• Title/Summary/Keyword: double exposure

Search Result 218, Processing Time 0.031 seconds

A CMOS active pixel sensor with embedded electronic shutter and A/D converter (전자식 셔터와 A/D 변환기가 내장된 CMOS 능동 픽셀 센서)

  • Yoon, Hyung-June;Park, Jae-Hyoun;Seo, Sang-Ho;Lee, Sung-Ho;Do, Mi-Young;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.272-277
    • /
    • 2005
  • A CMOS active pixel sensor has been designed and fabricated using standard 2-poly and 4-metal $0.35{\mu}m$ CMOS processing technology. The CMOS active pixel sensor has been made up of a unit pixel having a highly sensitive PMOSFET photo-detector and electronic shutters that can control the light exposure time to the PMOSFET photo-detector, correlated-double sampling (CDS) circuits, and an 8-bit two-step flash analog to digital converter (ADC) for digital output. This sensor can obtain a stable photo signal in a wide range of light intensity. It can be realized with a special function of an electronic shutter which controls the light exposure-time in the pixel. Moreover, this sensor had obtained the digital output using an embedded ADC for the system integration. The designed and fabricated image sensor has been implemented as a $128{\times}128$ pixel array. The area of the unit pixel is $7.60{\mu}m{\times}7.85{\mu}m$ and its fill factor is about 35 %.

An ESR Study of Amino Acid and Protein Free Radicals in Solution Part VI. Enzymatic Inactivation of Lysozyme in Aqueous Solution Resulting from Exposure to $Ti-H_2O_2$ System and Gamma-Irradiation

  • Hong, Sun-Joo;Piette, L.H.
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.2
    • /
    • pp.80-83
    • /
    • 1972
  • The activity change of lysozyme resulted from its exposure to $Ti-H_2O_2$system in aqueous liquid at room temperature and to ${\gamma}$-irradiation in ice at $195^{\circ}K$ has been measured at room temperature with a Cary-14 spectrophotometer. The enzymatic activity of lysozyme which had been added to a previously flow-mixed solution of $TiCl_3$ and $H_2O_2$ (System I) was compared with the activity of a lysozyme-$H_2O_2$ solution after flow-mixing with $TiCl_3$ (System II), considering the differences between these two activity changes as the extent of the enzymatic inactivation by the involvement of OH radical reaction. The fraction of lysozyme inactivated by OH radical in the system containing 0.0025 M $TiCl_3-0.1M$ $H_2O_2$ (ph 3.5) was 13%, When the $TiCl_3$ concentration is double (pH 3.0), the fraction of enzyme inactivated increases to 36%. The activity of the system containing 0.025 M $TiCl_3-0.1$ M $H_2O_2$ (pH 1.5) was essentially zero. The results seem to support the previos view that the production of OH radical should be proportional to $TiCl_3$ concentration when $H_2O_2$ is present in excess. Increase in the extent of inactivation found in system I with increasing $TiCl_3$ concentration may be due to a pH effect. $H_2O_2$ seems to be less effective than $TiCl_3$ in the inactivation. 1% lysozyme solution, when ${\gamma}$-irradiated with a total dose of 3M rads, loses about 20% of its activity. Lowering of temperature also was found to yield a reduction in enzymatic activity.

  • PDF

A study on the high transparent and antistatic thin films on sodalime glass by reactive pulsed DC magnetron sputtering (Pulsed DC 마그네트론 스퍼터링으로 제조한 소다라임 유리의 고투과 및 대전방지 박막특성 연구)

  • Jung, Jong-Gook;Lim, Sil-Mook
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.353-362
    • /
    • 2022
  • Recently, transmittance of photomasks for ultra-violet (UV) region is getting more important, as the light source wavelength of an exposure process is shortened due to the demand for technologies about high integration and miniaturization of devices. Meanwhile, such problems can occur as damages or the reduction of yield of photomask as electrostatic damage (ESD) occurs in the weak parts due to the accumulation of static electricity and the electric charge on chromium metal layers which are light shielding layers, caused by the repeated contacts and the peeling off between the photomask and the substrate during the exposure process. Accordingly, there have been studies to improve transmittance and antistatic performance through various functional coatings on the photomask surface. In the present study, we manufactured antireflection films of Nb2O5, | SiO2 structure and antistatic films of ITO designed on 100 × 100 × 3 mmt sodalime glass by DC magnetron sputtering system so that photomask can maintain high transmittance at I-line (365 nm). ITO thin film deposited using In/Sn (10 wt.%) on sodalime glass was optimized to be 10 nm-thick, 3.0 × 103 𝛺/☐ sheet resistance, and about 80% transmittance, which was relatively low transmittance because of the absorption properties of ITO thin film. High average transmittance of 91.45% was obtained from a double side antireflection and antistatic thin films structure of Nb2O5 64 nm | SiO2 41 nm | sodalime glass | ITO 10 nm | Nb2O5 64 nm | SiO2 41 nm.

