• 제목/요약/키워드: dose calibration

검색결과 179건 처리시간 0.037초

A REVIEW OF NEUTRON SCATTERING CORRECTION FOR THE CALIBRATION OF NEUTRON SURVEY METERS USING THE SHADOW CONE METHOD

  • KIM, SANG IN;KIM, BONG HWAN;KIM, JANG LYUL;LEE, JUNG IL
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.939-944
    • /
    • 2015
  • The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a $^{252}Californium$ ($^{252}Cf$) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1-9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered.

RALS시행시 선원의 거리 이동및 직장선량에 관한 계산치와 측정치의 비교연구 (Dose Distribution of Rectum in the treatment of Uterine Cervical Cancer using Remote Afterloading System)

  • 김성규;신세원;김명세
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.67-74
    • /
    • 1994
  • 선량분포특성은 거리의 제곱에 반비례하기 때문에 근접조사에서 선원의 조그마한 오차는 선량계산에서 큰 차이를 초래할 수 있어서 선원의 정확한 거리 이동과 그에 따른 critical organ에 조사되는 선량의 정확도는 자궁경부암 환자의 치료성적에 결정적인 역할을 할 수가 있다. 특히 High Dose Rate의 RALS(Remote After Loading System)에서 선원의 정확한 calibration은 자궁경부암 환자의 치료에서 선량분포에 지대한 영향을 미치며 나아가 이 선량분포는 치료후 나타나는 재발 및 합병증이나 휴유증의 발생에도 큰 영향을 미치게 된다. 본 연구에서는 실제 RALS시 선원의 거리 이동을 측정하여 치료계획용 computer에서 계산된 선원간의 거리 이동과 비교 검토하였으며 Rectum 위치에 chamber를 삽입하여 실제 Rectum에 조사되는 선량과 computer에서 계산된 값들을 비교검토하였다. Tandem Source을 1cm 간격으로 거리를 이동하면서 실험을 되풀이 한 결과 처음 monitor로 1cm을 이동할 때 측정치가 0.8cm 이동한 것으로 나타났으며, 2번째부터 5번째까지의 거리 이동에서는 monitor의 값과 측정치의 값이 정확하게 일치하였다. 또한 12명의 환자를 대상으로 실시한 Rectum dose의 측정치는 computer계산치보다 평균 8%로 낮게 나타났다.

  • PDF

고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교 (Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams)

  • 박창현;신동오;박성용
    • 한국의학물리학회지:의학물리
    • /
    • 제14권4호
    • /
    • pp.249-258
    • /
    • 2003
  • 흡수선량 측정의 정확성을 향상시키기 위하여 기존의 공기커마 혹은 조사선량 표준에서 물 흡수선량 표준으로 선량측정의 패러다임이 변화하고 있다. 본 연구는 기존의 프로토콜에서 물 흡수선량 기반의 프로토콜로의 전환을 모색하는 입장에서 현재 임상에서 널리 사용하고 있는 IAEA TRS­277과 물 흡수선량 표준에 토대를 두고 있는 IAEA TRS­398 및 AAPM TG­51 프로토콜에 대하여 동일한 기준깊이에서 물 흡수선량을 측정하여 상호 비교하였다. Varian 2100 C/D 선형가속기로부터의 세 종류의 전자선 에너지에 대해 PTW 30002 원통형 이온함과 Markus 및 Roos 평행평판형 이온함을 사용하여 측정하였고 $^{60}$Co에서의 공기커마 및 물 흡수선량 교정정수는 식품의약품안전청으로부터 받아 사용하였다. 공기커마 표준에 기반한 프로토콜과 물 흡수선량 표준에 기반한 프로토콜간에는 2% 이내의 차이를 보임으로써 사용자 기관에서는 자체적인 확인을 거쳐 공기커마 기반의 프로토콜에서 물 흡수전량 기반 프로토콜로의 전환을 적극 검토해 볼 필요가 있다. 물 흡수선량 기반의 프로토콜간에는 원통형 이온함의 경우 0.5% 이내에서 잘 일치하였고 평행평판형 이온함의 경우에도 고 에너지 전자선을 이용한 교차 교정을 하면 0.7% 이내에서 잘 일치하였다. 사용한 모든 프로토콜과 전자선 에너지에 대해 원통형 이온함과 평행평판형 이온함간에는 2% 이내의 차이를 보였으나 선량측정의 정확성을 향상시키기 위해 물 흡수선량 표준에 기반한 프로토콜의 권고에 따라서 하한에너지 이하의 전자선의 경우는 원통형 이온함 대신에 평행평판형 이온함을 사용함이 타당하다고 사료된다.

