• Title/Summary/Keyword: double point

Search Result 729, Processing Time 0.031 seconds

A Study on H-polarized Electromagnetic Scattering by a Resistive Strip Grating Between a Grounded Double Dielectric Layer (접지된 2중 유전체층 사이의 저항띠 격자구조에 의한 H-polarized 전자파 산란에 관한 연구)

  • Yoon, Uei-Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.29-34
    • /
    • 2022
  • In this paper, thr H-polarized scattering problems by a resistive strip grating in a grounded double dielectric layer are analyzed by applying the PMM(point matching method) known as a numerical method of electromagnetic fileld. The boundary conditions are applied to obtain the unknown field coefficients, the scattered electromagnetic fields are expanded in a series of Floquet mode functions, and the resistive boundary condition is applied to analysis of the resistive strip. The %error of the convergence of the reflected power according to the relative permittivity of the dielectric layer and the size of the number of rows in the square matrix was compared, as the size of the number of rows in the square matrix increased, the accuracy of the reflected power increased. As the resistivity of the resistive strip decreased, the thickness of the dielectric layers decreased, and the relative permittivity of the dielectric layers increased, the reflected power increased. The numerical results for the presented structure of this paper having a grounded double dielectric layer are shown in good agreement compared to those of the existing papers.

Analysis of the collar pattern of a double-breasted tailored jacket using virtual fitting - Comparison of collar laying amount according to lapel fold line start position - (가상착의를 활용한 더블브레스트 테일러드 재킷의 칼라 패턴 분석 - 라펠 꺾임선 시작 위치에 따른 칼라의 눕힘 분량 비교 -)

  • Mi Hwa Jun ;Jeongah Jang
    • The Research Journal of the Costume Culture
    • /
    • v.31 no.5
    • /
    • pp.640-650
    • /
    • 2023
  • This study aimed to suggest a suitable collar pattern by visually evaluating the appearance of the amount of collar drape by the starting position of the lapel line of a double-breasted tailored jacket using a 3d virtual fitting program. It created an avatar based on the mean size of women in their 20s (the 8th Size Korea) using clo network (double fastening: 10cm, collar width: 4.5cm, collar stand: 3cm, and lapel width: 8.5cm). The starting of the lapel twist line was waistline level, the 1/2 level of bustline and waistline, or bustline level, and collar laying amount was 4.5, 5.5, 6.5, or 7.5cm. It was evaluated by garment construction experts using 5, 6, and 4 items on the front, sides, and back, respectively. Descriptive statistics, F-test, Duncan-test, and reliability analysis were conducted using SPSS 22. When collar laying amount was 6.5cm, it was best rated regardless of the starting point. Under waist line, when collar laying amount was 6.5cm, it was best rated regardless of the starting point. When collar laying amount was large, the collar's outline length increased, resulting in unnecessary wrinkles from the neckline to the lapel, affecting the overall collar appearance. When collar laying amount was the smallest, the collar was lifted and the width was narrowed, exposing the seam connecting the collar and neckline. The length of the collar's outline varied depending on collar laying amount, which was important to make the outline sit comfortably on the body.

Geometry optimization of a double-layered inertial reactive armor configured with rotating discs

  • Bekzat Ajan;Dichuan Zhang;Christos Spitas;Elias Abou Fakhr;Dongming Wei
    • Advances in Computational Design
    • /
    • v.8 no.4
    • /
    • pp.309-325
    • /
    • 2023
  • An innovative inertial reactive armor is being developed through a multi-discipline project. Unlike the well-known explosive or non-explosive reactive armour that uses high-energy explosives or bulging effect, the proposed inertial reactive armour uses active disc elements that is set to rotate rapidly upon impact to effectively deflect and disrupt shaped charges and kinetic energy penetrators. The effectiveness of the proposed armour highly depends on the tangential velocity of the impact point on the rotating disc. However,for a single layer armour with an array of high-speed rotating discs, the tangential velocity is relatively low near the center of the disc and is not available between the gap of the discs. Therefore, it is necessary to configure the armor with double layers to increase the tangential velocity at the point of impact. This paper explores a multi-objective geometry design optimization for the double-layered armor using Nelder-Mead optimization algorithm and integration tools of the python programming language. The optimization objectives include maximizing both average tangential velocity and high tangential velocity areas and minimizing low tangential velocity area. The design parameters include the relative position (translation and rotation) of the disc element between two armor layers. The optimized design results in a significant increase of the average tangential velocity (38%), increase of the high tangential velocity area (71.3%), and decrease of the low tangential velocity area (86.2%) as comparing to the single layer armor.

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

Comparison of Environmental Conditions and Insulation Effect between Air Inflated and Conventional Double Layer Greenhouse (공기주입 및 관행 이중피복온실의 재배환경 및 단열성능 비교)

