Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가 (Evaluation of the Utility of a Volumetric Modulated Arc Therapy Specific Patient Quality Assurance using Software-based Quality Assurance System)

  • 강동진;정재용;신영주;민정환;김연래;권경태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.39-45
    • /
    • 2018
  • The purpose of this study is to evaluate the usefulness of a software-based quality assurance system based on Volumetric Modulated Arc Therapy treatment plan. Evaluate treatment plan through the D VH analysis, PTV mean dose ($D_{mean}$) and PTV 95% dose($D_{95}$) compare the MFX based on original treatment plan, Average error rate was $0.9{\pm}0.6%$, $1.0{\pm}0.8%$, respectively. Measuring point dose using phantom and ion chamber, the average error rate between the ionization chamber and MFX was $0.9{\pm}0.7%$, $1.1{\pm}0.7%$ (high dose region), $1.1{\pm}0.9%$, $1.2{\pm}0.7%$ (low dose region). The average gamma though of MFX and $Delta^{4PT}$ is $98.7{\pm}1.2%$, $98.4{\pm}.3%$, respectively. Through this study, A software based QA system that simplifies hardware based QA procedures that involve a lot of time and effort. It can be used as a simple and useful tool in clinical practice.

M&S 기반 반도체소자의 펄스감마선 피해평가 시스템 구축 연구 (A Study on Implementation of a Transient Radiation Effects on Electronics(TREE) Assessment System Based on M&S)

  • 이남호;이승민
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.969-973
    • /
    • 2013
  • To simulate the effect of high dose-rate radiation on semiconductor devices, device modeling work has been performed especially in the area of photo-current generation by a PIN diode. The resultant analytical values were compared with experimental ones that were specially designed and performed to benchmark the simulation results. Initial results showed 27.85% error between the simulation and the experiment. The error can be further reduced by improvement both in simulation and in related experiments. The developed technique from the study can be applicable to radiation dosimetry and to analysis on the radiation effects in electronics.

엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성 (Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray)

  • 권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권5호
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구 (Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR))

  • 황준호;최지안;이경배
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.375-383
    • /
    • 2020
  • 본 연구는 자동노출제어장치 사용 시 이온 챔버의 성능과 조합에서 비롯된 문제를 정량적으로 분석하는 방법론을 제시하고 디지털 방사선 시스템의 성능을 최적화하고자 하였다. 실험방법은 복부와 골반부 검사에 사용된 파라미터의 X선질을 백분율 평균오차(PAE; Percentage Average Error)와 반가층(HVL; Half Value Layer)으로 평가하였다. 그 후 세 가지 이온 챔버를 조합했을 때의 입사표면선량(ESD; Entrance Surface Dose)과 엔트로피(Entropy)를 산출하여 방사선 출력의 안정성과 영상 품질을 분석하였다. 그 결과 실험에 사용한 디지털 방사선 시스템의 X선질은 모두 정상 범위의 백분율 평균오차와 반가층을 보였다. 입사표면선량은 챔버의 조합에 비례하여 증가하였고, 엔트로피는 세 개의 챔버가 조합됐을 때를 제외하고는 이온 챔버의 조합에 비례하여 증가하였다. 결론적으로 입사표면선량과 엔트로피를 이용한 분석은 이온 챔버의 성능과 조합의 문제를 평가하는데 유용한 방법인 것을 알 수 있었으며, 두 개 이하의 이온 챔버를 조합했을 때 디지털 방사선 시스템의 성능을 최적으로 유지할 수 있음을 알 수 있었다.

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF

Co-60 Teletherapy Unit를 이용한 전신조사의 선량분포에 관한 고찰 (A Study on the Dose Distribution for Total Body Irradiation using Co-60 Teletherapy Unit)

  • 김성규;심세원;김명세
    • Journal of Yeungnam Medical Science
    • /
    • 제6권2호
    • /
    • pp.113-119
    • /
    • 1989
  • 본 교실에서 Co-60치료기를 이용한 전신조사에 대한 선량의 측정 및 분석 결과는 다음과 같았다. 1. 폐부위는 기준되는 복부(24cm)에 비해 두께는 두껍지만(25.6cm) 폐의 낮은 밀도 때문에 6% 정도 더 많은 선량이 측정되어 폐손상이나 폐동맥 합병증의 예방을 위하여 적절한 보상판이 필요함을 시사하였다. 2. inverse square law에 의한 이론치 보다 실제의 측정치는 3% 정도 적게 측정되었다. 3. 머리부위(두께 15.8cm)와 목부위(11.0cm)는 얇은 두께 때문에 10%, 18% 정도 더 많은 선량이 측정되었고, 골반부위(두께 36.0cm)는 12% 정도 더 적은 선량이 측정되어 전신조사시 모든 부위에 등선량을 조사하기 위해서는 적당한 보상판이 필수적임을 시사하였다.

  • PDF

국제기준을 적응한 치료계획시스템 정확성 평가 (Estimation of RTP Accuracy Based the International Reference Level)

  • 오영기;김기환;정동혁;최태진;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제19권2호
    • /
    • pp.113-119
    • /
    • 2008
  • 본 연구에서는 6종에 대한 RTP의 실험 결과에 대하여 오차를 평가하고 AAPM Report-62의 평가 항목에 적용하여 RTP 오차의 허용범위 여부를 조사하였다. 이를 위하여 NDR (Normalized dose rate) 개념을 도입하여 RTP 계산값과 측정값을 동일한 기준으로 비교할 수 있도록 하였다. 평가결과 대부분의 RTP들은 차폐조사면과 불균질 물질의 계산에서 허용범위 이내의 오차를 보였으나 표면 불균일성에 대해서는 대부분 허용범위를 초과하는 것으로 나타났다.

