• Title/Summary/Keyword: distribution System

Search Result 15,350, Processing Time 0.043 seconds

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

A Study on Publishing Distribution System Application for RFID System (출판유통 RFID 적용에 관한 연구)

  • 안종윤;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.1
    • /
    • pp.125-133
    • /
    • 2004
  • Greeting the globalization and information period of 21C, the improvement of the distributional system structure and modernization of publishing distribution are the seriously required periodic assignments for the publishing industry that is a national knowledge and culture industry to be equipped with the core competitiveness. First, it is to found a large distributional organization that is able to provide total logistics services in time that is essential to the publishing company and bookstore. Second, it is to have a logistics service to act up to the variable requirements of customers such as publishing companies and bookstores under the rapidly changing distribution environment. Third, it is to provide the standardized information of publishing distribution. It is needed to establish a total distributional center in collaboration to satisfy the requirements of publishing industry as above. By doing this work, structure of the publishing distribution system can be improved and its constitution can be strengthen, and it is possible not only to construct a stable supply system but also to realize an information-based system in the publishing industry with the construction of information system and its utilization. Furthermore, the application of RFID in the publishing distribution is essentially required to provide the symbolic model and logistics infrastructure into the 'Paju publishing culture information industrial complex'. It could be possible by growing the international recognition regarding distribution environment and strengthening the international competitiveness in the period of the ""Open door".

A Study on the Priority Decision for Interconnection of PV System on Power Distribution System considering Customer Interruption Costs (정전비용 고려한 PV시스템의 배전계통 연계 우선순위 결정에 관한 연구)

  • Son, Chang-Nam;Han, Woon-Dong;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.163-168
    • /
    • 2014
  • In this paper, when photovoltaic systems are connected to distribution system, most effective capacity and location of PV system are studied considering customer interruption costs of power distribution system. The reliability model of PV system considering the duration of sunshine, the model of time-varying load and Roy Billinton test system (bus2 model) are used. To simulate the effects of PV system, various cases are selected; (1) base case which is no connection of PV system to power distribution system when faults are occurred, (2) 3MW case which is 3[MW] connection of PV system (3) 4[MW] case, and (4) 20[MW] case which is 20[MW] connection of PV system to the bus of power distribution system. The capacity limit of connected PV system is settled to 14[MW] for all cases except case 4. The reliability and customer interruption costs for residential, general, industrial, and educational customer is evaluated.

A study on the development of distribution simulator and simulation results for use in distribution automation system of IEC 61850 protocol (IEC 61850 프로토콜의 배전자동화시스템에 사용을 위한 배전시뮬레이터 개발과 시뮬레이션 결과에 관한 연구)

  • Kim, Jae-Hong;Oh, Jae-Gon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • It is a study for the evaluation of the stability of the distribution automation system for the expansion of renewable energy. Through the Renewable Energy 3020 Implementation Plan, the government plans to expand new renewable energy and convert it to participatory energy that improves the quality of life of the people by 2030. The government has set a target of 20% of domestic supply energy for renewable energy generation by 2030. It is planning to establish more than 95 percent of its new facilities with clean energy such as solar power and wind power. By expanding the supply of renewable energy, new energy businesses and distributed power industry were fostered, and short-distance, low-voltage, and small-scale power generation were rapidly expanded rather than large-scale power development in the past. Due to this demand, the importance of power distribution facility operation has emerged and the need for distribution automation system is increasing. This paper discusses the development of a power distribution simulator for the performance and function evaluation of power distribution automation systems and presents the results of an interlocking test with the power distribution automation system. In order to introduce an advanced system into the power distribution system, it is necessary to take advantage of the transmission and distribution system. The DNP3.0 protocol is used in the distribution system and the IEC61850 protocol is used in the transmission and distribution system. It was concluded that the functions and performance of operations were satisfied when these two protocols are mixed and used in the distribution automation system.

A Study About Distribution Automation System Based on CIM (CIM 기반의 Distribution Automation System에 관한 연구)

  • Lee, Hee-Joo;Seo, Jeong-Il;Han, Ju-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.913-920
    • /
    • 2011
  • Distribution systems for operating the various systems should be operated organically. Distribution systems for organic operations extend the functionality of the system and system integration for the extension is doing. However, in systems integration for each unique non-standard definition of linkage and exchange systems are used. Non-standard definition of a unique linkage and exchange systems in the maintenance and expansion will result in many negative results. To solve these problems, the system and the exchange of information about the links between systems should define standards. IEC (International Electrotechnical Commission) power to solve these problems in the field of the Common Information Model (Common Information Model, CIM) standard (IEC61970, IEC61968) is defined as the transmission and distribution system integration and standardization for the exchange of information. In this paper, standardized system for building CIM-based distribution automation system should describe the process of building. In addition, the process of establishing a common information model needed (CIM) defined and associated services for a defined set of models is proposed in the standardization process.

