• Title/Summary/Keyword: double movement

Search Result 213, Processing Time 0.03 seconds

Numerical Analysis on Plasma Particles inside Electro-magnetic Field Using Particle-in-cell Method (Particle-in-cell 기법을 이용한 전자기장내 플라즈마 입자의 거동 해석)

  • Han, Doo-Hee;Joe, Min-Kyung;Shin, Junsu;Sung, Hong-Gye;Kim, Su-Kyum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.11
    • /
    • pp.932-938
    • /
    • 2017
  • Particle-in-cell method which blends Eulerian grids and Lagrangian particle is utilized to solve simplified hall-effect thruster. Since this study individually tracks not only neutrons and ions but also electrons, message passing interface(mpi) scheme is adopted for parallel computer cluster. Helical movement of an electron cloud in constant magnetic field is validated comparing with an exact solution. A plasma in radial magnetic field and axial electric field in a reaction cylinder is established. Electrons do double helix movement and are well anchored in a cylinder. Ionization of neutrons by impact with high-speed electrons generates ion particles. They are accelerated by axial electric field, which forms a plume of a plasma-effect thruster.

Effect of Heel Height and Speed on Gait, and the Relationship Among the Factors and Gait Variables

  • Park, Sumin;Park, Jaeheung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.39-52
    • /
    • 2016
  • Objective: This paper investigates gait changes according to different heel heights and speeds, and the interaction between the effects of the heel height and the speed during walking on stride parameters and joint angles. Furthermore, the relationship among heel height, speed and gait variables is investigated using linear regression. Background: Gait changes by heel height or speed have been studied respectively, but has not been reported whether there is an interaction effect between heel height and speed. It would be necessary to understand how gait changes when a person wears heels in different heights at various speeds, for example, high-heeled walking at fast speed, since it may cause unusual gait patterns and musculoskeletal disorders. Method: Ten females were asked to walk at five fixed cadences (94, 106, 118, 130 and 142 steps/min.) wearing three shoes with different heel heights (1, 5.4 and 9.8cm). Nineteen gait variables were analyzed for stride parameters and joint angles using two-way repeated measure analysis of variance and regression analysis. Results: Both heel height and speed affect movement of ankle, knee, spine and elbow joint, as well as stride length and Double/Single support time ratio. However, there is no significant interaction effect between heel height and speed. The regression result shows linear relationships of gait variables with heel height and speed. Conclusion: Heel height and speed independently affect stride parameters and joint angles without a significant interaction, so the gait variables are linearly amplified or diminished by the two factors. Application: Walking in high heels at fast speed should be careful for musculoskeletal disorders, since the amplified movement of knee and spine joint can lead to increased moment. Also, the result might give insight for animators or engineers to generate walking motion with high heels at various speeds.

Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer (디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석)

  • Chang, Woo-Nam;Lee, Kyoung-Bo;Yeom, Jun-Woo;Hwang, Byong-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

The Effect of Types of Initial Drive-in Steps on Technical Factors in Basketball

  • Park, Sangheon;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.3
    • /
    • pp.181-185
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effect of types of drive-in initial steps in basketball on technical factors, to provide basic information for the enhancement of basketball skill. Method: Ten men (age: $24.70{\pm}2.26years$; height: $181.00{\pm}5.72cm$; weight: $75.70{\pm}8.23kg$; career length: $10.00{\pm}3.59years$), each with a career length of over five years and no history of injury to the lower extremities within the prior six months, participated in this study. They were asked to perform four types of drive-in movements at $35{\sim}60^{\circ}$, wearing their own shoes, after running from a start line 5 m away and catching a basketball passed by an expert passer. The drive-in movements were measured by eight infrared cameras (Oqus 300, Qualisys, Sweden). Collected raw data were used to calculate total initial step time, displacement, velocity, center of mass (COM) height, and COM velocity. Results: Total initial step displacement and velocity of cross drive-ins (JC, SC) were greater than that of direct drive-ins (JD, SD; p < .05). COM velocity of cross drive-ins (JC, SC) was also greater than that of direct drive-ins (JD, SD; p < .05). Conclusion: Our results indicated that cross drive-ins, regardless of stop step type, are more effective than direct drive-ins. This is because cross drive-ins are technically bold due to less influence from walking violations and double dribble rules in basketball. However, using one-sided movement is too difficult to play in competitive game; therefore, basketball players should develop the ability to choose appropriate movement frequency.

