• 제목/요약/키워드: dose response

검색결과 2,332건 처리시간 0.032초

The role of salvage radiotherapy in recurrent thymoma

  • Yang, Andrew Jihoon;Choi, Seo Hee;Byun, Hwa Kyung;Kim, Hyun Ju;Lee, Chang Geol;Cho, Jaeho
    • Radiation Oncology Journal
    • /
    • 제37권3호
    • /
    • pp.193-200
    • /
    • 2019
  • Purpose: To explore the role of salvage radiotherapy (RT) for recurrent thymoma as an alternative to surgery. Materials and Methods: Between 2007 and 2015, 47 patients who received salvage RT for recurrent thymoma at Yonsei Cancer Center were included in this study. Recurrent sites included initial tumor bed (n = 4), pleura (n = 19), lung parenchyma (n = 10), distant (n = 9), and multiple regions (n = 5). Three-dimensional conformal and intensity-modulated RT were used in 29 and 18 patients, respectively. Median prescribed dose to gross tumor was 52 Gy (range, 30 to 70 Gy), with equivalent doses in 2-Gy fractions (EQD2). We investigated overall survival (OS), progression-free survival (PFS), and patterns of failure. Local failure after salvage RT was defined as recurrence at the target volume receiving >50% of the prescription dose. Results: Median follow-up time was 83 months (range, 8 to 299 months). Five-year OS and PFS were 70% and 22%, respectively. The overall response rate was 97.9%; complete response, 34%; partial response, 44.7%; and stable disease, 19.1%. In multivariate analysis, histologic type and salvage RT dose (≥52 Gy, EQD2) were significantly associated with OS. The high dose group (≥52 Gy, EQD2) had significantly better outcomes than the low dose group (5-year OS: 80% vs. 59%, p = 0.046; 5-year PFS: 30% vs. 14%, p=0.002). Treatment failure occurred in 34 patients; out-of-field failure was dominant (intra-thoracic recurrence 35.3%; extrathoracic recurrence 11.8%), while local failure rate was 5.8%. Conclusion: Salvage RT for recurrent thymoma using high doses and advanced precision techniques produced favorable outcomes, providing evidence that recurrent thymoma is radiosensitive.

흰쥐의 술 후 통증 모델에서 T형 칼슘 통로 차단제인 Ethosuximide와 Mibefradil의 항통각과민 효과 (Antihyperalgesic Effects of Ethosuximide and Mibefradil, T-type Voltage Activated Calcium Channel Blockers, in a Rat Model of Postoperative Pain)

  • 신혜란;차영덕;한정욱;윤정원;김부성;송장호
    • The Korean Journal of Pain
    • /
    • 제20권2호
    • /
    • pp.92-99
    • /
    • 2007
  • Background: A correlation between a T-type voltage activated calcium channel (VACC) and pain mechanism has not yet been established. The purpose of this study is to find out the effect of ethosuximide and mibefradil, representative selective T-type VACC blockers on postoperative pain using an incisional pain model of rats. Methods: After performing a plantar incision, rats were stabilized on plastic mesh for 2 hours. Then, the rats were injected with ethosuximide or mibefradil, intraperitoneally and intrathecally. The level of withdrawal threshold to the von Frey filament near the incision site was determined and the dose response curves were obtained. Results: After an intraperitoneal ethosuximide or mibefradil injection, the dose-response curve showed a dose-dependent increase of the threshold in a withdrawal reaction. After an intrathecal injection of ethosuximide, the threshold of a withdrawal reaction to mechanical stimulation increased and the increase was dose-dependent. After an intrathecal injection of mibefradil, no change occurred in either the threshold of a withdrawal reaction to mechanical stimulation or a dose-response curve. Conclusions: The T-type VACC blockers in a rat model of postoperative pain showed the antihyperalgesic effect. This effect might be due to blockade of T-type VACC, which was distributed in the peripheral nociceptors or at the supraspinal level. Further studies of the effect of T-type VACC on a pain transmission mechanism at the spinal cord level would be needed.

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.

