• Title/Summary/Keyword: drag coefficients

검색결과 313건 처리시간 0.026초

벽 근접 효과에 의한 물체의 항력 양력 변화 (EFFECT OF WALL PROXIMITY ON DRAG AND LIFT FORCES ON A CIRCULAR CYLINDER)

  • 박현욱;이창훈;최정일
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.68-74
    • /
    • 2012
  • Near-wall effect on wakes behind particles is one of the important factors in precise tracking of particles in turbulent flows. However, most aerodynamic force models for particles did not fully consider the wall effect. In the present study, we focused on changes of hydrodynamic forces acting on a particle depending on wall proximity. To this end, we developed an immersed boundary method with multi-direct forcing incorporated to a fully implicit decoupling procedure for incompressible flows. We validate the present immersed boundary method through two-dimensional simulations of flow over a circular cylinder. Comprehensive parametric studies on the effect of the wall proximity on the drag and lift forces acting on an immersed circular cylinder in a channel flow are performed in order to investigate general flow patterns behind the circular cylinder for a wide range of Reynolds number (0.01 ${\leq}$ Re ${\leq}$ 200). As the cylinder is closer to the wall, the drag coefficient decreases while the lift coefficient increases with a local maximum. Maximum drag and lift coefficients for different wall proximities decrease with increment of Reynolds number. Normalized drag and lift coefficients by their maximum values show universal correlations between the coefficients and wall proximity in a low Reynolds number regime (Re ${\leq}$ 1).

전산 유체 역학을 이용한 선박 방향타 주변의 항력 및 양력 계수에 대한 수치 시뮬레이션 (Numerical Simulation on Drag and Lift Coefficient around Ship Rudder using Computational Fluid Dynamics)

  • 구본국
    • 융합신호처리학회논문지
    • /
    • 제24권2호
    • /
    • pp.97-102
    • /
    • 2023
  • 방향타는 조선 분야에서 중요한 역할을 하기 때문에 방향타의 유체역학적 특성을 조사하기 위해 수치 시뮬레이션이 수행되었다. 유체역학적 힘과 같은 일부 값은 예인 탱크에서 쉽게 측정할 수 있지만, 실험을 통해 압력 분포, 속도 분포, 와류 발생과 같은 유동장에 대한 자세한 정보를 얻기는 어렵다. 본 연구에서는 전산유체역학(CFD)을 이용하여 방향타에 작용하는 유체역학 계수와 레이놀즈수가 미치는 영향을 연구하였다. 상용 전산유체역학 프로그램 Ansys Fluent를 이용하여 방향타 주위의 유동 특성을 연구하였고, 이때 k-epsilon 난류 모델이 사용되었다. 먼저 CFD 상용코드를 이용하여 KCS 방향타의 받음각에 따른 항력계수와 양력계수를 구하였다. 둘째, 동일한 조건에서 2차원 양력계수와 항력계수를 3차원 계수와 비교되었다. 셋째, 레이놀즈수가 유체역학적 힘에 미치는 영향이 연구되었다.

에어댐의 높이가 차체 표면의 압력변화에 미치는 영향 (Effect of the Heights of Air Dam on the Pressure Distribution of the Vehicle Surface)

  • 박종수;김성준
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.27-34
    • /
    • 2002
  • 3-D numerical studies are performed to investigate the effect of the air dam height and approaching air velocities on the pressure distribution of notchback road vehicle. For this purpose, the models of test vehicle with four different air dam heights are introduced and PHOENICS, a commercial CFD code, is used to simulate the flow phenomena and to estimate the values of pressure coefficients along the surface of vehicle. The standard $k-{\varepsilon}$ model is adopted for the simulation of turbulence. The numerical results show that the height variation of air dam makes almost no influence on the distribution of the value of pressure coefficient along upper and rear surface but makes strong effects on the bottom surface. That is, the value of pressure coefficient becomes smaller as the height is increased along the bottom surface. Approaching air velocity makes no differences on pressure coefficients. Through the analysis of pressure coefficient on the vehicle surface, one tries to assess aerodynamic drag and lift of vehicle. The pressure distribution on the bottom surface affects more on lift than the pressure distribution on the upper surface of the vehicle does. The increase of air dam height makes positive effects on the lift decrease but no effects on drag reduction.

