• Title/Summary/Keyword: distribution System

Search Result 15,410, Processing Time 0.047 seconds

Visualization of oxygen distribution on leaf surfaces using VisiSens oxygen planar optode system (VisiSens 산소 평면광 센서 시스템을 이용한 식물 잎 표면의 산소분포 가시화)

  • Hwang, BaeGeun;Kim, HyeJeong;Lee, SangJoon
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.1
    • /
    • pp.51-56
    • /
    • 2016
  • Oxygen is a key factor in aerobic reactions and most biological activities. Visualization of oxygen distribution of a chemical process or biological system has been a very challenging object despite of its significance and potential impact. To monitor and visualize the spatial distribution of oxygen concentration, various techniques such as electro-chemical probe, polarographic electrode, LIF(laser-induced fluorescence) and so on have been introduced. Oxygen planar optode which utilizes the oxygen quenching of fluorescence light is one of the currently available methods for time-resolved visualization of oxygen distribution on a planar surface. In this study, we utilized VisiSens oxygen planar optode system to visualize the spatial distribution of oxygen concentration on leaves of Korean azalea. As a result, temporal variation of oxygen concentration distribution caused by respiratory activity of the leaf could be quantitatively monitored.

Relationship between ICAC EP-7 and %RMS, Standards for Gas Flow Uniformity inside Electrostatic Precipitators (전기집진기 내부 유동 균일도 평가 기준인 ICAC EP-7과 %RMS 간 상관관계)

  • Shin, Wan-Ho;Hong, Won-Seok;Song, Dong-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.234-240
    • /
    • 2010
  • Gas flow uniformity is an important factor to guarantee particle removal performance of electrostatic precipitators (EP), and the gas flow uniformity is evaluated by a fraction of standard deviation to the mean of gas flow distribution (%RMS) or a technical standard, ICAC EP-7, provided by The Institute of Clean Air Companies. In this study, relationship between the ICAC EP-7 and %RMS in evaluation of gas flow uniformity was investigated in terms of flow velocity. The maximum values of %RMS for gas velocity distribution of normal distribution has been obtained, and the maximum values of %RMS with gas velocity distribution satisfying ICAC EP-7 standards were also evaluated. With gas flow distribution obtained from CFD analysis and physical model test of real EP, %RMS values were calculated and it was tested if those gas flow distribution satisfy the criteria specified in ICAC EP-7. The %RMS values satisfying criteria of ICAC have been appeared to have similar values with %RMS values calculated with normal distribution of gas velocities.

Development of specific organ-targeting drug delivery system 1

  • Kim, Chong-Kook;Jeong, Eun-Ju;Yang, Ji-Sun;Kim, Seung-Hwan;Kim, Yang-Bae
    • Archives of Pharmacal Research
    • /
    • v.8 no.3
    • /
    • pp.159-168
    • /
    • 1985
  • In attempt to develop a drug delivery system using serum albumin microspheres, bovine serum albumin microspheres containing antitumor agent, cytarabine, were prepared. The shape, surface characteristics, size distribution, behavior of in vitro distribution, drug release behaior, and degradation of albumin microspheres in animal liver tissue homogenate and proteolytic enzyme were investigated. The shape of albumin microspheres was spherical and the surface was smooth and compact. The size distribution of the albumin microspheres was affected by dispersion forces during emulsification and albumin concentration. Distribution of albumin mirospheres after intravenous administration in rabbit was achieved immediately. In vitro, albumin microsphere matrix was so hard that it retained most of cytarabine except initial burst during the first 10 minutes, and the level of drug release during the initial burst was affected by heating temperature, drug/albumin concentration ratio and size distribution. After drug release test, the morphology of albumin micropheres was not changed. Albumin microsphere matrix was degraded by the rabbit liver tissue homogenate and proteolytic enzyme. The degree of degradation was affected by heating temperature.

  • PDF

[Review] A Study on the Change of the Payments System : Focusing on the Strategies of Distribution Companies and Fin-tech Companies

  • So Hyung KIM
    • Journal of Distribution Science
    • /
    • v.21 no.5
    • /
    • pp.113-120
    • /
    • 2023
  • Purpose: The purpose of the study is to examine how payment systems for traditional distribution channels pursue changes and how they collaborate in-depth with fintech companies. This study examines the changing payment system through the strategic partnership between distribution companies and fintech companies. Research Design, Data and Methodology: The study conducted research using a variety of secondary materials and existing literature and also utilized the interview method. More specific and in-depth research is conducted through various literature studies and secondary data. Findings and Results: The findings of the study are as follows. First, distributors have occasionally directly adopted simple payment systems due to changes in payment systems as a result of online advances. Second, distributors were found to collaborate with fintech companies when not directly using simple payment. Conclusions: Such maneuvers by distributors are aimed at first, providing convenience and simplicity for consumers. Second, developing the ability to apply big data for accumulating consumer information and third, producing a customer lock-in effect by reducing the fees charged for existing payment services. The present study will provide many domestic and international distributors with a new perspective and practical implications in terms of the distribution and finance industries.