Design of an Ultrasmall Flexible-endoscope Illumination Optical System with Bat-wing Light Distribution

  • Ju-Yeop Yim;Chul-Woo Park;Mee-Suk Jung
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.755-760
    • /
    • 2023
  • In this paper, an illumination optical system that can mitigate the saturation phenomenon in the center of an image (caused by the typical flexible-endoscope illumination system using LEDs with Lambertian light distribution) is designed. When an LED with Lambertian light distribution is used as a light source, the amount of light in the center of the endoscopic illumination system is relatively high, compared to the periphery, causing saturation in the image. Since this phenomenon causes difficulty in detecting the patient's lesion, it is necessary to find a lighting-system design that can alleviate the saturation phenomenon. Therefore, in this paper a lighting system with bat-wing light distribution, which can lower the intensity at the center and secure the maximum amount of light at the maximum light distribution angle, is designed. In addition, to check the performance of the designed lighting system, a simulation of illumination and luminance is conducted for a system using a common aspherical lens with otherwise the same components. As a result, it is confirmed that the lighting system designed in this paper effectively reduces the luminance value at the center and secures more luminance values at the periphery than the familiar lighting system.

A Study on the Problem and Improvement of the Distribution System of Pharmaceuticals in Korea

  • Su, Shuai;Yun, Ye-Sol
    • The Journal of Industrial Distribution & Business
    • /
    • v.3 no.1
    • /
    • pp.25-29
    • /
    • 2012
  • The purpose of this study is to examine the development of the pharmaceutical distribution industry. The pharmaceutical industry is are expected to suffer a heavy blow when the Free Trade Agreement (FTA) is introduced, despite its best efforts. Therefore, adequate solutions must be found. Section II introduces the Korean pharmaceutical distribution system and its current situation; Section III explores the distribution system's strengths and weaknesses. Section IV, identifies the problem and possible solutions for the Korean pharmaceutical distribution system; Section V summarizes and concludes this paper and acknowledges its limitations. Finally, this paper has a clear limitation. The lack of objective information and scientific analysis due to the data being based on interviews with company representatives is its most significant shortcoming. However, it offers implications for new directions for future research.

  • PDF

Design Of Air-Distribution System in a Duct (취출구를 가진 덕트의 공기분배장치 설계)

  • Kang, Hyung-Seon;Cho, Byung-Ki;Koh, Young-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.954-960
    • /
    • 2007
  • The purpose of this paper is to obtain design method of air-distribution system. Air-distribution system is composed of blower, duct, diffusers and measuring equipment. The air-flow rate from each diffuser is not equal. The air-flow rate is calculated with the combined equations which are Bernoulli's equation, continuity equation and minor loss equations. Inlet condition and outlet condition are adapted in each duct system. Then square difference between function of maximum air-flow rate and minimum air-flow rate is used as an object function. Area of diffuser and velocity are established as constraints. To minimize the object function, the optimization method is used. After optimization the design variables are selected under satisfaction of constraints. The air-distribution system is calculated again with the result of optimized design variable. It is shown that the air-distribution system has the equal air-flow rate from diffusers.

Application of Directional Over Current Protection Schemes Considering the Fault Characteristics in the Distribution System with Dispersed Generation (분산전원이 연계된 배전계통의 고장특성을 고려한 방향성 보호계전 방식 적용 연구)

  • Jung, Won-Wook;Lee, Hak-Ju;Kwon, Seong-Chul;Chae, Woo-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.97-107
    • /
    • 2010
  • Penetration of distributed generator(DG) to power distribution system can cause malfunction of existing protection schemes. Because grid interconnected DG can contribute fault currents and make bidirectional current flows on the system, fault contributions from DG can cause an interference of protection relay operation. Therefore, over current protection device of the distribution system with DGs need directional protection schemes. In this paper, improved directional protection algorithms are proposed for the distribution system with DG considering their fault characteristics. And than, these directional protection algorithms are tested and validated in various fault conditions. From the simulation results, it can be seen that the proposed directional protection algorithms are practically efficient for the radial distribution system with DG.

On the Analysis of Container Physical Distribution System in Pusan Port (부산항 컨테이너 물류 시스템 분석에 관하여)

  • Park, Chang-Ho;Lee, Cheol-Yeong
    • Journal of Korean Port Research
    • /
    • v.5 no.1
    • /
    • pp.55-69
    • /
    • 1991
  • A Container terminal is a physical link between the ocean and land modes of transport and a major component of the container physical distribution system. A number of projects to increase terminal productivity in the world were found to be tied directly to increasing the efficiency of the intermodal activities, that is, to improving the physical distribution process. This is an indication that the productivity of container terminal is being considered withing a system prospective. The purpose of this study is to establish a model of the container physical distribution system for Pusan port linked with 4 sub-systems including Navigational aids system, Cargo handling/transfer/storage system on dock, Off-dock CY system and In-land transport connection system. and to analyze the system. From this analysis, we found that the system had three bottlenecks on the container physical distribution process in Pusan port : a) cargo handling b) storage and c) inland transport, and showed a way to improve the system.

  • PDF