  • PDF

자동차 공력저항 예측 프로그램 개발 및 형상인자의 최적화 (Development of a Predicting Program of Vehicle Aerodynamic Drag and Optimization of Shape Parameters)

  • 한석영;맹주성;김무상;박재용
    • 한국자동차공학회논문집
    • /
    • 제10권5호
    • /
    • pp.223-227
    • /
    • 2002
  • Wind tunnel test or CFD is used for predicting aerodynamic drag coefficient in domestic motor companies. But, wind tunnel test requires much cost and time, and CFD has a relatively large error. In this study a predicting program of the aerodynamic drag coefficient based on empirical techniques was developed. Also GRG method was added to the program in order to decide optimal values of some parameters. The program was applied to 24 cars and the aerodynamic drag coefficients were predicted with 4.82% average error. Optimization was also accomplished to 6 cars. Some parameters to be modified were determined (1) to reduce the afterbody drag coefficient to the value established by a designer and (2) to preserve the same drag coefficient as the original automotive when some parameters have to be changed in the viewpoint of design. It was verified that the developed program can predict the aerodynamic drag coefficient appropriately and determine optimal values of some parameters.

천음속 에어포일 유동에서 비평형 응축이 Force Coefficients 에 미치는 영향 (Effect of Non-Equilibrium Condensation on Force Coefficients in Transonic Airfoil Flow)

  • 전흥균;최승민;강희보;권영두;권순범
    • 대한기계학회논문집B
    • /
    • 제38권12호
    • /
    • pp.1009-1015
    • /
    • 2014
  • 본 연구는 NACA0012 천음속 에어포일 유동에 있어서 비평형 응축이 Force 계수(압력, 양력 및 항력계수)에 미치는 영향을 TVD 수치해석을 통하여 연구하였다. 정체점 온도 298 K, 받음각 ${\alpha}=3^{\circ}$인 경우, 주류 마하수 0.78~0.81에서는 정체점 상대습도의 증가함에 따라 양력은 단순 감소한다. 반면 Lift force break 마하수 영역의 주류 마하수에서는 정체점 상대습도의 증가에 따라 양력은 오히려 증가한다. 받음 각 ${\alpha}=3^{\circ}$, 정체점 상대습도가 0%인 경우, 주류 마하수의 증가에 따라 항력은 급격하게 증가하지만, 응축의 영향이 큰 60%인 경우에는 주류 마하수의 증가에 조금 증가할 뿐이다. 동일한 주류 마하수인 경우 비평형 응축에 따른 전 항력의 감소는 받음각과 정체점 상대습도가 증가할수록 크게 된다. 응축이 없는 ${\Phi}_0=0%$인 경우는 주류 마하수가 크고 받음각이 클수록 Wave drag은 크게 되나 응축의 영향이 비교적 큰 ${\Phi}_0=50%$ 이상인 경우는 오히려 Wave drag이 작아지는 것으로 나타났다. 한편, 정체점 상대습도가 낮고, 주류 마하수가 클수록 충격파 직전의 최대 마하수는 커지는 것으로 나타났다.

Computation of aerodynamic coefficients of a re-entry vehicle at Mach 6

  • R.C. Mehta;E. Rathakrishnan
    • Advances in aircraft and spacecraft science
    • /
    • 제10권5호
    • /
    • pp.457-471
    • /
    • 2023
  • The paper evaluates the aerodynamic coefficients on a blunt-nose re-entry capsule with a conical cross-section followed by a cone-flare body. A computer code is developed to solve three-dimensional compressible inviscid equationsfor flow over a Space Recovery Experiment (SRE) configuration at different flare-cone half-angle at Mach 6 and angle of attack up to 5°, at 1° interval. The surface pressure variation is numerically integrated to obtain the aerodynamic forces and pitching moment. The numerical analysis reveals the influence of flare-cone geometry on the flow characteristics and aerodynamic coefficients. The numerical results agree with wind tunnel results. Increase of cone-flare angle from 25° to 35° results in increase of normal force slope, axial forebody drag, base drag and location of centre of pressure by 62.5%, 56.2% and 33.13%, respectively, from the basic configuration ofthe SRE of 25°.

