• 제목/요약/키워드: dose limit

검색결과 410건 처리시간 0.036초

매실농축액의 에틸카바메이트 분석과 노출량 평가 (Determination of Ethyl Carbamate in Maesil Extract and Estimated Daily Intake)

  • 최보경;고은미
    • 한국식품조리과학회지
    • /
    • 제31권2호
    • /
    • pp.112-117
    • /
    • 2015
  • The analytical method for ethyl carbamate (EC) in maesil (Prunus mume) extract was developed with deuterium-labeled ethyl carbamate as an internal standard. Samples were neutralized with an addition of 1 N sodium hydroxide solution, followed by a solid phase extraction with a Chem Elut cartridge. A standard curve exhibited a good linearity with correlation coefficient of 0.9991. The limit of detection (LOD) and limit of quantification (LOQ) were 2.91 ng/g and 8.83 ng/g, respectively. The recovery rate of EC ranged from 91.40% to 120.90%. The precision never exceeded 12.57% (intra-day) and 11.03% (inter-day). Samples were comprised of 24 home-made and 7 commercially-available maesil extracts. Eight home-made samples contained EC at levels between 3.39 and 75.76 ng/g. Three commercially-available samples had EC at levels between 11.67 and 20.16 ng/g. Average daily intakes of EC from maesil extracts for consumers were 0.23 g/kg of body weight. Based on a benchmark dose confidence limit ($BMDL_{10}$) of 0.25 mg/kg of body weight/day, the margin of exposure (MOE) of EC in maesil extract for consumers was 94,150, which is not of concern. Considering that a daily intake of maesil extract has been increasing, further studies on the formation of EC in maesil extract is needed.

고리 1호기의 기사용 핵연료 집합체 수송용기 설계에 관한 연구 (Design Study of A Spent Fuel Shipping Cask for Korea Nuclear Unit-1)

  • Moo Han Kim;Chang Sun Kang
    • Nuclear Engineering and Technology
    • /
    • 제14권4호
    • /
    • pp.196-203
    • /
    • 1982
  • 본 논문에서는 고리 1호기의 기사용 핵연료 집합체를 수송하기 위한 Cask를 설계하였다. 이를 위하여 고리 1호기의 기사용 핵연료 집합체로부터 방출되는 감마선과 중성자를 계산하여 MORSE 및 ANISN전산 코드로써 차폐 계산을 수행하였다. 그 결과, 9개의 집합체를 동시에 수송할 수 있는 Steel Cask가 가장 적합하다는 것을 밝혔다. 이 Steel Cask에 대한 안전성을 평가하기 위하여 연료봉의 중심 온도와 복재온도를 계산하여 핵연료의 용융점보다 훨씬 낮음을 증명하였다. 또한 KENO와 MORSE전산 코드를 사용하여 임계도 계산을 수행하여 미임계 상태임을 증명하였다. 이로써 9개의 기사용 핵연료 집합체를 동시에 수송할 수 있는 Steel Cask를 간단히 설계하였다.

  • PDF

나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가 (Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy)