Estimation of Relative Potency with the Parallel-Line Model

  • Lee, Tae-Won
    • 응용통계연구
    • /
    • 제25권4호
    • /
    • pp.633-640
    • /
    • 2012
  • Biological methods are described for the assay of certain substances and preparations whose potency cannot be adequately assured by chemical or physical analysis. The principle applied through these assays is of a comparison with a standard preparation to determine how much of the examined substance produces the same biological effects as a given quantity (the Unit) of the standard preparation. In these dilution assays, to estimate the relative potencies of the unknown preparations to the standard preparations, it is necessary to compare dose-response relationships of standard and unknown preparations. The dose-response relationship in the dilution assay is non-linear and sigmoid when a wide range of doses is applied. The parallel line model (applied to the dose region with the steepest slope) is used to estimate the relative potency. In this paper, the statistical theory in the parallel line model is explained with an application to a dilution assay data. The parallel line method is implemented in a SAS program and is available at the author's homepage(http://cafe.daum.net/go.analysis).

Pharmacokinetic-Pharmacodynamic Modeling of a Direct Thrombin Inhibitor, Argatroban, in Rats

  • Park, Eun-Hye;Shin, Beom-Soo;Yun, Chi-Ho;Lee, Mann-Hyung;Yoo, Sun-Dong
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권5호
    • /
    • pp.373-379
    • /
    • 2009
  • This study was conducted to develop a pharmacokinetic-pharmacodynamic (PK/PD) model of a direct thrombin inhibitor, argatroban to predict the concentration-effect profiles in rats. Argatroban was i.v. injected to rats at 0. 2, 0.8 and 3.2 mg/kg doses (n = 4-5 per dose), and plasma drug levels were determined by a validated LC/MS/MS assay. The pharmacokinetics of argatroban was linear over the i.v. dose range studied. The thrombin time (TT) and the activated partial thromboplastin time (aPTT) were measured in rat plasma and they were found to linearly increase with increasing the dose. A 2-compartment pharmacokinetic model linked with an indirect response pharmacodynamic model was successfully utilized to evaluate the drug concentration-response relationship.

Retrospective dosimetry using fingernail electron paramagnetic resonance response

  • Noori, Abbas;Mostajaboddavati, Mojtaba;Ziaie, Farhood
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.526-530
    • /
    • 2018
  • Human fingernails were used to estimate the radiation dose via electron paramagnetic resonance measurements of radiation-induced radicals. The limiting factors in this research were mechanically induced electron paramagnetic resonance signals due to the mechanical stress during the preparation of the samples. Therefore, different treatment methods of fingernails were used to reduce the mechanically induced signals. The results demonstrate that the mechanically induced and radiation-induced signals have apparently different microwave power saturation behaviors. In addition, the mechanically induced signal shows a fading evolution over time and reaches a constant value. Chemical treatment using the different reagents showed that the minimum mechanically induced signal was obtained using the dithiothreitol reagent. The dose-response curves of the samples treated with dithiothreitol for 30 minutes demonstrated a greater linearity than those of samples treated for 5 minutes. Therefore, to find an unknown absorbed dose in a fingernail sample using a calibration curve, we recommend adopting the mentioned chemical treatment procedure to reduce the uncertainty.

한인전 추출물의 간장보호 작용에 관한 연구 (A Study on the Hepatoprotective effect of PS-1 from Artemisia iwayomogi)

  • 이순복;조태순;윤기욱;이종찬;이선미;심성보
    • Biomolecules & Therapeutics
    • /
    • 제6권2호
    • /
    • pp.119-129
    • /
    • 1998
  • The dose-response effect of polysaccharide extracts(PS-1) from Artemisia iwayomogi was inves-tigated under various hepatic disease models. Silymarin, DDB and UDCA were used as reference compounds. We found that the maximal effective dose of PS-1 was 100 mg/kg b.wt. in $CCl_4$-induced hepatotoxicity, D-galactosamine-induced hepatitis, in ANIT-induced cholestasis and 300 mg/kg b.wt. in $CCl_4$-induced chronic liver disease, 30 mg/tg b.wt. in chronic bile duct ligation and chronic ethanol fatty liver. These findings suggest that PS-1 fraction protects the hepatocyte against various hepatic injuries, and this fracton might be of therapeutic value.