점탄성유체의 저항 및 열전달 감소현상과 퇴화의 영향에 관한 연구 (A Study on the Drag and Heat Transfer Reduction Phenomena and Degradation Effects of the Viscoelastic Fluids)

  • 엄정섭;전찬열;유상신
    • 설비공학논문집
    • /
    • 제2권1호
    • /
    • pp.37-48
    • /
    • 1990
  • The drag and heat transfer reduction phenomena and degradation effects of drag reducing polymer solutions which are known as the viscoelastic fluids are investigated experimentally for the turbulent circular tube flows. Two stainless steel tubes are used for the experimental flow loops. Aqueous solutions of Polyacrylamide Separan AP-273 with concentrations from 300 to 1000 wppm are used as working fluids. Flow loops are set up to measure the friction factors and heat transfer coefficients of test tubes in the once-through system and the recirculating flow system. Test tubes are heated by power supply directly to apply constant heat flux boundary conditions on the wall. Capillary tube viscometer and falling ball viscometer are used to measure the viscous characteristics of fluids and the characteristic relaxation time of a fluid is determined by the Powell-Eyring model. The order of magnidude of the thermal entrance length of a drag reducing polymer solution is close to the order of magnitude of the laminar entrance length of Newtonian fluids. Dimensionless heat transfer coefficients of the viscoelastic non-Newtonian fluids may be represented as a function of flow behavior index n and newly defined viscoelastic Graetz number. As degradation continues viscosity and the characteristic relaxation time of the testing fluids decrease and heat transfer coefficients increase. The characteristic relaxation time is used to define the Weissenberg number and variations of friction factors and heat transfer coefficients due to degradation are presented in terms of the Weissenberg number.

  • PDF

Wind tunnel study of wind loading on rectangular louvered panels

  • Zuo, D.;Letchford, C.W.;Wayne, S.
    • Wind and Structures
    • /
    • 제14권5호
    • /
    • pp.449-463
    • /
    • 2011
  • Drag forces on a rectangular louvered panel, both as a free-standing structure and as a component in a generic low-rise building model, were obtained in a wind tunnel study. When tested in a building model, the porosity ratio of the wall opposite the louvered panel was varied to investigate its effect on the loading of the louvered panel. Both mean and pseudo-steady drag coefficients were obtained. Comparisons with the provisions for porous walls in contemporary loading standards indicate that for some opposite wall porosity ratios, the standards specify significantly different wind loads (larger and smaller) than obtained from this wind tunnel study.

Characteristics of Fluid Flow in the Fluidized Bed Shell and Tube Type Heat Exchanger with Corrugated Tubes

  • Ahn Soo Whan;Bae Sung Taek;Kim Myoung Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.198-205
    • /
    • 2004
  • An experimental study was carried on the characteristics of fluid flow and heat transfer in a fluidized bed shell-and-tube type heat exchanger with corrugated tubes. Seven different solid particles having same volume were circulated in the tubes. The effects of vari­ous parameters such as water flow rates, particle geometries and materials, and geometries of corrugated tubes on relative velocities and drag coefficients were investigated. The present work showed that the drag force coefficients of particles in the corrugated tubes were usually lower than those in the smooth tubes, meanwhile the relative velocities between particles and water in the corrugated tubes were little higher than those in the smooth tubes except the particles of glasses.

벽면근처에 놓인 정방형주의 유체력 제어 (Fluid Force Suppression of a Square Prism near Plane Wall)

  • 김광석;노기덕;강명훈;변용수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.61-62
    • /
    • 2006
  • The suppression of fluid force acting on a square prism near plane wall was studied by attaching fences on the comers of the prism. The height of the fence was 10% of the square width and the range of Reynolds number considered was $Re=2.0{\times}10^4$. The experimental parameters were the attaching position and numbers of fences, the space ratios $G/B(G/B=0.1{\sim}1.2)$ between prism and plane wall. The average drag coefficients were increased and the average hit coefficients were decreased and increased with the space ratios foulard plane wall. The drag of the prism was reduced average 7.6% with the space ratios by attaching the normal fence at the rear and upper comer and the horizontal normal fence at the rear and lower corner on the prism.

  • PDF