  • Jayasekara, Shanika N.;Na, Wook H.;Owolabi, Abdulhameed B.;Lee, Jong W.;Rasheed, Adnan;Kim, Hyeon T.;Lee, Hyun W.
    • Journal of Bio-Environment Control
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2018
  • This study was conducted to determine which greenhouse provided good environmental conditions for strawberry production, and performed better at conserving energy. Temperature, RH, VPD, $CO_2$, solar radiation, yield, and fuel consumption were the parameters analyzed. The temperatures of both greenhouses were well controlled in order to provide optimal day and night temperatures for strawberry production. The air inflated double layer greenhouse had higher RH values (more than 90% at night), which led to higher disease occurrence, in comparison to the conventional double layer greenhouse. Furthermore, the air inflated double layer greenhouse had lower VPD values than the conventional double layer greenhouse. Therefore, better RH and VPD were observed in the conventional double layer greenhouse. Higher $CO_2$ concentration was observed in the air inflated double layer greenhouse while the conventional double layer greenhouse ventilated better than the air inflated greenhouse, because of its side ventilators. Moreover, higher solar radiation in the conventional double layer greenhouse resulted in higher yield, in comparison to the air inflated double layer greenhouse. Thus, we can conclude that the conventional double layer greenhouse provided a better environment for crop growth, in comparison to the air inflated double layer greenhouse. Regarding fuel consumption, the air inflated double layer greenhouse had lower fuel consumption than the conventional double layer greenhouse. Therefore, from an energy consumption point of view, we can conclude that the air inflated double layer greenhouse performed better than the conventional double layer greenhouse.

Improving the Distribution of Temperature by a Double Air Duct in the Air-Heated Plastic Greenhouse (시설내 온도분포 균일화를 위한 온풍난방기용 2중 덕트개발)

  • 김태영;김기덕;조일환;남은영;남윤일;우영회;문보흠
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.162-166
    • /
    • 2004
  • Air temperature variation along the length of the air duct in an air-heated plastic greenhouse was large, 13 ~ 15$^{\circ}C$ between the front and the rear side of a greenhouse. To reduce this temperature variation, a new PE-film air duct having a small duct inside a large duct (double duct) was developed. This double duct was consisted of an inner duct with air outlets at a 0.15 m interval and an outer duct with air outlets at a 2.5 m interval. Diameters of the air outlet holes were 7, 15, and 35 cm from the front to the end of the inner duct film, while identical 10 cm holes were used on the outer duct film. As a result, air temperature was $46^{\circ}C$ at the beginning side and $47^{\circ}C$ at the ending side, while the conventional single duct had $53^{\circ}C$ at the beginning point and $38^{\circ}C$ at the ending point with a variation of $15^{\circ}C$. Height of a cucumber crop grown in a greenhouse with the new double air duct system was 65.5 cm, 14% increase as compared to that in a greenhouse with a conventional air duct system. Total fruit yield per l0a greenhouse in a greenhouse with the new double air duct system was 4,616 kg, which was 17% greater than that in a greenhouse with a conventional air duct system. Amount of heating oil consumption during March 3 to April 24, 2002 was 3,233 L per l0a greenhouse with the new double air duct system, which was 13% less than that with a conventional air duct system.

Characteristics of the ZMP for the biped robot

  • Park, Chan-Soo;Choi, Chong-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.220-224
    • /
    • 2003
  • This is a preliminary study is to make the robot walk more stably by observing the ZMP (Zero Moment Point) of the robot when the robot stands on one leg(single support) and then on two legs(double support) and so on. The robot consists of nine DOF (Degree of freedom) with lower part of the body. It is equipped with motor drivers and force sensors inside the robot. The motors are controlled by the external PC (Intel pentium 4). By the experimental results, it is found that the robot is unstable in the instant of changing from single support to double support or from double support to single support. We use the trajectory compensation of the angle and the length of both legs to realize more stable walking.

  • PDF

Design of filters with double coupled line for PCS (이중결합선로를 이용한 PCS용 여파기의 설계)

  • 이창화;구본희김명수이상석
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.387-390
    • /
    • 1998
  • We propose comb-line filter using SIR(Stepped Impedance Resonator) with two transmission line. The coupling structure of the filter is double coupled line where two coupled lines are linked with cascade. We find out the inverter function of the filter. using even and odd mode impedance. The merits of the filter are that first, we can design transmission zero point at any frequency that we wanted without using lumped elements : chip capacitors and inductors. Second, we can design small size filters. To validate the inverter function of the filter with double coupled line we designed and fabricated two-pole band pass filter with the proposed filter structure.

  • PDF

Noise and Vibration Reduction of Double-Resiliently Mounted Pump-like Machinery (이중탄성지지된 펌프류 장비의 소음.진동 저감)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.124-127
    • /
    • 2006
  • In this paper, noise and vibration reduction of double-resiliently mounted pump-like machinery is studied. SBN(Structure-borne noise) reduction through upper and lower mount is analyzed by assuming that the system is modeled as a mass-spring system. In addition, the impedance of the floor is included in the prediction. The comparison of the SBN difference through upper mount show that the effect of impedance is negligible, while the measurement differs significantly from the prediction for high frequency range. It is found that the assumption of point mass-spring system leads to the disagreement between prediction and measurements.

  • PDF

Generalized Ratio-Cum-Product Type Estimator of Finite Population Mean in Double Sampling for Stratification

  • Tailor, Rajesh;Lone, Hilal A.;Pandey, Rajiv
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.3
    • /
    • pp.255-264
    • /
    • 2015
  • This paper addressed the problem of estimation of finite population mean in double sampling for stratification. This paper proposed a generalized ratio-cum-product type estimator of population mean. The bias and mean square error of the proposed estimator has been obtained upto the first degree of approximation. A particular member of the proposed generalized estimator was identified and studied from a comparison point of view. It is observed that the identified particular estimator is more efficient than usual unbiased estimator and Ige and Tripathi (1987) estimators. An empirical study was conducted in support of the theoretical findings.