Design of the Reconfigurable Load Distribution Control Allocator

  • Yang, Inseok;Kang, Myungsoo;Sung, Jaemin;Kim, Chong-Sup;Cho, Inje
    • International Journal of Aerospace System Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • This paper proposes the load distribution control allocation technique. The proposed method is designed by combining a conventional control allocation method with load distribution ability in order to reduce the stress acting on ailerons. By designing the weighting matrix as a function of the load distribution rule, the optimal deflection angles of each surface to satisfy both control goal and load distribution can be achieved. Moreover, rule based fault-tolerant control technique is also proposed. The rules are generated by considering both dominant control surfaces and the ratio of load distribution among surfaces. The performance of the proposed method is evaluated through numerical simulations.

Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines (병행 배전선로에서의 통신선 유도전압 계산)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Seong-Heon;Kim, Seong-Arm;Weon, Bong-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

Automatic Distribution System using a Micro Controller Unit (MCU를 이용한 자동 분류 시스템)

  • Kim, Tae-Hyoung;Lee, Chan-Jae;Kwon, Jae-Hyoung;Kim, Young-Seong;Kim, Yik-Hyoun;Tak, Bo-Mi;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.81
    • /
    • pp.35-41
    • /
    • 2007
  • According as the industry develops recently, the import and export freight amount is increasing sharply, but physical distribution processing equipment ability had achieved conveyance, surge and setup of physical distribution by human's labor ability. But, inefficiency is indicated in operation of product line and warehouse or physical distribution storage equipment because is ceilinged the processing physical distribution amount and the efficiency in physical distribution processing by these labor ability.

Verification of Underground Distribution Line Modeling with Field Test (실증시험을 통한 지중배전선로 모델링 기법 검증 연구)

  • Yun, Chang-Sub;Lee, Jae-Bong;Kim, Byong-Suk;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2091-2097
    • /
    • 2007
  • This paper described the verification of modeling technique of underground distribution from comparison between field test and simulation. It needs more exact transient phenomenon analysis model to establish lightning protection of underground distribution line. Although, there were a lot of transient phenomenon researches, nobody could has verified the confidence of modeling from field tests in interior until now. So, simulation model verified field test is needed to analyse transient phenomenon of underground distribution system. The examination must be accomplished in many different condition before suggesting these verified analysis model. In this paper, the conditions were examined and the various data results on the different line composition was compared with the EMTP simulation, when the lightning impulse test was accomplished at underground distribution line. Also the value between field test and simulation was very closed and the method of modeling has demonstrated confidence, when the method is used to analyse domestic transient phenomenon of underground distribution.

Development of Web-based Simulator for Supply Chain Network with Reconfigurable Manufacturing System and Multi-layered Distribution Center (재구성가능 제조시스템과 다계층 구조를 가지는 분배센터로 구성된 공급사슬망을 위한 웹기반 시뮬레이터 개발)

  • Seo, Min-Seok;Lim, Dae-Eun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.37 no.4
    • /
    • pp.279-288
    • /
    • 2011
  • The past researches focused on the supply chain network that consists of factories, distribution centers and retailers for single product type. This research is required because the factory for single product type is advanced to reconfigurable type in order to produce various products, according to customers' various purchase forms and time. This research is also required because in the past researches, the material flows from factories to distribution centers and from distribution centers to retailers, but recently, there are material flows between distribution centers. The supply chain network in this research consists of reconfigurable manufacturing system, multi-layered distribution centers, and retailers. A simulator is developed to analyze the material flow on the supply chain network. The developed simulator is web-based designed by using Java Server Page and MS-SQL, so as to maximize the convenience for users.

The Optimal Spare Level of a Weapon System having Phase-type Repair Time (Phase-type 수리시간을 갖는 무기체계의 적정예비품수 결정)

  • Yoon, Hyouk;Lee, Sang-Jin
    • Korean Management Science Review
    • /
    • v.26 no.3
    • /
    • pp.145-156
    • /
    • 2009
  • The probability distribution of the repair process should be determined to choose the optimal spare level of a weapon system with a queueing model. Though most weapon systems have a multi-step repair process, previous studies use the exponential distribution for the multi-step repair process. But the PH distribution is more appropriate for this case. We utilize the PH distribution on a queueing model and solve it with MGM(Matrix Geometric Method). We derive the optimal spare level using the PH distribution and show the difference of results between the PH and exponential distribution.