Visualization and Flowfield Measurements of the Vortical Flow over a Double-Delta Wing

  • Sohn, Myong-Hwan;Jang, Young-IL
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.1
    • /
    • pp.63-74
    • /
    • 2003
  • The vortical flow of a 65-deg flat plate delta wing with a leading edge extension(LEX) was examined through off-surface visualization, 5-hole probe and hot-film measurements. The off-surface flow visualization technique used micro water droplets generated by a home-style ultrasonic humidifier and a laser beam sheet. The angles of attack ranged from 10 to 30 degrees, and the sideslip angles ranged from 0 to -15 degrees. The Reynolds number was $1.82{\times}10^5$ for the flow visualization, and $1.76{\times}10^6$ for the 5-hole probe and hot-film measurements. The comparison of the visualization photos and the flow field measurement showed that the two results were in a good agreement for the relative position and the structure of the wing and LEX vortices, even though the flow Reynolds numbers of the two results were much different. The wing vortex and the LEX vortex coil each other while maintaining a comparable strength and identity at zero sideslip. Neither a looping of the wing vortex around the strake vortex, nor the lopsided coiling of the stronger strake and the weaker wing vortices was observed. At non-zero sideslip, the downward movement of the LEX vortex when going downstream was enhanced on the windward side, and the downward and inboard movement of the LEX vortex when going downstream was suppressed on the leeward side. The counterclockwise coiling of the wing and LEX vortices was decreased significantly on the leeward side.

Numerical simulation on mining effect influenced by a normal fault and its induced effect on rock burst

  • Jiang, Jin-Quan;Wang, Pu;Jiang, Li-Shuai;Zheng, Peng-Qiang;Feng, Fan
    • Geomechanics and Engineering
    • /
    • v.14 no.4
    • /
    • pp.337-344
    • /
    • 2018
  • The study of the mining effect influenced by a normal fault has great significance concerning the prediction and prevention of fault rock burst. According to the occurrence condition of a normal fault, the stress evolution of the working face and fault plane, the movement characteristics of overlying strata, and the law of fault slipping when the working face advances from footwall to hanging wall are studied utilizing UDEC numerical simulation. Then the inducing-mechanism of fault rock burst is revealed. Results show that in pre-mining, the in situ stress distribution of two fault walls in the fault-affected zone is notably different. When the working face mines in the footwall, the abutment stress distributes in a "double peak" pattern. The ratio of shear stress to normal stress and the fault slipping have the obvious spatial and temporal characteristics because they vary gradually from the higher layer to the lower one orderly. The variation of roof subsidence is in S-shape which includes slow deformation, violent slipping, deformation induced by the hanging wall strata rotation, and movement stability. The simulation results are verified via several engineering cases of fault rock burst. Moreover, it can provide a reference for prevention and control of rock burst in a fault-affected zone under similar conditions.

Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia (신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현)

  • Shin, Hyo-Seob;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.459-462
    • /
    • 2010
  • Response to nerve stimulation platform for implementing measures to detect finger movement has been functioning as an important factor. This stimulated finger on the nerve and muscle responses would vary. In other words, the finger movement of the muscle response to nerve stimulation and sensing Actuator for the H/W development is needed. In addition, a low power embedded CPU based on the top was used. H/W configuration portion of the isolation power, constant current control, High impedance INA, amplifier parts, and the stimulus mode and the Micro-control the status of current, AD converter Low Data obtained through the processing system is implemented.

