• Title/Summary/Keyword: double link

Search Result 146, Processing Time 0.033 seconds

A Novel Active Boost Power Converter for single phase SRM (단상 SRM 구동을 위한 새로운 능동 부스트 전력 컨버터)

  • Seok, Seung-Hun;Liang, Jianing;Lee, Dong-Heeㅋ;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.277-279
    • /
    • 2008
  • In this paper, a novel active boost converter for SR drive is proposed. An active capacitor circuit is added in the front-end. Based on this active capacitor network, when boost switch turns off, this network seems as passive capacitor network. And the voltage of boost capacitor can keep balance with dc-link voltage automatically. In the capacitor network, discharging voltage is general dc-link voltage in parallel-connected capacitors; charging voltage is double dc-link voltage in series-connected capacitors. When boost switch turns on, two capacitors are connected in series, and discharging voltage is up to double dc-link voltage. So the fast excitation current can be obtained from this mode. Profit from fast excitation and fast demagnetization mode, the performance and output power can be improved. Some computer simulations are done to verify the performance of proposed converter.

  • PDF

Attitude Control of The Double Inverted Pendulum with Compliant Joint (순응성 관절을 갖는 2축 도립 진자의 자세 제어)

  • Jeon, Se-Joong;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2983-2985
    • /
    • 1999
  • This paper presents the attitude control of the double inverted pendulum with compliant joint. The biped robot with compliant ankle joint instead of a motor have a good contact between it's sole and ground in the uneven ground. The compliant ankle joint proposed here is composed of springs and mechanical constraint. The lower link is hinged on the plate to free for rotation in the vertical plate. The upper link is connected to the lower link through a DC motor. The DC motor is used to control the posture of the pendulum by adjusting the position of the upper link. The algorithm for controlling a proposed inverted pendulum is nonlinear feedback controller. Simulation with mathematical model are conducted to show the validity of the proposed controller.

  • PDF

Design of Self-Healing Algorithm for Double Link Failure in SONET (SONET 망에서의 이중 장애 복구 알고리즘의 설계)

  • Han, Kyoung-Heum;Koh, Jai-Sang;Cho, Choong-Ho
    • IE interfaces
    • /
    • v.9 no.3
    • /
    • pp.52-63
    • /
    • 1996
  • DCS(Digital Cross-connect System)를 이용한 다이나믹 자체 치유 알로리즘들은 주로 대상을 하나의 링크 장애에 대해서 완전 복구될 수 있는 예비 용량을 갖는 망을 대상으로 복구 시간을 줄이는 방향들이 제시되어 왔으나, 이러한 고장난 망의 복구를 위한 자체 치유 복구 알고리즘의 효율성은 이중 장애나 노드 장애에 적용 되었을 때의 복구율을 가지고 평가가 된다. 본 논문에서는 단일 링크(single link) 장애뿐만 아니라 이중 링크(double link) 장애에 대해서도 망의 복구 허용시간 내에서 복구율을 높이는 새로운 망복루 알로리즘을 제안한다. 이를 위해서 망의 복구 허용 시간 내에, 전체적인 예비 용량을 고려하여 선택된 복구 경로의 각 링크의 부하를 균등하게 하는 복구 방법을 적용한다. 또한 제안된 알고리즘의 시뮬레이션 결가를 기본의 복구 방법과 비교 분석한다.

  • PDF

Extraction of Design Parameters through Electromagnetic and Dynamic Analysis of Slotless Double-side PMLSM system (양측식 영구자석 가동형 슬롯리스 직선 동기전동기의 전자기 특성 및 동특성 해석에 의한 설계정수 도출)

  • Jang, Won-Bum;Lee, Sung-Ho;Jang, Seok-Myeong;You, Dae-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2135-2144
    • /
    • 2007
  • This paper presents system design of the slotless double-side Permanent Magnet Linear Synchronous Machine system (PMLSM) through magnetic field analysis and dynamic modeling. In our analysis, 2-D analytical treatments based on the magnetic vector potential were adopted to predict magnetic field with space harmonics by PM mover magnetization and stator winding current. From these, the design parameters such as inductance, Back-emf, and thrust are estimated. And, the electrical dynamic modeling including synchronous speed is completed by calculation of a DC link voltage in effort to obtain the accurate mechanical power from Space Vector Pulse Width Modulation(SVPWM). Therefore, the system design of PMLSM is performed from estimation of design parameters according to PM size and coil turns in magnetic field and from calculation of a DC link voltage to satisfy base speed and base thrust represented as the maximum output power in dynamic modeling. The estimated values from the analysis are verified by the finite element method and experimental results.