  • PDF

A Methodology of Dual Gate MOSFET Dosimeter with Compensated Temperature Sensitivity

  • Lho, Young-Hwan
    • 전기전자학회논문지
    • /
    • 제15권2호
    • /
    • pp.143-148
    • /
    • 2011
  • MOS (Metal-Oxide Semconductor) devices among the most sensistive of all semiconductors to radiation, in particular ionizing radiation, showing much change even after a relatively low dose. The necessity of a radiation dosimeter robust enough for the working environment has increased in the fields of aerospace, radio-therapy, atomic power plant facilities, and other places where radiation exists. The power MOSFET (Metal-Oxide Semiconductor Field-Effect Transistor) has been tested for use as a gamma radiation dosimeter by measuring the variation of threshold voltage based on the quantity of dose, and a maximum total dose of 30 krad exposed to a $^{60}Co$ ${\gamma}$-radiation source, which is sensitive to environment parameters such as temperature. The gate oxide structures give the main influence on the changes in the electrical characteristics affected by irradiation. The variation of threshold voltage on the operating temperature has caused errors, and needs calibration. These effects can be overcome by adjusting gate oxide thickness and implanting impurity at the surface of well region in MOSFET.

평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구 (Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber)

  • 라정은;신동오;박소현;정호진;황의중;안성환;임영경;김동욱;윤명근;신동호;이세병;서태석;박성용
    • 한국의학물리학회지:의학물리
    • /
    • 제20권2호
    • /
    • pp.97-105
    • /
    • 2009
  • 물 흡수선량표준을 기반으로 하는 선량측정 프로토콜에서는 전자선의 선질결정 지표는 $R_{50}$이며, 선량측정의 정확성을 향상시키기 위하여 전자선의 기준 에너지가 $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV)인 고에너지 전자선에서 표준기관에 소급성이 있는 원통형이온함의 물흡수선량교정계수을 이용한 평행평판형이온함의 교차교정을 권고하고 있다. 그러나 이러한 조건을 만족하는 고에너지 전자선은 모든 치료기관에서 보유하기가 어려운 실정이다. 따라서 본 연구에서는 평행평판형이온함의 교차교정 시 16 MeV 이상의 고 에너지 전자선뿐 아니라 12 MeV 이하의 전자선 에너지에서 얻은 평행평판형이온함의 교정계수를 이용하여 선량차이를 각각 비교하였다. 전자선 선량측정은 PTW 30013, Wellhofer FC65G의 Farmer형 원통형이온함과 PTW 34001, Wellhofer PPC40의 Roos형 평행평판형이온함을 이용하였으며 물팬텀내 기준깊이 $Z_{ret}=0.6R_{50}-0.1$(cm)에 원통형이온함과 평행평판형이온함을 같은 위치에 놓고 교차교정을 실시하였다. 교차교정 선질 20 MeV에서 결정된 교정계수를 적용한 물 흡수선량과 전자선에너지 12, 16 MeV에서의 물 흡수선량 차이는 0.2% 이내로 비교적 잘 일치하는 연구결과를 보였다. 그러므로 교차교정 선질 차이에 의한 흡수선량 값 상호 비교한 결과는 측정 불확도내에서 잘 일치하고 있어 각 기관에서 보유하고 있는 의료용가속기의 최고 전자선 선질에서의 교차교정도 유효하다고 사료된다.

  • PDF

Radiation exposure dose in human blood lymphocytes as assessed by the CBMN assay

  • Ryu, Tae Ho;Kim, Jin-Hong;Kim, Jin Kyu
    • Journal of Ecology and Environment
    • /
    • 제37권4호
    • /
    • pp.195-200
    • /
    • 2014
  • The chances of accidental exposure are augmented as the application of ionizing radiation increases in various fields. Such accidental exposures may occur at nuclear power plants, laboratories, and hospitals. Cytogenetic assays have been used for estimating radiation dose in the situation of the accidents. The micronucleus assay has several advantages over the other cytogenetic methods as it is simple and fast. The present study aimed at investigation of the micronuclei frequencies in cytokinesis-block cells in human blood lymphocytes after ${\gamma}$-irradiation and at establishment of a standard dose response relationship. The samples of peripheral blood were obtained from 6 different donors aged between 24 and 30 years old. The bloods were irradiated in vitro with 0-5 Gy. A linear quadratic dose-response equation was obtained by scoring the micronuclei in binucleated cells; $y=27.87x^2+46.13x+2.08$ ($r^2=0.99$). Irradiation caused a significant decrease in the nuclear division index. Necrotic and apoptotic cells increased in number after irradiation in a dose-dependent manner. In conclusion, the conventional cytokinesis-block micronucleus assay has proven to be the great technique in biological dosimetry. Dose-response calibration curve derived from CMBN assay could be used to estimate the exposure dose during a radiological emergency.

