Browse > Article
http://dx.doi.org/10.7742/jksr.2014.8.6.333

The Study on Design of Customized Radiation Protective Layer for Medical Radiation Dose Reduction  

Kang, Sang-Sik (Dept. of Radiological Science, International University of Korea)
Kim, Kyo-Tae (Dept. of Hybrid Medicine and Science, Inje University)
Noh, Si-Cheol (Dept. of Radiological Science, International University of Korea)
Jung, Bong-Jae (Dept. of Radiological Science, International University of Korea)
Park, Ji-Koon (Dept. of Radiological Science, International University of Korea)
Publication Information
Journal of the Korean Society of Radiology / v.8, no.6, 2014 , pp. 333-338 More about this Journal
Abstract
The fact is that in addition to an increase in social needs that must be managed systematically unnecessary exposure in the field of medical Recent important that the shield has emerged. However, products that are now in practical use, are not subdivided as compared to various medical radiology. Therefore, in the present study, we tried to present with the help of Monte Carlo simulation the structure of the shielding material that has been optimized. Simulated estimation result, the energy of the mammography for (30 kVp) spectrum, check the shielding rate of 90% or more $30{\mu}mPb$, at 2 mmAl case of shielding material of a single, at design time of 1 mmAl and 0.03 mmPb a double shield structure it is determined that more efficient. Also, check the blocking rate of 90% or more $340{\mu}mPb$, at 30 mmAl energy captured general in (80 kVp) spectra, it is considered that a double shield structure, design 1 mmAl and 0.3 mmPb is useful. These results, be used as basic material for the development of commercialization customized products for dose reduction is expected.
Keywords
Monte Carlo Simulation; Double-shielded structure; Lead; Aluminium; Shielding rate;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Kyo-Tae Kim, Ye-Ji Heo, Jung-Wook Shin, et al, "A Study on the Improvement of Evaluation Methods and Standards for Simulation evaluation of Computed Tomography", The Korean Society of Radiology, Vol 7, No 5, pp. 339-345, 2013   과학기술학회마을   DOI   ScienceOn
2 Ye-Ji Heo, Kyo-Tae Kim, Si-Cheul Noh, et al, "A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment", The Korean Society of Radiology, Vol 8, No 3, pp. 105-110, 2014   과학기술학회마을   DOI   ScienceOn
3 IAEA Safety Series No.115 : "International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources", Vienna, 1996
4 ICRP Publication 103: Recommendations of the Inter-national Commission on Radiological Protection, Oxford, 2007
5 "Patient Dose Reference Levels Guidelines of General Radiology", Korea Food & Drug Administration, Radiation safety management series, No. 30, 2012
6 Hyung-Soo Kim, Seung-Youl Lee, Jung-Eun Lee, et al, "Study for the appropriate management of the diagnostic radiological devices", radiation safety division, 2013
7 Kyo-Tae Kim, Sang-Sik Kang, Si-Cheul Noh, et al, "Absorbed Spectrum Comparison of Lead and Tungsten in Continuous X-ray Energy using Monte Carlo Simulation", The Korean Society of Radiology, Vol 6, No 6, pp. 483-487, 2012   과학기술학회마을   DOI   ScienceOn
8 Pyong-Kon Cho, Joon-Hyup Lee, Yoon-Sik Kim, et al, "A Study on measurement of scattery ray of Computed Tomography", Korean Society of Radiological Science, Vol 26, No 3, pp. 37-42, 2003   과학기술학회마을
9 Seon-Chil Kim, Kyo-Tae Kim, Ji-Koon Park, "Barkum compounds through Monte Carlo simulation compare the performance of medical radiation shielding analysis", The Korean Society of Radiology, Vol 7, No 6, pp. 403-408, 2013   DOI   ScienceOn
10 Judith.F. Briesmeister, "MCNPTM A General Monte Carlo N-Particle Transsport Code. Ver. 4C", 2000.
11 Chan-Wook Kim, "A Study for Partial Dose to Evaluate the Exposure Dose of Major Organ in Mammography", The Graduate School International University of Korea, 2013