  • PDF

Effect of Low Dose Mutagens on Adoptive Response and Plasma Membrane Glycoconjugates in Sarcoma 180 Cells

  • Lee, Jong Hwa;Choi, Eun Sili;Oh, Kyu Seon;Lee, Dong Wook;Chang, Jeong Hyun;Um, Kyung Il
    • Animal cells and systems
    • /
    • 제4권3호
    • /
    • pp.293-297
    • /
    • 2000
  • The present investigation was performed to elucidate the effect of pretreatment with low dose ultraviolet radiation (UV) and ethyl methanesulfonate (EMS) on cell survival by trypan blue dye exclusion method and plasma membrane glycoconjugates by lectin-cytochemistry in sarcoma 180 (S180) cells. Pretreatment with 2 J/$m^2$ UV or 2 mM EMS increased the percentage of survival of cells subsequently treated with high dose UV (10 or 20 J/$m^2$) or EMS (10 or 20 mM), respectively. Staining intensity of concanavalin A (Con A) of the cells pretreated with 2J/$m^2$ UV or 2 mM EMS and subsequently treated with 10 or 20 mM EMS was stronger than that of the cellstreated with 10 or 20 mM EMS. These results suggest that there is an adaptive response on cell survival to EMS or UV in S180 cells. And the results show a change in mannose-containing glycoconjugates of plasma membrane in S180 cells pretreated with EMS or UV and subsequently treated with EMS.

  • PDF

Novel biological strategies to enhance the radiation therapeutic ratio

  • Kim, Jae Ho;Jenrow, Kenneth A.;Brown, Stephen L.
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.172-181
    • /
    • 2018
  • Successful anticancer strategies require a differential response between tumor and normal tissue (i.e., a therapeutic ratio). In fact, improving the effectiveness of a cancer therapeutic is of no clinical value in the absence of a significant increase in the differential response between tumor and normal tissue. Although radiation dose escalation with the use of intensity modulated radiation therapy has permitted the maximum tolerable dose for most locally advanced cancers, improvements in tumor control without damaging normal adjacent tissues are needed. As a means of increasing the therapeutic ratio, several new approaches are under development. Drugs targeting signal transduction pathways in cancer progression and more recently, immunotherapeutics targeting specific immune cell subsets have entered the clinic with promising early results. Radiobiological research is underway to address pressing questions as to the dose per fraction, irradiated tumor volume and time sequence of the drug administration. To exploit these exciting novel strategies, a better understanding is needed of the cellular and molecular pathways responsible for both cancer and normal tissue and organ response, including the role of radiation-induced accelerated senescence. This review will highlight the current understanding of promising biologically targeted therapies to enhance the radiation therapeutic ratio.

광자극선량계의 저에너지 엑스선 특성비교 (Measuring Absorbed Dose from Medical X-ray Equipment Using Optically Stimulated Luminescence Dots)

  • 정숙진;진계환
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.79-83
    • /
    • 2018
  • 본 논문에서는 OSL 도트 선량계의 교정인자, 흡수선량 선형성, 피크전압 선형성, 각도 변화에 의한 흡수선량 변화를 측정하고 분석했다. 의료용 X 선발생 장치를 사용하여 조사에 노출 선량 보정 계수, 흡수선량 선형성, 피크 전압 선형성은 모두 IEC-62387-1 (2007) 기준을 만족하였다. 기준 방사선 노출과 관련하여 0도, 30도 및 60도에서 선량계 방향에 대한 기준은 -29 % (${\pm}30^{\circ}$) 및 + 67 % (${\pm}60^{\circ}$)이었다. 30도에서 측정된 값은 기준보다 -8 % 낮고 60도에서 기준보다 -18 % 낮게 나타났다. 그러므로 OSL 도트 선량계 사용 시 방향에 따른 영향을 보정하여야 한다.