6 MeV 전자 빔의 교정에 원통형 이온함의 사용에 관한 연구 (The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam)

  • 김성훈;허현도;최상현;최진호;김혁주;임천일;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.317-323
    • /
    • 2009
  • 6 MeV 전자빔과 같은 저메가전압 전자빔 교정 시에 물흡수선량에 기반한 선량측정 체계에선 평행평판형 이온함을 사용하도록 하고 있다. 이러한 전자 에너지 범위에선 원통형 이온함을 정기적 기준 선량측정으로서 사용되어서는 안되지만, 사용자 편의상 임시적 사용 가능성에 대해 살펴보고자 하였다. 본 연구에선 빔 선질 $R_{50}=2.25\;g/cm^2$인 명목 에너지 6 MeV 전자빔의 경우에 원통형 이온함인 PTW30013 이온함의 사용가능성에 대해 조사하였다. 2차 표준기관인 식품의약품안전청(KFDA)으로부터 10개 이온함에 대해 물흡수선량 교정인자 $N_{D,W,Q_0}$를 받았다. 교차교정된 평행평판형 ROOS 이온함으로 6 MeV 전자빔에 대해 측정한 선량값을 사용하여 "임시적" $k_{Q,Q_0}$값을 구하였다. 10개의 이온함에 대해 평균한 값인 "0.9352"를 해당 선질에 대한 이온함의 $k_{Q,Q_0}$로 간주하여 흡수선량을 계산하였다. ROOS 이온함으로 측정한 선량값과 최대 2% 범위 안에서 일치하였다. 사용자 편의상 원통형 이온함을 사용해야 하는 경우에 이 "0.9352" 값을 본 연구의 빔선질과 이온함에 대한 빔선질보정인자로서 임시적으로 사용할 수 있으리라고 본다.

  • PDF

Dosimetry Check™를 이용한 MVCT 선량계산 모델 구축에 관한 연구 (A Study on the Construction of MVCT Dose Calculation Model by Using Dosimetry Check™)

  • 엄기천;김창환;전수동;백금문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.431-441
    • /
    • 2020
  • The purpose of this study was to construct a model of MVCT(Megavoltage Computed Tomography) dose calculation by using Dosimetry Check™, a program that radiation treatment dose verification, and establish a protocol that can be accumulated to the radiation treatment dose distribution. We acquired sinogram of MVCT after air scan in Fine, Normal, Coarse mode. Dosimetry Check™(DC) program can analyze only DICOM(Digital Imaging Communications in Medicine) format, however acquired sinogram is dat format. Thus, we made MVCT RC-DICOM format by using acquired sinogram. In addition, we made MVCT RP-DICOM by using principle of generating MLC(Multi-leaf Collimator) control points at half location of pitch in treatment RP-DICOM. The MVCT imaging dose in fine mode was measured by using ionization chamber, and normalized to the MVCT dose calculation model, the MVCT imaging dose of Normal, Coarse mode was calculated by using DC program. As a results, 2.08 cGy was measured by using ionization chamber in Fine mode and normalized based on the measured dose in DC program. After normalization, the result of MVCT dose calculation in Normal, Coarse mode, each mode was calculated 0.957, 0.621 cGy. Finally, the dose resulting from the process for acquisition of MVCT can be accumulated to the treatment dose distribution for dose evaluation. It is believed that this could be contribute clinically to a more realistic dose evaluation. From now on, it is considered that it will be able to provide more accurate and realistic dose information in radiation therapy planning evaluation by using Tomotherapy.

양방사선 골밀도 측정 장치의 공간산란선량분포측정 (Bone Density Spatial Distribution of Radiation Dose Measurement)

  • 김선칠;원도연;박창희;동경래
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.59-62
    • /
    • 2011
  • In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation $0^{\circ}$ head end was higher in the direction of the highest dose rate, $0^{\circ}$ $180^{\circ}$ direction from the direction towards the higher dose rate reduced to some extent in the direction of all the $120^{\circ}$ were able to identify.

  • PDF

식품의약품안전청의 치료방사선 선량보증과 측정불확도 (KFDA TLD Dose Quality Audit and Measurement Uncertainty)

  • 정희교;이현구;김귀야;양현규;임천일
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.153-156
    • /
    • 2004
  • 식품의약품안전청은 1978년 12월 방사선 분야의 국가교정검사기관으로 지정되어 현재까지 Co-60선원을 이용 치료준위 방사선측정기에 대한 교정을 수행하고 있다. 식약청의 에어커마와 물 흡수선량 측정값은 국제도량형국(BIPM)과 측정소급성을 유지하고 있으며, 교정계수의 확장불확도는 0.9 %(k=2)이다. 식약청에서는 외부방사선에 대한 선량보증의 일환으로 1999년 전리함을 이용하여 방사선치료기관의 선량측정을 수행하였으며, 2002년부터 열형광선량계(TLD)를 이용한 선량측정체계를 확립 ${\cdot}$ 운영하고 있다. TLD 판독에 대한 측정불확도는 1.6 %(k=1)이며, 측정불확도를 감안하여 선량보증의 허용한계를 ${\pm}$ 5 %로 설정하였다. TLD 판독값을 선량으로 전환하는 과정에서 선질, 비선형성, 홀더사용 등의 영향을 보정하기 위한 보정정수를 사용하였다. 2003년도 치료방사선 선량보증사업에는 53개 기관(71개 선질)이 참여하였다. 선량보증 결과 71개 선질 중63개 선질(89 %)이 1차 측정에서 허용한계를 만족하였다. 허용한계 초과기관에 대해서는 재측정을 수행하였고, 그 결과 모두 허용한계 이내의 값을 나타냄을 확인하였다.

  • PDF