• Title/Summary/Keyword: division level

Search Result 7,612, Processing Time 0.037 seconds

Promotion Strategy of Item Level RFID by Demand Analysis (Item Level RFID 수요분석을 통한 활성화전략)

  • Park, Yong-Jae;Rim, Myung-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.837-840
    • /
    • 2009
  • In recent years, Item Level RFID market, attaching RFID instead of barcodes to individual units for item rather than box and pallet units, is expected to expand both domestically and internationally in the future. In this study, by analyzing the demand for Item Level RFID services which apply RFID to the individual units, we would like to come by strategies that promote and develop RFID industry. This study consists of the following contents. First, we analyzed trends in domestic and overseas markets of Item Level RFID. Second, we surveyed the RFID demanding companies and analyzed Item Level RFID promising service sector, the expected leading field of market, the leading field of dissemination, and the obstacles of its introduction. Finally, on the basis of the results of the empirical study, we presented the strategies to promote Item Level RFID.

  • PDF

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

Synchronization System of Robot-centered Information for Context Understanding (상황 이해를 위한 로봇 중심 정보 동기화 시스템)

  • Lim, G.H.;Lee, S.;Suh, I.H.;Kim, H.S.;Son, J.H.
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.933-934
    • /
    • 2006
  • High level perceptual tasks such as context understanding, SLAM and object recognition are essential for intelligent robot to provide services for human supports. Those intelligent robots often use camera sensor for vision information, sonar or laser sensor for range information, encoder for angular velocity of wheel and so on. The information is generated at different time intervals by the different H/W devices and S/W algorithms. The generation of high level information requires the specific mixture of low level information. And the information should be represented to be useful for robots to use in their ecological niche. In conventional robot systems, perceptual module requires the resource to use by tightly coupling whenever it is needed. So the resource and information cannot be easily shared and even could be invalid for the delayed information. In this paper, we propose a synchronization system of robot-centered information for context understanding. Our system represents information for the robot capacity and synchronizes the information that is asynchronously generated, where is employed the black-board architecture.

  • PDF

Multilevel modeling of diametral creep in pressure tubes of Korean CANDU units

  • Lee, Gyeong-Geun;Ahn, Dong-Hyun;Jin, Hyung-Ha;Song, Myung-Ho;Jung, Jong Yeob
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4042-4051
    • /
    • 2021
  • In this work, we applied a multilevel modeling technique to estimate the diametral creep in the pressure tubes of Korean Canada Deuterium Uranium (CANDU) units. Data accumulated from in-service inspections were used to develop the model. To confirm the strength of the multilevel models, a 2-level multilevel model considering the relationship between channels for a CANDU unit was compared with existing linear models. The multilevel model exhibited a very robust prediction accuracy compared to the linear models with different data pooling methods. A 3-level multilevel model, which considered individual bundles, channels, and units, was also implemented. The influence of the channel installation direction was incorporated into the three-stage multilevel model. For channels that were previously measured, the developed 3-level multilevel model exhibited a very good predictive power, and the prediction interval was very narrow. However, for channels that had never been measured before, the prediction interval widened considerably. This model can be sufficiently improved by the accumulation of more data and can be applied to other CANDU units.

Development of Piezoelectric Level Switch for High Temperature (고온용 압전 레벨 스위치 개발)

  • Kim, Na-Ri;Lee, Young-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.802-807
    • /
    • 2015
  • This paper describes the development of a piezoelectric level switch, which aims to effectively monitor the level status in high ambient temperatures. In order to adjust the impedance near the resonant frequency and temperature characteristics, the effect of the case and backing layer materials on its performance was analyzed using the finite element method (FEM). The suggested prototype new level switch has three heat-sink plates attached to SUS bar of 230 mm long, and case of PEEK which contains PZT sensing part. To illustrate the validity of this level switch, 10 samples are prepared and investigated the sensing performance through the high and low temperature ambient.