The Study on Design of Customized Radiation Protective Layer for Medical Radiation Dose Reduction (의료방사선 피폭선량 저감을 위한 맞춤형 차폐재 설계에 관한 연구)

  • Kang, Sang-Sik;Kim, Kyo-Tae;Noh, Si-Cheol;Jung, Bong-Jae;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.333-338
    • /
    • 2014
  • The fact is that in addition to an increase in social needs that must be managed systematically unnecessary exposure in the field of medical Recent important that the shield has emerged. However, products that are now in practical use, are not subdivided as compared to various medical radiology. Therefore, in the present study, we tried to present with the help of Monte Carlo simulation the structure of the shielding material that has been optimized. Simulated estimation result, the energy of the mammography for (30 kVp) spectrum, check the shielding rate of 90% or more $30{\mu}mPb$, at 2 mmAl case of shielding material of a single, at design time of 1 mmAl and 0.03 mmPb a double shield structure it is determined that more efficient. Also, check the blocking rate of 90% or more $340{\mu}mPb$, at 30 mmAl energy captured general in (80 kVp) spectra, it is considered that a double shield structure, design 1 mmAl and 0.3 mmPb is useful. These results, be used as basic material for the development of commercialization customized products for dose reduction is expected.

THE EFFECT OF GENETIC VARIATION IN THE DNA BASE REPAIR GENES ON THE RISK OF HEAD AND NECK CANCER (DNA 염기손상 치유유전자의 변이와 두경부암 발생 위험성)

  • Oh, Jung-Hwan;Yoon, Byung-Wook;Choi, Byung-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.509-517
    • /
    • 2008
  • DNA damage accumulates in cells as a result of exposure to exogenous agents such as benzopyrene, cigarette smoke, ultraviolet light, X-ray, and endogenous chemicals including reactive oxygen species produced from normal metabolic byproducts. DNA damage can also occur during aberrant DNA processing reactions such as DNA replication, recombination, and repair. The major of DNA damage affects the primary structure of the double helix; that is, the bases are chemically modified. These modification can disrupt the molecules'regular helical structure by introducing non-native chemical bonds or bulky adducts that do not fit in the standard double helix. DNA repair genes and proteins scan the global genome to detect and remove DNA damage and damage to single nucleotides. Direct reversal of DNA damage, base excision repair, double strand break. DNA repair are known relevant DNA repair mechanisms. Four different mechanisms are distinguished within excision repair: direct reversal, base excision repair, nucleotide excision repair, and mismatch repair. Genetic variation in DNA repair genes can modulate DNA repair capacity and alter cancer risk. The instability of a cell to properly regulate its proliferation in the presence of DNA damage increase risk of gene mutation and carcinogenesis. This article aimed to review mechanism of excision repair and to understand the relationship between genetic variation of excision repair genes and head and neck cancer.

Studies on the Immunization Against Newcastle Disease III. Investions on the Immunity of Newcatle Disease with Special Reference to Vaccination Program and Route (뉴캣슬병 면역에 대한 검토 III. 예방접종 프로그램과 접종경노를 중심으로 한 뉴캣슬병 면역능 검토)