Robust Design of Descending Lifeline Using Double Square Linkage Mechanism (이중 4절링크 기구를 이용한 완강기 강건 설계)

  • Park, Jung-Woo;Yun, Seul-Gi;Jung, Geun-Hak;Jung, Min-Hee;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.6
    • /
    • pp.108-113
    • /
    • 2021
  • Recently, a new concept of a one-touch descending lifeline has been proposed to address the drawbacks of the conventional descending lifeline, which can be easily installed and quickly evacuated in the case of a fire emergency. All separate parts for escape are initially mounted in a box, and the link-type support is spread out of the window by pushing the handle attached to the box. In this study, the proposed double square linkage mechanism was redesigned, and its safety is verified by determining an appropriate moment of inertia of the link through finite element analysis using Abaqus. The shape and assembling method of the reel and speed controller were also modified such that the safety belt was simultaneously unfolded with link-type support. Finally, the feasibility of the proposed one-touch all-in-one descending lifeline was confirmed through fabrication.

Double Boost Power-Decoupling Topology Suitable for Low-Voltage Photovoltaic Residential Applications Using Sliding-Mode Impedance-Shaping Controller

  • Tawfik, Mohamed Atef;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.881-893
    • /
    • 2019
  • This paper proposes a practical sliding-mode controller design for shaping the impedances of cascaded boost-converter power decoupling circuits for reducing the second order harmonic ripple in photovoltaic (PV) current. The cascaded double-boost converter, when used as power decoupling circuit, has some advantages in terms of a high step-up voltage-ratio, a small number of switches and a better efficiency when compared to conventional topologies. From these features, it can be seen that this topology is suitable for residential (PV) rooftop systems. However, a robust controller design capable of rejecting double frequency inverter ripple from passing to the (PV) source is a challenge. The design constraints are related to the principle of the impedance-shaping technique to maximize the output impedance of the input-side boost converter, to block the double frequency PV current ripple component, and to prevent it from passing to the source without degrading the system dynamic responses. The design has a small recovery time in the presence of transients with a low overshoot or undershoot. Moreover, the proposed controller ensures that the ripple component swings freely within a voltage-gap between the (PV) and the DC-link voltages by the small capacitance of the auxiliary DC-link for electrolytic-capacitor elimination. The second boost controls the main DC-link voltage tightly within a satisfactory ripple range. The inverter controller performs maximum power point tracking (MPPT) for the input voltage source using ripple correlation control (RCC). The robustness of the proposed control was verified by varying system parameters under different load conditions. Finally, the proposed controller was verified by simulation and experimental results.

Hybrid Double Direction Blocking Sub-Module for MMC-HVDC Design and Control

  • Zhang, Jianpo;Cui, Diqiong;Tian, Xincheng;Zhao, Chengyong
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1486-1495
    • /
    • 2019
  • Dealing with the DC link fault poses a technical problem for an HVDC based on a modular multilevel converter. The fault suppressing mechanisms of several sub-module topologies with DC fault current blocking capacity are examined in this paper. An improved half-bridge sub-module topology with double direction control switch is also designed to address the additional power consumption problem, and a sub-module topology called hybrid double direction blocking sub module (HDDBSM) is proposed. The DC fault suppression characteristics and sub-module capacitor voltage balance problem is also analyzed, and a self-startup method is designed according to the number of capacitors. The simulation model in PSCAD/EMTDC is built to verify the self-startup process and the DC link fault suppression features.

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

Double Two Switch Forward Transformer-Linked Soft-Switching PWM DC-DC Power Converter with Tapped Inductor Filters

  • Moisseev Serguei;Koudriavtsev Oleg;Hiraki Eiji;Nakamura Mantaro;Nakaoka Mutsuo;Hamada Satoshi
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.193-197
    • /
    • 2001
  • This paper presents a novel circuit topology of the double two-switch forward type high frequency transformer linked soft-switching PWM DC-DC power converter with tapped inductor filters that can operate under a condition of the low peak voltage stress across the power semiconductor devices and lowered peak current stress through the transformer for some high power applications. This circuit topology of an interleaved two-switch forward soft-switching power converter is proposed in the order to minimize an idle circulating current due to the tapped inductor filter without of any additional active auxiliary resonant-assisted snubber circuits, such as active resonant DC link snubbers and AC link snubbers, active resonant commutation leg link snubbers. The unique advantages of this power converter are less power circuit components and power semiconductor devices, constant frequency PWM scheme, cost effective configuration and wider soft-switching PWM operation range under PWM power regulations load variations. The practical effectiveness of the proposed soft-switching converter circuit topology is tested by simulations and is proved by experimental results received from the 500W-100kHz breadboard setup.

  • PDF

A Study on the Optimal Signal Timing for Area Traffic Control (지역 교통망 관리를 위한 최적 신호순서에 관한 연구)

    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.24 no.2
    • /
    • pp.69-80
    • /
    • 1999
  • A genetic algorithm to determine the optimal signal sequence and double cycle pattern is described. The signal sequence and double cycle pattern are used as the input for TRANSYT to find optimal signal timing at each junction in the area traffic networks, In the genetic process, the partially matched crossover and simple crossover operators are used for evolution of signal sequence and double cycle pattern respectively. A special conversion algorithm is devised to convert the signal sequence into the link-stage assignment for TRANSYT. Results from tests using data from an area traffic network in Leicester region R are given.

  • PDF