  • PDF

선속 폭(Field Width) 변화에 따른 종축선량 분석 (Analysis on Longitudinal Dose according to Change of Field Width)

  • 정원석;백종걸;신령미;오병천;조준영;김기철;최태규
    • 대한방사선치료학회지
    • /
    • 제23권2호
    • /
    • pp.109-117
    • /
    • 2011
  • 목 적: 호흡에 의하여 영향을 받는 장기의 토모 치료 시 선속 폭(Field Width) 변화에 따른 종양 용적선량의 선량 전달 정확성을 분석하고 자체 제작한 Moving car를 사용하여 선량 변화의 차이를 확인하고 실질적인 종양 선량의 전달 선량을 평가해 보고자 한다. 대상 및 방법: 자체 제작한 Moving car를 사용하여 종축 움직임 차이(0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm)를 적용하고 선속 폭(Field Width) 변화(1.05 cm, 2.50 cm, 5.02 cm)에 따른 측정된 선량의 값을 계산된 선량 값과 비교하여 오차범위를 파악하였다. Gafchromic EBT 필름을 이용하여 측정한 DQA (Delivery Quality Assurance) 필름의 감광정도를 선량윤곽(Dose Profile)과 Gamma Histogram을 이용하여 비교 분석하였다. 결 과: 선속 폭(Field Width) 1.05 cm, 2.50 cm, 5.02 cm일 때 오차범위가 각각 -2.00%, -0.39%, -2.55%의 선량 전달율을 나타내었다. Gafchromic EBT 필름 분석의 선량 윤곽(Dose profile)에서는 Moving car의 움직임이 있는 상태에서 종축방향으로의 움직임이 클수록, 선속 폭(Field Width)이 좁아질수록 고선량 부분에서 계산된 선량과의 오차가 크게 나타났다. Gamma histogram에서는 gamma index가 선속 폭(Field Width)이 좁을수록 움직임의 영향이 상당히 증가하는 것을 알 수 있었다. 결 론: 자체 제작한 Moving car를 이용하여 움직이는 장기의 종축선량 차이를 확인할 수 있었으며 토모 치료 시 선속 폭(Field Width)을 작게 하고 호흡에 의한 장기의 움직임을 최소화하기 위하여 호흡조절 장치와 고정기구의 개발이 필요하리라 사료된다.

  • PDF

표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가 (Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target)

  • 최영세;박효국;김세영;김주호;이상규;윤종원;조정희
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.53-64
    • /
    • 2017
  • 목 적: 표적의 길이가 긴(length) 환자의 용적회전변조 방사선치료(V-MAT) 시 회전방향 오차의 크기에 따른 선량차이 경향을 $HexaPOD^{TM}$ evo RT system(6DoF couch)을 통해 알아보고 그 유용성을 평가하고자 하며, 이에 따른 회전오차 보정의 필요성을 제안하고자 한다. 대상 및 방법: 본원에서 치료를 받은 Esophagus cancer와 SCL을 포함한 Breast cancer 환자 중 HexaPOD 6DoF(Six-Degree of Freedom) couch를 사용한 10명을 대상으로 하였다. 6DoF couch를 이용하여 Rx(pitch), Ry(roll), Rz(yaw) 방향의 회전오차의 적용여부에 따른 선량차이를 알아보기 위하여 x, y, z축에 대한 자세오차를 확인하고, 자세 회전오차 값을 6DoF couch에 부여 임의의 오차를 발생시켜 변형된 선량계측 품질보증(Delivery Quality Assurance, DQA)을 시행, 점 선량과 감마값을 비교 분석하였다. 추가적으로 3cm의 직경에 5, 10, 15, 20 cm의 길이를 가진 각각의 표적의 치료계획에 회전오차의 크기를 $1^{\circ}$ 간격으로 적용한 후, 표적의 길이와 회전오차의 종류 및 크기에 따른 감마통과율의 변화양상을 확인했다. 결 과: 자세 회전오차가 적용된 경우의 점 선량과 감마통과율의 평균오차는 각각 Rx 방향에서 $2.50{\pm}1.11%$, $84.1{\pm}7.39%$, Ry 방향에서 $2.36{\pm}1.16%$, $81.0{\pm}8.49%$, Rz 방향에서 $2.35{\pm}1.10%$, $84.4{\pm}6.99%$를 나타냈다. 또한, 표적의 길이와 회전오차의 종류 및 크기에 따른 감마통과율 분석 결과 Ry 방향을 제외한 Rx와 Rz 방향에서 회전오차가 커질수록 감마통과율은 전반적으로 감소하는 경향을 보였으며, 특히 10 cm의 표적, Rz 방향으로 $2.5^{\circ}$ 회전오차가 부여된 경우에서 가장 낮은 감마통과율인 74.2 %를 나타냈다. 결 론: 표적의 길이가 긴 치료부위의 용적회전변조 방사선치료 시 회전오차의 보정은 필요하며, 6DoF couch의 사용은 환자자세의 재현성과 치료의 질적 효율을 높일 것으로 사료된다.

  • PDF