  • 이학철;정유열
    • Korean Journal of Poultry Science
    • /
    • v.8 no.2
    • /
    • pp.77-89
    • /
    • 1981
  • The experimental study was undertaken to confirm the effect of vaccination of birds with Newcastle disease (ND) vaccines on the Market by use of th. various vaccination programs. Sixteen groups of birds varying from 2 to f days of age, which were originated from hyper-immunised hens against ND were immunised by three different ways, a live vaccine only, a killed vaccine only, and the combination of a live and killed vaccine according to the each schedule of employed programs. In the administration of a live vaccine only, birds were immunized by one of following methods, the combination of intranasal and intraocular inoculation, intramuscular inoculation, via drinking water and the double inoculation by spray and drinking water application. Except for the double application, all the birds were vaccinated 2,3 or 4 times with two volumes of the virus dose (drinking water application) instructed by the commercial vaccine laboratory, until 21, 28 or 30 days of age, and all the immunized birds 19, 21 or 28 days postvaccination were challenged intramuscularly with 1.0$m\ell$ of 10,000 MLD per $m\ell$ of a virulent ND virus. In the administration of the combination of a live and killed vaccine, birds were immunized 2 or 3 times intranasally at first until 14 or 28 days of age with the same dose of the above experiment of a live vaccine, and then inoculated intramuscularly 1 or 2 times until 60 days of age with 1.0 $m\ell$ of a killed vaccine. And all immunized birds 11 days postvaccination were challenged with the same procedure of the above experiment. In the administration of a killed vaccine only, birds were immunized 3 times intramuscularly until 28 days of age with varied dose (0.2-0.5 $m\ell$) of a killed vaccine and all immunized birds 33 days postvaccination were challenged with the same procedure of the above experiment. The results obtained are summerised as follows: All birds vaccinated by using the combination of a live and killed vaccine program or a killed vaccin only appeared to be refractory. without any sign of illness, to the challenge exposure with 1.0$m\ell$ of 10,000 MLD per $m\ell$ of a virulent ND virus. On the other hand, the survival rates of birds of live vaccine groups immunized by a number of vaccine program such as Salsbury's day old program, 3-3-3 program, the Institute of Veterinary Reserch program and Multiple inoculation program, were 39.58%, 43.7%, 43.75% and 47.80%, respectively. And the survival rates of birds vaccinated with a live vaccine by 4 different ways of administration, i.e., double inoculation by water and aerosol application, intramuscular injection, intranasal instillation and via 4.inking water were 87.50%, 64.06%, 42.18% and 25.00%, respectively.

  • PDF

Superior Gluteal Artery Perforator Turn-Over Flap Coverage for Lumboscaral Soft Tissue Defect in Ambulatory Patient (보행 환자에서의 위볼기동맥천공지뒤집기피판을 이용한 허리엉치 부위 연부조직 결손의 치료)

  • Moon, Suk-Ho;Kim, Dong-Seok;Oh, Deuk-Young;Lee, Jung-Ho;Rhie, Jong-Won;Seo, Je-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.712-716
    • /
    • 2010
  • Purpose: Extensive lumbosacral defects after removal of spinal tumors have a high risk of wound healing problems. Therefore it is an effective reconstructive strategy to provide preemptive soft tissue coverage at the time of initial spinal surgery, especially when there is an instrument exposure. For soft tissue reconstruction of a lumbosacral defect, a variation of the gluteal flap is the first-line choice. However, the musculocutaneous flap or muscle flap that is conventionally used, has many disadvantages. It damages gluteus muscle and causes functional disturbance in ambulation, has a short pedicle which limits areas of coverage, and can damage perforators, limiting further surgery that is usually necessary in spinal tumor patients. In this article, we present the superior gluteal artery perforator turn-over flap that reconstructs complex lumbosacral defects successfully, especially one that has instrument exposure, without damaging the ambulatory function of the patient. Methods: A 67 year old man presented with sacral sarcoma. Sacralectomy with L5 corpectomy was performed and resulted in a $15{\times}8\;cm$ sized complex soft tissue defect in the lumbosacral area. There was no defect in the skin. Sacral stabilization with alloplastic fibular bone graft and reconstruction plate was done and the instruments were exposed through the wound. A $18{\times}8\;cm$ sized superior gluteal artery perforator flap was designed based on the superior gluteal artery perforator and deepithelized. It was turned over 180 degrees into the lumbosacral dead space. Soft tissue from both sides of the wound was approximated over the flap and this provided in double padding over the instrument. Results: No complications such as hematoma, flap necrosis, or infection occurred. Until three months after the resection, functional disturbances in walking were not observed. The postoperative magnetic resonance imaging scan shows the flap volume was well maintained over the instrument. Conclusion: This superior gluteal artery perforator turn-over flap, a modification of the conventional superior gluteal artery perforator flap, is a simple method that enabled the successful reconstruction of a lumbosacral defect with instrument exposure without affecting ambulatory function.

A Study of Explosion Risk Assessment for Designation of Dangerous Goods Transshipment Pier at Ulsan Port (울산항 위험물 환적부두 지정을 위한 폭발 위험성 평가에 관한 연구)

  • Kang, Min-Kyoon;Lee, Yun-Sok;Ahn, Young-Joong
    • Journal of Navigation and Port Research
    • /
    • v.45 no.3
    • /
    • pp.109-116
    • /
    • 2021
  • The explosion of a chemical tanker ship during cargo transshipment via double-banking at Ulsan Port, resulted in major damage including fires involving nearby ships. As a follow-up measure to prevent the recurrence of similar accidents, the 'Safety Management of Dangerous Goods in Port' was established, and the designation of a transshipment pier for dangerous goods is required given the risk of explosion and the impact on major facilities in the port. This study evaluated the Fire & Explosion Index of major transshipment cargoes in Ulsan Port to design a transshipment pier based on the Explosion Risk Assessment. Based on the results of Fire & Explosion Index evaluation of styrene monomer and benzene, severe explosion risk was confirmed, and the exposure radius was calculated. Based on the results of the exposure radius, the risk range for each major pier was calculated, and 12 terminals were proposed as transshipment pier candidates considering port facilities, surrounding dangerous facilities, and residential aspects. Since the results of the study suggest transshipment piers based on the risk radius alone, maritime traffic safety, pier and mooring facilities, safety facilities and accessibility for emergency response should be considered comprehensively to designate actual transshipment piers.