  • 박수연;채문기;임준택;권동열;김학준;정은아;김종식
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.93-109
    • /
    • 2020
  • 목 적: 나선형 토모테라피 방사선치료를 위한 환자별 품질관리용 라디오크로믹 필름 및 3차원 분석시스템인 Dosimetry CheckTM (DC, MathResolutions, USA)의 성능평가를 시행하였다. 대상 및 방법: 인체모형팬톰(Anderson Rando Phantom, USA)을 이용하여 위치 변이가 있는 3가지 형태의 복부 종양(130.6㎤), 복막 후면 종양(849.0㎤) 및 전 복부 전이 종양(3131.0㎤)을 모델링하였다. 조사면 고정너비(field width, FW)를 2.5-cm, 5.0-cm, 피치(pitch) 0.287, 0.43으로 하여 부위별 4개씩(plan01-plan04), 총 12개의 비교용 치료계획을 수립하였다. 이온전리함(1D)과 라디오크로믹 필름(Gafchromic EBT3, Ashland Advanced Materials, USA)을 치즈팬톰 내 삽입하는 방법(2D)과 빔 플루언스 로그정보를 이용하여 CT영상 위에 선량을 3차원으로 재구성하는 방식의 DC측정을 진행하였다. 스레드효과(thread effect)를 분석을 위해 리플(ripple) 진폭(%)를 계산하였고, 선량 분포의 패턴 분석을 위해 감마인덱스 분석(DD: 3%/DTA: 3mm, 합격 문턱 값: 95%)을 수행하였다. 결 과: 리플 진폭 측정 결과 복막 후면 종양이 평균 23.1%로 가장 높았다. 라디오크로믹 필름의 분석결과, 절대 선량 평균 1.0±0.9%, 감마인덱스분석 평균 96.4±2.2%로 95% 이상 통과하였으나 전 복부 전이 종양과 같이 넓은 부위 평가에 범위의 제한적이었다. 인체모형팬톰에 적용한 DC 분석결과 FW가 5.0-cm인 세 부위의 2D 및 3D 플랜 평균이 91.8±6.4%였다. 세 단면 및 선량 프로파일 분석을 통해 복막 후면 및 전 복부 종양 표적 전체 영역에 분석이 가능하였고, 선량-용적 히스토그램을 통한 계획 선량 대 측정의 선량 오차가 FW 및 pitch에 따라 커지는 것을 확인하였다. 결 론: DC측정방법은 별도의 측정기 없이 조사 중 측정된 빔 플루언스 로그정보만으로 3차원 환자 영상 데이터 위에 선량 오류를 구현할 수 있고 종양의 위치나 크기에 제한이 없어 크고 불규칙한 종양의 나선형 토모테라피의 치료 시 환자별 품질관리 성능이 매우 우수하며 활용도가 높을 것으로 생각한다.

Ho-166-CHICO 치료 후 평면 영상을 이용한 방사선 흡수선량의 계산 (Radiation Absorbed Dose Calculation Using Planar Images after Ho-166-CHICO Therapy)

  • 조철우;박찬희;원재환;왕희정;김영미;박경배;이병기
    • 한국의학물리학회지:의학물리
    • /
    • 제9권3호
    • /
    • pp.155-162
    • /
    • 1998
  • 방사성 동위원소의 치료에 베타 방출 선원이 많이 이용되고 있다. 베타 방출 핵종 들은 투과력이 약해 방사선 도달거리 (range)가 짧아 병소내에 직접 주입하여 선택적으로 병소만을 조사하여 치료 의 효과를 얻을 수 있고 주변 정상 조직의 방사선 피폭을 줄일 수 있다. 최근 한국 원자력연구소의 원자로인 하나로를 이용하여 베타 입자 방출체인 Ho-l66 용액을 만들어 여기에 키토산 화합물을 표지 하였다. Ho-l66 은 고 에너지 베타 방출체라는 점과 일부 감마선이 방출됨으로써 감마카메라로 쉽게 영상을 얻을 수 있다는 장점이 있다. 본 연구에서는 감마카메라로 얻은 평면 영상을 이용하여 Ho-l66으로 치료한 부위와 그 주변의 정상 장기들의 방사선 홉수선량을 구하였다. 감마카메라는 Siemens 의 2중 head를 가진 Multispect2 시스템이 이용되었고, 콜리메이터는 medium energy, 최대 에너지는 80 keV, 창은 20%로 5분간 영상을 획득하였다. Ho-166 에 대한 투과인자 (transmission factor)는 환자 있을 때와 없을 때의 영상으로 관심영역의 ROIs 의 비로 구하였다 .3일간의 평면 영상으로 유효반감기를 구하여 Marinelli 공식과 MIRD 공식으로 베타입자에 대한 방사선 흡수선량을 구하였다. 감마선에 의한 흡수선량은 매우 적으므로 무시하였다. Transmission factor는 환자에 따라 다르지만 1110 MBq(30 mCi)을 주입하여 치료에 임한 간암 환자의 경우 간은 4.6, 비장은 4.65, 폐는 3.34, 뼈는 5.65 의 값을 보였다. 방사선 홉수선량은 tumor 에는 179.7, 정상간에는 16.3, 비장은 18.5, 폐에는 7.0, 뼈에는 9.0 Gy 가 각각 계산되었다. 이를 tumor dose 에 100%로 normalization 시킬 경우 정상간, 비장, 폐, 뼈에 각각 9.1, 10.3, 3.9, 5.0%로 분포되었음을 알았다. 본 연구를 통하여 tumor dose 뿐만이 아니고 주변 주요 위험장기 (critical organ) 에 대한 방사선 흡수선량을 전ㆍ후면 평면영상으로 얻을 수 있음을 보여 줌으로써 평면영상법을 이용한 dosimetry 의 가능성을 보았다. 또한 주변 주요 위험 장기의 한계선량에 맞는 주입할 양을 결정하는데 기초 자료가 될 수 있음을 보여준다.

