• 제목/요약/키워드: distribution System

검색결과 15,379건 처리시간 0.083초

배전계통 최적기본신뢰도 지수 평가를 위한 유전자 알고리즘의 적용 (Assessment of the optimal basic reliability in distribution system using genetic algorithm)

  • 김재철;한성호;이보호;이욱;장정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.64-66
    • /
    • 1995
  • This paper presents a new approach to evaluate optimal basic reliability indices of electric distribution systems using genetic algorithm. The use of optimal reliability evaluation is an important aspect of distribution system planning and operation to determine adequacy reliability level of each area. In this paper, the reliability model is based on the analytical method, connecting component failure to load point outage in each section. The proposed method applies genetic algorithm to calculate the optimal values of basic reliability indices, ie. failure rate and repair time, for a load point in the power distribution system, subject to minimizing interruption cost. Test results for the model system are reported in the paper compared with a direct optimization method(gradient projection).

  • PDF

154 kV 변전소 주변압기의 용량 및 운전조건이 22.9 kV 배전계통의 고장전류에 미치는 영향 (An Investigation on the Fault Currents in 22.9 kV Distribution System Due to the Increased Capacity and Operating Conditions of Power Transformers in 154 kV Substation)

  • 조성수;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.302-310
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity and operating conditions of power transformers in 154 kV substation, the fault currents in distribution system were calculated by the conventional method and simulations of PSCAD/EMTDC program. Consequently, under the condition of the parallel operation of transformers, the fault currents exceed the nominal current of the breakers in some areas. Without NGR at the secondary neutral of the transformer, the current of single line-to-ground fault was bigger than that of 3-phase fault. Therefore, the results clearly show that the measures to limit the fault currents in distribution system are needed when the increased capacity of power transformers is introduced into 154 kV substation.

배전 자동화 시스템을 위한 데이타베이스 설계 (Database Design for the Automatic Distribution System)

  • 김상욱;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.754-757
    • /
    • 1997
  • Effective design of a database is essential for operating application systems efficiently. This Paper discusses database design for the automatic distribution system. Database design is a complex Process for specifying the structure of information and is decomposed in three Phases: conceptual, logical, and Physical design. In this paper, we first collect and analyze the requirements for the automatic distribution system, our target application. We also perform database design for these requirements through three design Phases. We believe that our results would contribute to the effective construction of a database for the automatic distribution system.

  • PDF

Mathematical description of drug distribution in the isolated organ

  • Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • 제3권1호
    • /
    • pp.13-16
    • /
    • 1980
  • The model of an isolated organ system has been constructed to simulated the behavior of drug in the circulatory system of an acting organ or site. The model is developed on the following assumptions : The drug in the microcirculatory system cannot permeate the capilary walls. The capilary bed is modeled as a simple ideal plug flow system with and without radial concentration gradient. The mathematical model is developed from basic considerations of drug distribution with hemodynamical and pharmacokinetical meanings. It is considered that a nonmetabolic drug substance is injected into the arterial inflow site of an isolated organ at a constant rate. The concentration of the drug in the outflow site is mathematically expressed as a function of time.

  • PDF

국내 상수관로에 대한 THM 발생 예측모델의 적용 (Application of THM Predictive Model in Water Distribution System)

  • 이두진;김영일;손진식
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.3-11
    • /
    • 2007
  • THM models have been developed in several researchers in order to better understand and manage the presence of THM in water distribution system. Several developed models were demonstrated in this study for estimating THM concentrations in target water distribution system. In order to investigate the performance of developed THM models, lab and field test were investigated. Predicted THM concentrations by all kind of models were showed good correlation with observed values. When the developed models were compared with lab and field test, the Rodriguez model during tested models was most predictive than the other models.

소형 열병합 발전설비가 연계된 배전계통의 순시전압변동 (Momentary Voltage Dips in the Power Distribution System Interconnected with Cogeneration Facilities (COGN))

  • 최준호;김재철;정성교;김대원;한성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1088-1090
    • /
    • 1998
  • The cogeneration facilities (COGN) into the power distribution system can cause operational problems - reenergization of distribution feeders under repair by utility personnel, voltage variation and regulation because of output power of COGN, and lost of coordination at emergency state - on an electrical utility system. This paper deals with momentary voltage dips as the parallel interconnection operation of COGN in the power distribution system. PSCAD/EMTDC simulation tool is used to show the behavior of momentary voltage dips. In addition, restraint solution for momentary voltage variation is presented.

  • PDF

객체지향형 실시간 배전자동화시스템 데이터베이스 구축을 위한 개념디자인 (An Conceptual Design for the On-Line Automatic Distribution system Database using Objected-Oriented Concept)

  • 최상열;김지형;신명철;남시복;박남옥;이복구;조팔훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1137-1139
    • /
    • 1998
  • Effective database is the key to manage automatic distribution system. Currently, automatic distribution system database has been studied with a relational concept. But, it is hard to describe the characteristic of automatic distribution system data which require real time management and composite type. This paper present the way how to design conceptual schema for EMS database using object-oriented concept which is free to decribe composite data type and support inheritance concept.

  • PDF

가압식 바닥급기 시스템의 여름철 성층화 경향에 관한 실험적 연구 (An Experimental Study on Thermal Stratification of Pressurized Plenum Underfloor Air Distribution System during Cooling)

  • 김동희;유기형;조동우;서정석;한성필
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.340-345
    • /
    • 2007
  • The underfloor air distribution system has been attracting to architects and building owners as one of valuable system for the renovated and newly office building. In this paper, we discussed the thermal stratification profile of pressurized plenum underfloor air distribution(UFAD) according to indoor setting temperature, diffuser number, diffuser type. For this, the space of office building(H corp.) is selected for measuring the air volume of underfloor diffuser and vertical temperature profile. As a result, the thermal stratification profile is influenced by the number and type of the underfloor diffuser and thermal storage character of the underfloor. Whereas indoor setting temperature have a lower significant impact on thermal stratification.

  • PDF

루프 배전계통에서 Agent를 이용한 보호협조 및 자동정정 방법에 관한 연구 (A Study on the Protective Coordination and Automatic Setting Method using Agents in Distribution System with Loop)

  • 진영택;이승재;최면송;임성일;김태완
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1107-1114
    • /
    • 2012
  • In this paper, we propose protective coordination and automatic setting method using agents for distribution system with loop. The proposed protection scheme adopts an agent technology assuming communication among protection agents and auto-switch agents. Having exchanged fault-related information with each other, protection agents and auto-switch agents perform the primary and backup protection and fault section isolation, respectively. this proposed scheme using agents for distribution system with loop is implemented by matlab. Because of the various configuration of distribution system, It's difficult to find cooperative agents for each agent. This paper develops a program to automatically set the cooperative route for the agents.

The FRTU-Based Intelligent Fault Location Determination Strategy in Ubiquitous Based Distribution Systems

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.192-198
    • /
    • 2008
  • This paper proposes a FRTU-based intelligent fault distance determination strategy in which each FRTU is able to avoid multiple estimations and reduce the level of estimation error by utilizing heuristic rules driven by voltage and current information collected by 1:1 communication with other FRTUs from the same zone in a ubiquitous-based distribution system. In the proposed method, each FRTU, at first, determines a fault zone and a fault path on the faulted zone based on the proposed heuristic rules which use its current data and the voltage data of its neighboring FRTUs as input data. Next, it determines the fault distance from its position based on the fault current estimated from the current data of the neighboring FRTUs. Finally, in order to prove the effectiveness of the proposed method, the diverse fault cases are simulated in several positions of the typical distribution system using the EMTP.