Study on the pre-tilt level and uniformity of low rotational viscosity LC for fast response time

  • Lee, D.J.;Hwang, J.I.;Ko, T.W.;Choi, H.C.;Lee, S.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.457-459
    • /
    • 2005
  • Low viscosity LCs have been developed for fast response time improvement of the TFT-LCD Monitors based on TN mode. This low viscosity characteristic s cause the pretilt angle to be changed and the uniformity to degrade. We have studied on the pretilt angle effect by the various components used for low viscosity LCs. We prepared the panels by using these various components and measured pretilt angle for this research. As a result of this research, we have found out that each low viscosity component has the different pretilt angle level and uniformity. For good display quality, it is important to keep the stable pretilt angle. The low viscosity LCs with this stable pretilt angle make it possible to prepare the high performance TFT-LCD Monitor with both fast response time characteristics and good display quality

  • PDF

Instruction-Level Power Estimator for Sensor Networks

  • Joe, Hyun-Woo;Park, Jae-Bok;Lim, Chae-Deok;Woo, Duk-Kyun;Kim, Hyung-Shin
    • ETRI Journal
    • /
    • v.30 no.1
    • /
    • pp.47-58
    • /
    • 2008
  • In sensor networks, analyzing power consumption before actual deployment is crucial for maximizing service lifetime. This paper proposes an instruction-level power estimator (IPEN) for sensor networks. IPEN is an accurate and fine grain power estimation tool, using an instruction-level simulator. It is independent of the operating system, so many different kinds of sensor node software can be simulated for estimation. We have developed the power model of a Micaz-compatible mote. The power consumption of the ATmega128L microcontroller is modeled with the base energy cost and the instruction overheads. The CC2420 communication component and other peripherals are modeled according to their operation states. The energy consumption estimation module profiles peripheral accesses and function calls while an application is running. IPEN has shown excellent power estimation accuracy, with less than 5% estimation error compared to real sensor network implementation. With IPEN's high precision instruction-level energy prediction, users can accurately estimate a sensor network's energy consumption and achieve fine-grained optimization of their software.

  • PDF

Numerical Analysis of Hydrograph Determination for Cohesive Soil Levee (조립토 하천제방의 수위파형결정에 관한 수치해석적 연구)

  • Kim, Jin-Man;Kim, Ji-Sung;Oh, Eun-Ho;Cho, Won-Beom
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.4
    • /
    • pp.81-92
    • /
    • 2014
  • The integrity evaluation of river levee includes slope stability evaluation of riverside land and protected low-land, and safety of piping with respect to critical gradient and critical velocity based on related regulations, such as Design Criteria Rivers Commentary (2009), Structural Design Criteria Based Commentary (2009). The design hydro-graph is the most important design input factor for the integrity evaluation; it can be inaccurate due to the absence of its decision methods suggested by the national level. The authors in this paper evaluated numerical analytic levee integrity for piping and slope stability by changing each design hydro-graph, including rising ordinary water level, lasting flood water level, falling water level, and flood frequency for Mun-san-jae on Nak-dong River. Finally, the authors suggested that the levee integrity of piping and slope stability are very sensitive to the changes of increasing time of ordinary water level by 57 hours and lasting time of the flood water level by 53 hours, respectively, for Mun-san-jae.

Calcium Signaling of M II Oocyte during Chemical Activation of Calcium Ionopore and Cytochalasin B

  • Kim, Sung-Woo;Park, Jin-Ki;Park, Chun-Gyu;Lee, Ju-Young;Han, Joo-hee;Lee, Seung-Eun;Baek, Kyung-Nye;Chang, Won-Kyung
    • Proceedings of the KSAR Conference
    • /
    • 2004.06a
    • /
    • pp.260-260
    • /
    • 2004
  • The calcium ionophore (A23187) has been used for activation of porcine oocytes from in vitro maturation by many researches. The signaling of calcium was known to be a primary factor of activation of MII oocyte by calcium ionophore. The calcium level was measured by an intensity of fluo 4 fluorescence and confocal microscope. The level was increased by 7% ethanol or 70 μM calcium ionophore but oscillation was not found. (omitted)

  • PDF