elements in drinking water yet. We think that it is necessary to provide such standards as soon as possible, and that the determination of radioactive elements in groundwater should be included in the routine analysis items for the drinking water quality, because many people currently use such relatively high level radioactive groundwater as their drinking water, especially around Yusung area.

  • PDF

Development of Online Tritium Radiation Continuous Monitoring Measurement System and Analysis Optimization Techniques (온라인 삼중수소 방사능 연속모니터링 측정시스템 개발 및 분석 최적화 기법 개발)

  • Hongyeon Lee;Junghun Kim;Raehyun Lee;Yeongtae An;Byeongu Kim;Minjae Choi;Bogil Kim;Yongju Shin
    • Journal of Radiation Industry
    • /
    • v.18 no.3
    • /
    • pp.155-166
    • /
    • 2024
  • In this study, a liquid scintillation spectrometer was developed for online continuous monitoring of tritium nuclides in water. The device consists of two photoelectron multiplier tubes (PMT), a simultaneous counting circuit, and a signal processing unit including a multi-channel analyzer (MCA). As a method to verify the performance of the equipment developed in this study, samples were prepared using a standard source, and the spectrum of tritium was measured to evaluate the detector characteristics such as efficiency, background (BKG), and minimum detectable activity (MDA). To evaluate the effect of pretreatment on tritium radioactivity measurement results, the MDA of water (seawater and groundwater) samples before and after pretreatment was calculated and compared. The results of the evaluation confirmed the satisfaction of the reference values of the Nuclear Safety Commission's "Discharge Control Standard in Drainage Water" and the World Health Organization's (WHO) "Tritium Radioactivity Concentration for Drinking Water Standards". The liquid scintillation spectrometer developed in this study, with or without pretreatment, confirmed detection performance equivalent to 1/100th of the discharge control standard for drainage water (40,000 Bq L-1) and the WHO's drinking water standard for tritium radioactivity (10,000 Bq L-1).

Sanitory Significance on Drinking Water Quality Standard (음체수 수질기준에 대한 위생학적 의의)

  • 김종택
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.58-62
    • /
    • 1994
  • Until 1960 water pollution was caused by virus but now in according to industrial develop cent it has been continued environmental pollution by surfactant heavy metal, and hazardous chemical substance erst.. It is possible to Prevent contamination by virus owing to development of antibiotic but not to dissolve basely health effect by hazardous chemical substances because it takes very long time, about 5-40 years, average 20 years, in appearing a disease after exposure by then To maintain human life for 75 years, it need 55 ton of water. In the experiment of Public Health Institute, Tokyo, they reported that over 200 chemical substances can be detected in case of human being to drink tap water of Tokyo(1989) continuously. In our country, elevation of life style and development of industry result in increase of water use and overappreciation of pesticides in farm land a(sects drinking water quality. We estimated analytical item of drinking water hygienically by dividing into 5 groups such as physical effect item health hazardous inorganic item and health hazardous organic item ect. based on hygienic purpose.

  • PDF