IMRT 위한 MLC QA Device 제작

  • 심재구;주상규;박영환
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.47-50
    • /
    • 2001
  • Purpose : 체내에서 optimal한 dose distribution을 얻기 위해 도입된 IMRT를 시행할 때 사용하는 MLC는 기계특성상 장기적인 check와 교정을 요한다. 또한 MLC는 static하지 않고 dynamic하기 때문에 leaf position의 실제 위치가 매우 중요하다. MLC QA를 위해 QA 소요시간 및 노력이 많이 MLC position check 요구되는 불편이 있어, 삼성서울 병원에서 필름을 이용한 MLC position check device를 제작하여 간편하게 사용하고 그 우수성에 대해 결과를 보고하고자 한다. Materials and Method : MLC position을 check하기위해 사각형 의 device(acryl:$40{\times}40{\times}5cm$)를 제작하였다. position check device의 정확도를 위해 표면에 real scale 표시용으로 Pb marker를 2cm 간격으로 부착하였다. MLC QA film은 마주보는 (opposite) MLC leaf의 간격이 4mm로 set up한 상태에서 double exposure하여 marker를 이용하여 오차를 분석하였다. MLC position check device의 효율성을 평가하기위해 6MV photon으로 10번 반복 실험을 실시하여 MLC leaf의 평균오차를 조사하고 조사에 걸린 시간을 비교하여 유용성을 평가하였다. Results : 실험결과 MLC leaf의 평균오차를 조사하고 조사에 걸린 시간을 비교하여 유용성을 평가하였다. 범위는 1.45mm였고, 최소 오차는 0.34mm로 나타났다. 1회 조사에 걸린 시간은 평균적으로 약 30분 정도 소요되었다. MLC position check device의 효율성을 평가한 결과오차의 반복성은 관찰되지 않았다. Conclusion : MLC leaf position의 정기적인 check와 교정을 위해 본원에서는 주1회 정기 position error를 check하고 있으며, 평균 월1회 교정을 한다. 본 실험을 통해 MLC position check device를 사용하여 leaf 오차가 2mm이하의 만족할 만한 결과를 얻었다. 또한 MLC position check device를 사용하면 짧은 시간에 모든 leaf의 position error를 쉽게 측정할 수 있고 한 장의 필름으로 모든 결과를 평가할 수 있어 경제성 및 업무의 효율성도 높일 수 있었다.

  • PDF

A LASER HOLOGRAPHIC STUDY ON THE INITIAL REACTION OF MAXILLOFACIAL COMPLEX TO MAXILLARY PROTRACTION (상악 전방견인시 악안면골의 초기반응에 관한 Laser Holography연구)

  • Kang, Hung Sok
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.367-385
    • /
    • 1988
  • In case of skeletal Class III malocclusion with underdeveloped maxilla, the extraoral orthopedic force for the stimulation of maxillary growth or anterior reposition of the maxilla has been used clinically for the improvement of facial skeletal relationship. The purpose of this investigation was to examine the initial reaction of maxillofacial complex to the maxillary protraction by using extraoral orthopedic force. The dried human skull was used and this investigation was done by means of double exposure holographic interferometry. The protraction forces placed on the canine or the first molar were parallel, $10^{\circ}$ downward, $20^{\circ}$ downward to the occlusal plane. Fringe pattern of each protraction condition was compared and analized. The results were as follows: 1. Each maxillofacial bone displaced saparately. 2. More displacement was shown at the area of the teeth and the alveolar bone. 3. A counterclockwise rotation of the maxilla wa decreased by downward protraction and especially 20 degree downward protraction from the canine showed least rotation. 4. On the zygomatic arch, outward bend was observed and this effect was decreased by downward protraction. 5. On the zygomatic bone, the counter clockwise rotation was increased by the downward protraction. 6. When maxillary expansion was applied at the same time, outward and upward displacement with counterclockwise rotation was observed on the maxilla. 7. The lateral pterygoid plate of sphenoid bone was affected by maxillary protraction.

  • PDF