  • PDF

인삼 중 Clothianidin 및 Thiacloprid의 생산단계 농약잔류허용기준 설정 (Establishment of Pre-Harvest Residue Limits of Clothianidin and Thiacloprid in Ginseng)

  • 나은식;이용재;김경주;김성수;이규승
    • 농약과학회지
    • /
    • 제17권3호
    • /
    • pp.155-161
    • /
    • 2013
  • 본 연구는 인삼 재배 중 사용되는 clothianidin과 thiacloprid의 생산단계 잔류허용기준 설정을 통하여 안전한 인삼 생산에 기여하고자 수행되었다. 먼저, clothianidin과 thiacloprid을 살포하고, 살포 후 0, 2, 5, 8, 12, 16, 20, 24, 28, 33, 42일의 총 11회에 걸쳐 인삼 시료를 채취하여 각각의 농약을 분석하고 생물학적 반감기를 산출한 다음 생산단계 잔류허용기준(PHRL)을 설정하였다. 인삼 중 clothianidin과 thiacloprid은 acetonitrile을 이용하여 추출하여 UPLC/TQD로 분석하였다. 두 농약에서 검출한계는 모두 0.01 mg/kg이었다. Clothianidin의 회수율은 0.2 mg/kg 과 1.0 mg/kg 두 수준에서 각각 $108.6{\pm}5.4%$, $100.4{\pm}1.1%$이었으며, thiacloprid의 회수율은 0.5 mg/kg과 2.5 mg/kg 수준에서 각각 $93.4{\pm}4.9%$, $91.1{\pm}6.2%$이었다. 인삼에서 clothianidin의 생물학적 반감기는 기준량 살포 시 14.6일, 배량 살포시 10.2일 이었고, thiacloprid의 생물학적 반감기는 기준량 살포 시 9.7일, 배량 살포시 11.2일이었다. 잔류회귀 감소식을 이용한 생산단계 잔류허용기준은 clothianidin과 thiacloprid은 각각 수확 10일 전 0.30 mg/kg과 0.18 mg/kg으로 제안하였다.

진단방사선촬영에서 광자극발광선량계를 이용한 환자 피부선량의 측정 (Measurement of the Skin Dose of Patient Using the Optically Stimulated Luminescent Dosimeter at Diagnostic Radiography)

  • 김종언;임인철;민병인
    • 한국콘텐츠학회논문지
    • /
    • 제11권9호
    • /
    • pp.437-442
    • /
    • 2011
  • 본 연구의 목적은 진단방사선촬영의 X-선 빔 조사 조건하에서 광자극발광선량계를 사용하여 환자의 피부선량을 측정하는 것이다. 피부선량의 측정은 머리, 가슴, 골반에 대하여 실시하고 재현성의 시험은 가슴에서 시행하였다. 그 결과 머리는 이마에서 피부선량 1.30 mSv의 값을 얻었으며 가슴은 검상돌기, 유방, 폐첨에서 각각 0.92, 0.52, 0.70 mSv의 값을 얻었다. 또한 골반은 좌측골반과 우측골반에서 피부선량 각각 2.78, 3.08 mSv의 값을 얻었다. 재현성은 변동계수로서 0.033을 얻었다. 피부선량들은 결정적 영향에서 일반인의 선량한도(50 mSv)의 1/100에서 1/17에 대응하는 값들을 나타냈다. 각 관전압에 대한 피부선량의 정확한 측정을 위하여 측정값은 판독장치의 표시값에 보정인자를 곱해야 한다. 이에 향후에는 관전압에 대한 에너지의존성의 연구가 진행되어야 할 것으로 사료된다.

