• 제목/요약/키워드: doping test

검색결과 70건 처리시간 0.028초

보중치습탕(補中治濕湯)의 도핑검사 대상약물(對象藥物)에 관(關)한 연구(硏究) (A Study on Doping Test of Bojungchisheup-tang)

  • 김성용;금동호;이명종
    • 한국한의학연구원논문집
    • /
    • 제3권1호
    • /
    • pp.289-319
    • /
    • 1997
  • Non-medical use of drugs to enhance performance at Olympic Games by athletes has been prohibited by the International Olympic Committee(IOC) since 1968 on medical and ethical grounds. IOC wants to protect athlete from harmful side effect of drugs due to misuse of it. It also, ethically, wants to have Games run on fair base, not fortified by performance enhancing drugs, The banned substances include stimulants, narcotic analgesics, anabolic sterolds, ${\beta}-blockers$ and diuretics. In order to prevent the positive reaction in the doping test induced by herb medicine, this study was done on about Bojungchisheup-tang. The laboratory set up doping analyses methods to cover as many drugs as possible without sacrificing sensitivity and specificity within one procedure. Its screening method consisted of four different procedures. The results were negative. According to the above results, Bojungchisheup-tang taken by athletes would show the negative reaction in the doping test. So its prescription for athletes can be given without worries of the doping test.

  • PDF

한약의 도핑 안전성에 대한 고찰 (A Review on Safety of Herbal Medicines for Doping)

  • 김주란;윤성중;이윤규;이현종;김재수
    • 대한한의학회지
    • /
    • 제40권3호
    • /
    • pp.139-176
    • /
    • 2019
  • Objectives: This study aims to review the herbal medicines containing substances banned by World Anti-Doping Agency(WADA), and to consider criteria for the using of herbal medicines. Methods: Using foreign(Pubmed, Cochrane, Embase, Google Scholar, WANFANG, CiNii) and domestic databases (NDSL, OASIS, RISS), we analyzed the content and pharmacokinetics of the prohibited substances in herbal medicines. Results: Herbal medicines containing the prohibited substances proposed in Korea, China, and Japan are Ephedrae Herba, Cannabis Semen, Strychni Semen, Strychni Ignatii Semen, Pinelliae Tuber, Rhizoma Pinelliae, Chelidonii Herba, Papaveris Fructus Deseminatus, Liriopis Tuber, Rehmanniae Radix Recens, Cistanchis Herba, Ponciri Fructus Immaturus, Aurantii Fructus Immaturus, Moschus, Testudinis Plastrum, Otariae Testis et Penis, and Hominis Placenta. Of these, when using Ephedrae Herba, Cannabis Semen, Strychni Semen, Moschus, Strychni Ignatii Semen, and Otariae Testis et Penis, caution is needed in relation to the doping test. Other herbal medicines are considered safe for the doping test. In addition, by analyzing data related to higenamine added to the WADA's prohibited list of doping since 2017, we don't recommend using Nelumbinis Plumula. And in the case of the other herbal medicines containing higenamine, it is considered that care should be taken in doping test depending on the amount of usage. Conclusions: As a result of analyzing the herbal medicines which are in prohibited list about doping, we were able to know the criteria and precautions to use when prescribing the herbal medicines. Further research will be needed about common used herbal medicines and the amount of detection depending on extraction and boiling method.

A Simple Device of the Dry Tetrabromophenolphthalein Ethyl Ester Reagent Strip for the Detection of Methamphetamine

  • Choi, Myung-Ja;Song, Eun-Young;Kim, Seung-Ki;Choi, Jeong-Eun;Lho, Dong-Seok;Park, Jong-Sei
    • Archives of Pharmacal Research
    • /
    • 제16권3호
    • /
    • pp.227-230
    • /
    • 1993
  • A new device to detect methamphetamine (MA), amphetamine(A) and its metabolites in urine was developed using the paper strip method and the test tube method of dry chemical reagents. The reagent containing tetrabromophenolphthalein ethyl ester (TBPE) and borax. For the TBPE paper strip method, a device was prepared with a window at each end of the reagent paper strip ; one window is for the sample application, and the other window is for the methylene chloride. The diffused sample from one window reacts with reagent in the paper and produces color at the point where it meets with methylene chloride which has diffused form the other side. A positive smaple produces as red-purple color and the negative sample a greenish color, with a detection limit of 5-10 ppm. The result can be obtained within one minute. For the TBPE test tube method which contains dry reagents, the detection limit is 5 ppm and the result can be obtaineed within 30 seconds, however the carry-on is not as convenient as the paper strip method. The performance of both methods were evlauated by comparing with the results of gas chromatography (GC) and fluorescence polarizaiton immunoassay (FPIA). The results were proven that both methods were useful as primary screening reagents to detect MA in urine and in dry powder.

