References
- Chen, J., Kim, H. D. and Kim, K. C., 2012, "Quantitative visualization of oxygen transfer in micro-channel using micro-LIF technique", J. Korean Soc. Vis., Vol.10(1), pp.34-39. https://doi.org/10.5407/JKSV.2011.10.1.034
- Lee, J. S., Kim, E. S., An, S. U., Kim, J., Kim, J. K., Khang, S. H. and Kang, D. J., 2013, "Two-dimensional oxygen distribution in a surface sediment layer measured using an RGB color ratiometric oxygen planar optode", Ocean Polar Res., Vol.35(3), pp.229-237. https://doi.org/10.4217/OPR.2013.35.3.229
- Glud, R. N., Ramsing, N. B., Gundersen, J. K. and Klimant, I., 1996, "Planar optrodes: a new tool for fine scale measurements of two-dimensional O2 distribution in benthic communities", Mar. Ecol. Prog. Ser., Vol.140, pp.217-226. https://doi.org/10.3354/meps140217
- Holst, G., Kohls, O., Klimant, I., Konig, B., Kuhl, M. and Richter, T., 1998, "A modular luminescence lifetime imgaing system for mapping oxygen distribution in biological samples. Sensor Actuat. B-Chem. Vol.51(1), pp.163-170. https://doi.org/10.1016/S0925-4005(98)00232-9
- Song, D. H., Kim, H. D. and Kim, K. C., 2011, "Quantitative visualization of dissolved oxygen concentration field in micro flows using PtOEP/PS membrane", J. Korean Soc. Vis., Vol.9(1), pp.36-41. https://doi.org/10.5407/JKSV.2011.9.1.036
- Glud, R. N., Kuhl, M., Kohls, O.and Ramsing, N. B., 1999, "Heterogeneity of oxygen production and consumption in a photosynthetic microbial mat as studied by planar optodes", J. Phycol., Vol.35(2), pp.270-279. https://doi.org/10.1046/j.1529-8817.1999.3520270.x
- Philip, T. W. and, Steve, R. D., 2001, "Laserinduced fluorescence studies of oxygen transfer across unsheared flat and wavy air-water interfaces", Ind. Eng. Chem. Res., Vol. 40, pp. 1985-1995. https://doi.org/10.1021/ie000321j
- Dani, A., Guiraud, P. and Cockx, A., 2007, "Local measurement of oxygen transfer around a single bubble by planar laser induced fluorescence", Chem. Eng. Sci., Vol.62, pp.7245-7252. https://doi.org/10.1016/j.ces.2007.08.047
- Francois, N., Dietrich, N., Guiraud, P., and Cockx, A., 2011, "Direct measurement of mass transfer around a single bubble by micro-PLIFI", Chem. Eng. Sci., Vol.66, pp.3328-3338. https://doi.org/10.1016/j.ces.2011.01.049
- Tschiersch, H., Liebsch, G., Borisjuk, L., Stangelmayer, A. and Rolletschek, H., 2012, "An imaging method for oxygen distribution, respiration and photosynthesis at a microscopic level of resolution", New Phytol., Vol.196(3), pp.926-936. https://doi.org/10.1111/j.1469-8137.2012.04295.x
- Zhu, F., Baker, D., Skommer, J., Sewell, M. and Wlodkowic, D., 2015, "Real-time 2D visualization of metabolic activities in zebrafish embryos using a microfluidic technology", Cytome. Part A, Vol.87(5), pp.446-450. https://doi.org/10.1002/cyto.a.22662
- Tschiersch, H., Borisjuk, L., Rutten, T. and Rolletschek, H., 2011, "Gradients of seed photosynthesis and its role for oxygen balancing", Biosys., Vol.103(2), pp.302-308. https://doi.org/10.1016/j.biosystems.2010.08.007
- Meier, J. K., Prantl, L., Muller, S., Moralis, A., Liebsch, G. and Gosau, M., 2012, "Simple, fast and reliable perfusion monitoring of microvascular flaps", Clin. Hemorh. Microcirc., Vol.50(1-2), pp.13-24.
- Warnat, J., Liebsch, G., Stoerr, E. M., Brawanski, A. and Woertgen, C., 2008, "Simultaneous imaging of cortical partial oxygen pressure and anatomic structures using a transparent optical sensor foil", J. Neurosurg. Anesthesiol., Vol.20(2), pp.116-123. https://doi.org/10.1097/ANA.0b013e318160545e