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

개에서 진드기 살충제 amitraz의 단회피하투여 독성시험 (A Single Subcutaneous Dose Toxicity Study of The Acaricide Amitraz in Beagle Dogs.)

  • 허정두;김영길;이현숙;김충용;박승춘;신진영;김성호;신동호;김종춘
    • 생명과학회지
    • /
    • 제14권4호
    • /
    • pp.547-552
    • /
    • 2004
  • 본 연구는 살충제 amitraz의 피하투여 급성독성을 평가하기 위해 0, 2, 10 및 50 mg/kg용량으로 1회 피하투여한 후, 사망률과 일반증상, 체중, 혈액 및 혈청생화학 및 부검소견에 미치는 영향을 평가하였다. 시험결과, 비글 개에 있어서 amitraz의 단회 피하투여는 식욕부진과 침울, 구토, 유루, 운동성감소, 보행실조, 투여부위의 부종, 종괴 및 농양형성, 사지의 부전마비, 횡와위, 빈사, 사망, 체중감소, 투여부위의 근육출혈과 염증, 그리고 간과 신장의 충혈을 유발하는 것으로 나타났다. 반면, 투여 후 14일째에 생존동물의 혈액 및 혈청생화학치에서는 시험물질의 투여와 관련된 어떠한 변화도 인정되지 않았다. 결론적으로 본 시험조건하에서 비글 개에 대한 amitraz의 반수치사량은 22.3 mg/kg (95% 신뢰 한계: 산출되지 않음)이고, 무해용량(no-observed-adverse-effect level)은 2 mg/kg 이하로 사료된다.

디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가 (Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination)

  • 김성민;홍선숙;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

CARI-6를 이용한 국제선 노선별 선량 및 항공승무원의 피폭선량 평가 (Calculation of Route Doses for Korean-based International Airline Routes using CARI-6 and Estimation of Aircrew Exposure)

  • 홍종호;권정완;정제호;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제29권2호
    • /
    • pp.141-150
    • /
    • 2004
  • 특정 비행노선에서 우주선에 의한 누적선량을 계산하는 프로그램인 CARI-6를 이용하여 비행고도 우주선 방사선장의 선량률 변화 특성을 분석하고, 국적항공사에서 운행하는 전 국제선 노선에 대한 노선별 우주선 피폭선량을 산출하였다. 산출한 노선별 선량을 항공승무원의 비행스케쥴과 국민의 항공여행 통계에 적용하여 우리나라 항공승무원과 일반 여행객의 우주선에 의한 연간 피폭선량과 집단유효선량을 평가하였다. 평가 결과, 항공승무원의 피폭이 일반인의 선량한도인 연간 1 mSv를 초과하여 평균 2.62mSv로 다른 직업상 피폭을 받는 직군의 선량과 대등한 것으로 평가되었다. 따라서 항공승무원 적군의 우주선 피폭을 일종의 직업상 피폭으로 간주함이 타당함을 확인하였다. 나아가 국민의 해외여행으로 인한 집단선량은 2001년 기준으로 1,100만 명의 출입국자가 총 136man-Sv를 피폭한 것으로 나타났다. ICRP 92에서 양성자와 중성자의 방사선가중치를 변경한 결과를 반영하여 비행고도에서의 우주선 방사선장 정보가 수정될 경우 위의 평가 결과는 보완되어야 한다.