  • PDF

CAS의 결정례로 본 도핑 위반 사건의 법리 (The Jurisprudence on Anti-Doping Rule Violation through Review of CAS Awards)

  • 김현숙
    • 한국중재학회지:중재연구
    • /
    • 제28권1호
    • /
    • pp.77-97
    • /
    • 2018
  • The Court of Arbitration for Sport (CAS) has been adjudicating on sports-related disputes since 1984. CAS can be regarded as world supreme court for sports settling down about 4200 cases including doping issues. Doping disputes are generally processed by CAS Appeals division and Anti-Doping Division. An appeal against the decision by sports-related bodies may be filed with CAS Appeals Division. Doping issues concerning Olympic games are on Anti-Doping Division, introduced from 2016 Olympic games and invested with complete authority by IOC. The Award of Maria Sharapova finds a player is responsible if found to have committed any Anti-Doping Rule Violation regardless of his/her intention or fault. It offers detailed jurisprudence on imposing such a specific period of ineligibility in view of the totality of the circumstances. The award of Xinyi Chen also confirms the Strict Liability Rule on anti-doping disputes. The player appealed there could be either accidental contamination of drinks, or doping laboratories' mistakes that affected the test results. But, all of them were rejected. Though dealing with doping disputes in a timely manner is important for seasonal sports events like Olympic games, it is necessary to prepare the acceptable and fair process for the players in the future.

운동선수들의 혈액분석을 통한 Etrythropoietin 간접도핑검사 (Blood Analysis for Indirect Doping Control of Erythropoietin in Sports)

  • 이정란;김소영;홍지연;김명수;최명자
    • 약학회지
    • /
    • 제47권6호
    • /
    • pp.422-431
    • /
    • 2003
  • The use of recombinant human erythropoietin (rhEPO), a stimulator of erythropoiesis, banned in sports because of the medical risk associated with thrombosis. Due to analytical difficulties to differentiate between natural human EPO (hEPO) and rhEPO, blood parameters of erythropoiesis such as contents of hemoglobin (cut-off value <17.5 g/d l for man, and < 16.0 g/dl for women), hematocrit and reticulocytes (cut-off value <2.0%) were measured to focus the misuse of rhEPO. We conducted anti-doping test for 122 blood samples of the World Cup athletes. The mean values of key parameters are as follows; 14.5$\pm$1.0 g/dl for hemoglobin, 41.7$\pm$2.8% for hematocrit, and 1.3$\pm$0.4% for reticulocyte. Blood sample was found to be stable up to 8 hours for the reticulocyte measurement. In addition, the soluble transferrin receptor and ferritin levels were measured by immunoassay methods using plasma samples (n=28) in which the mean value was 0.8$\pm$0.5 $\mu\textrm{g}$/$m\ell$ and 54.6$\pm$33.7 ng/$m\ell$, respectively. The results indicate that all samples tested were negative for the blood parameters of indirect anti-doping test for hEPO misuse. The statistical evaluation suggest that several other parameters such as red blood cell, mean corpuscular hemoglobin concentration, mean corpuscular volume, mean corpuscular hemoglobin and white blood cell could be considered as factors influencing hEPO function in addition to five parameters mentioned.

Performance Characteristic of the β-Human Chorionic Gonadotropin Assay on the Access 2 for Its Use in Doping Control

  • Kang, Min-Jung;Lee, Hye-Im;Shin, Sang-Mi;Yoo, Hye-Hyun;Kwon, Oh-Seung;Jin, Chang-Bae;Chung, Bong-Chul
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권10호
    • /
    • pp.2889-2892
    • /
    • 2010
  • The objective of this study was to validate performance characteristics of the Access 2 (Beckman coulter) system for hCG assays for use as a confirmation test for doping control. The Access 2 assay was linear up to 500 IU/L. The correlation coefficient was higher than 0.999, and the sensitivity of the linearity was 0.82. There were no false positive or false negative cases. LOD was 0.59 IU/L. The method was robust when performed by different people. Repeatability and reproducibility were below 7%. We compared reproducibility and recoveries of Access 2 and Elecsys 2010. Access 2 demonstrated higher reproducibility than Elecsys 2010. Recoveries (accuracy) of Access 2 were between 85 and 105%. Recoveries for Elecsys 2010 were between 91 and 104%.