  • PDF

Case Report: Miller Fisher Syndrome (한방치료로 호전된 Miller Fisher 증후군 환자 증례보고)

  • Ryu, Ju-young;Lee, Kang-wook;Cho, Min-kyoung;Cho, Hyun-kyoung;Yoo, Ho-ryong;Seol, In-chan;Kim, Yoon-sik
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.4
    • /
    • pp.661-668
    • /
    • 2016
  • Objectives: To describe the effect of traditional Korean medicine and treatment on Miller Fisher syndrome (MFS).Methods: A 54-year-old woman diagnosed with MFS presented with eyeball dysfunction, diplopia, vertigo, right facial palsy, and back dysesthesia. The patient had been treated with immunoglobulin for 21 d, but her symptoms failed to improve. Thus, herbal medicine, acupuncture, electropuncture, pharmacopuncture, and moxibustion were added. Length of eyeball movement, distance that the patient recognize double images in the eyes and Visual Analogue Scale (VAS) are measures for the syndrome.Results: The symptoms of the patient considerably improved, with the return of eyeball movement to normal and disappearance of diplopia.Conclusions: The results suggest that Korean medicine may be an effective therapy for MFS.

Product Characteristics Assessment and Wearing Evaluation of Waist-protection Corset Design (허리보호 코르셋 디자인을 위한 제품 분석 및 착용 평가)

  • Kim, Soyoung;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.23 no.6
    • /
    • pp.781-789
    • /
    • 2021
  • To enhance the design and comfort of waist-protection corsets, this study analyzed the product characteristics of five types of posture-correction corsets that are available commercially. Additionally, subjective evaluation of the corsets was conducted on women aged 20 to 60 years, in terms of design, material preference, fit, comfort, degree of correction, freedom of movement, tightness, and convenience of front fastening. Following product analysis, the five corset types were divided into: two soft, one semi-hard, and two hard types in terms of the degree of elongation. As a result of pattern analysis, the soft type was designed to improve fit by reflecting the body curvature, whereas the semi-hard and hard types were relatively flat. Through the wearing sensation assessment, the hard type manufactured by company S was the best in terms of design, material, fit, comfort, correction degree, and freedom of movement. The soft type was average in design, material, and fit while relatively poor in the correction degree and tightness. The results indicated that soft materials, flexible bones with appropriate tension, patterns designed to snugly fit the body with large curvature at the top and bottom for better inflection, and adjustable support belts that can be double-fixed are crucial elements in improving the corset design to boost the comfort of wearing. These study results are helpful in the development of waist-protection corsets with excellent wearing comfort and design appreciated by customers.

A Study on Micro-Mobility Pattern Analysis using Public Bicycle Rental History Data (공공자전거 임대내역 데이터를 활용한 마이크로 모빌리티 패턴분석 연구)

  • Cho, Jaehee;Baik, Gaeun
    • Journal of Information Technology Services
    • /
    • v.20 no.6
    • /
    • pp.83-95
    • /
    • 2021
  • In this study, various usage patterns were analyzed after establishing a data mart for micro mobility analysis based on the rental history of public bicycles in Seoul. Rental history data is origin-destination data that includes the rental location and time, and the return location and time. About 1500 rental locations were classified according to the characteristics of the location to create a 'station type' dimension. We also created a 'path type' dimension that displays whether the rental location and return location are the same. In addition, a derived variable called speed, which is obtained by dividing the distance used by the time used, is added, and through this, the characteristics of the riding area and the reason for the rental can be estimated. Meanwhile, administrative district link, administrative neighborhood link, and station type link were created to apply network analysis. Through this analysis, the roles and proportions of administrative districts, public facilities, and private facilities engaged in micro-mobility services were visualized. 49.9% of rentals occur at rental offices near transportation facilities, and half of them occur at rental offices near subway stations. The number of rentals during the evening rush hour is more than double that of the morning rush hour. When the path type is unidirectional, there is a fixed destination, so the distance and time used are short, and the movement speed tends to be high. In the case of round-trip, the purpose of use is exercise or leisure, so the distance and time used are long, and the movement speed is slow. It is expected that the results of the analysis can be used as reference materials for selecting new rental locations, providing convenient services for users, and developing user-specialized products.