저압 CVD에 의한 $Si_{0.8}Ge_{0.2}$ epitaxial growth에 대한 Phosphorus doping 효과 (Phosphorus doping effect on $Si_{0.8}Ge_{0.2}$ epitaxial growth by LPCVD)

  • 이철진;엄문종;성만영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.314-316
    • /
    • 1997
  • We have studied the epitaxial growth and electrical properties of $Si_{0.8}Ge_{0.2}$, films on Si substrates at $550^{\circ}C$ by LPCVD. In a low $PH_3$, partial pressure region such as below 1.25 mPa, the phosphorus doping concentration increased proportionally with increasing $PH_3$ partial pressure while the deposition rate and the Ge fraction x were constant. In a higher $PH_3$ partial pressure region, the phosphorus doping concentration and the deposition rate decreased, while the Ge fraction slightly increased. The dependence of P incorporation rate on the $PH_3$ partial pressure was similar to the phosphorus doping concentration. According to test results, it suggests that high surface coverage of phosphorus atoms suppress both the $SiH_4$ adsorption/reaction and the $GeH_4$ adsorption/reaction on the surfaces, and the effect is more stronger on $SiH_4$ than on $GeH_4$. In a higher $PH_3$ partial pressure region, the deposition is largely controlled by surface coverage effect of phosphorus atoms.

  • PDF

Optimizing the Performance of Three-Dimensional Nitrogen-Doped Graphene Supercapacitors by Regulating the Nitrogen Doping Concentration

  • Zhaoyang Han;Sang-Hee Son
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.376-384
    • /
    • 2023
  • Nitrogen-doped graphene was synthesized by a hydrothermal method using graphene oxide (GO) as the raw material, urea as the reducing agent and nitrogen as the dopant. The morphology, structure, composition and electrochemical properties of the samples are characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared (FTIR) spectroscopy, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), nitrogen adsorption-desorption analysis, electrical conductivity and electrochemical tests. The results show that urea can effectively reduce GO and achieve nitrogen doping under the hydrothermal conditions. By adjusting the mass ratio of raw materials to dopants, the graphene with different nitrogen doping contents can be obtained; the nitrogen content range is from 5.28~6.08% (atomic fraction percentage).When the ratio of dopant to urea is 1:30, the nitrogen doping content reaches a maximum of 6.08%.The supercapacitor performance test shows that the nitrogen content prepared by the ratio of 6.08% is the best at 0.1 A·g-1. The specific capacitance is 95.2 F·g-1.

Validation and Applications of Gas Chromatography-Combustion/isotope Ratio Mass Spectrometric Method to Control Misuse of Androgens in Human

  • Lee, Kang-Mi;Kim, Ho-Jun;Jeong, Eun-Sook;Yoo, Hye-Hyun;Kwon, Oh-Seung;Jin, Chang-Bae;Kim, Dong-Hyun;Lee, Jae-Ick
    • Mass Spectrometry Letters
    • /
    • 제2권2호
    • /
    • pp.33-36
    • /
    • 2011
  • The misuse of anabolic androgenic steroids is of particular concern in sports and society. Thus, it is of great importance to discriminate endogenous steroids such as testosterone or testosterone prohormones from their chemically identical synthetic copies. In this study, gas chromatography-combustion/isotope ratio mass spectrometric (GC-C/IRMS) method has been developed and validated for discriminating the origin of anabolic androgenic steroids. The method involves the solid-phase extraction, enzymatic hydrolysis with ${\beta}$-glucuronidase, HPLC-fractionation for the cleanup and analysis by GC-C/IRMS. The difference(${\Delta}^{13}C$) of urinary ${\delta}^{13}C$ values between synthetic analogues and endogenous reference compounds (ERC) by GC-C/IRMS was used to elucidate the origin of steroids, and intra- and inter-day precision, specificity and isotope fractionation were evaluated. The present GC-C/IRMS method combined with HPLC cleanup was accurate and reproducible enough to be successfully applied to the test of urine sample from suspected anabolic steroid abusers.

Comparative Free and Acetylated Polyamine Profiles in the Urine of Normal Subjects and Various Cancer Patients

  • Suh, Ja Won;Lee, Seon Hwa;Park, Young Han;Chung, Bong Chul;Park, Jongsei
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.895-900
    • /
    • 1995
  • Urinary free and acetylated polyamine profiles have been investigated for their potential usefulness as biochemical markers of cancer in a control of group comprised of healthy volunteers (32 cases) and patients with various types of cancers(48 cases). The nine (5 free and 4 acetylated) endogeneous polyamines were simultaneously determined by a sensitive capillary gas chromatography/nitrogen-phosphorus detector (GC/NPD). The newly modified (simple and convenient) method was developed and the compounds were isolated by adsorption onto silica gel and derivatized by heptafluorobutyric anhydride to enhance their specificity on gas chromatograms. The good quality-control data were obtained through the precision and accuracy test and the recovery range of them was 48.6 ~ 101.2 %. The Korean reference values of urinary polyamines were established and significant differences were found in cancer patients compared with normal subjects. Also, to eliminate subject variations, precursors to product concentration ratios were compared between cancer patients and control group. The ratios of both putrescine to spermidine and total (free plus acetylated) putrescine to total spermidine were significantly greater in cancer patients than in normal subjects.

  • PDF