• Title/Summary/Keyword: distribution System

Search Result 15,350, Processing Time 0.054 seconds

Analysis of electric characteristics for extension power supply between different grounding railway distribution system (접지방식이 상이한 철도배전계통의 연장급전을 위한 전기적 특성분석)

  • Jung, Ho-Sung;Han, Moon-Seob;Lee, Chang-Mu;Kwon, Sam-Young;Park, Hyeun-Jun
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.736-741
    • /
    • 2005
  • This paper presents electric characteristics analysis and safe configuration for extension power supply between existent 6.6kV ungrounded distribution system and establishment and improvement 22.9kV direct grounding distribution system. For this, we model 6.6kV ungrounded and 22.9kV direct grounding distribution system of urban underground, ground region. and rural electrical, unelectrical region using PSCAD/EMTDC and analyze voltage drop, charging current, ground and short fault through simulation. To analyze electric characteristics of extension power supply, we simulate extension power supply of overhead line of 6.6kV ungrounded system and underground line of 22.9kV direct grounding system of rural electrical region and propose operation condition for safe extension power supply through result of analysis. Characteristics of voltage drop, charging current, ground and short fault appear almost similarly with electrical characteristic of direct power supply. However, because unbalance of phases may cause relay's malfunction of ungrounded system and ground fault current of direct grounding system may demage facilities of ungrounded system, we propose safe system configuration such as impedance grounding system of neutral point.

  • PDF

Design and Implementation of FEP for Interfacing of Distributed Power Generation (분산전원 연계용 데이터처리장치(FEP)의 설계 및 구현)

  • Lee, Sung-Woo;Ha, Bok-Nam;Seo, In-Yong
    • Journal of Energy Engineering
    • /
    • v.18 no.3
    • /
    • pp.147-155
    • /
    • 2009
  • Demand for distributed source by new and renewable energy has been gradually increasing recently. For the characteristics of distributed generation, distributed source is located near the distribution system and customers' buildings and can be operated in standalone mode or in interface mode with distribution system. When the distributed sources are interfaced with distribution system, the standard for interfacing distributed source with existing distribution system and operation manual should be updated with revisions in order to manage the distributed source effectively and operate the distribution system stably because how to operate the interfaced system is different from that of existing distribution system. In this paper, the FEP(Front End Processor) using the international standard protocol IEC-60870 for interfacing with distributed resources was designed. The designed system was verified via the test result using main control system for distributed generation and RTU(Remote Terminal Unit) for interface with distributed power generating.

Development and Performance Evaluation of Radial Exhaust Multi-port System for Real-time Particle Size Distribution Measurement (실시간 입자분포 측정을 위한 Radial Exhaust Multi-port System의 개발 및 성능평가)

  • Lee, Hong Ku;Lee, Yang-Woo;Jeon, Ki Soo;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.133-137
    • /
    • 2013
  • Measuring particle size distribution is one of the primary concerns in aerosol studies. For a nano-particle size distribution measurement, many scientists use a combination of a differential mobility analyzer (DMA) and a condensation particle counter (CPC) system, which is a called scanning mobility particle sizer (SMPS). Although it has a very high particle size resolution, some issues still remain. These problems include residence time between a DMA and a CPC, discontinuity of a CPC, and disturbance due to long scanning time during the precise measurement of particles. In particular, long scanning time is not adequate for measuring particle size distribution since the particle concentration is changing during the measurement. In this study, we developed radial exhaust multi-port system (REM-system) with no scanning time and high resolution to measure real-time particle size distribution. As a result of the REM-system performed using mono-disperse particle, it is expected that this system will be suitable for measuring continuously changing aerosol. If the counting efficiency of multi-condensation particle counter (M-CPC) and data inversion matrix are completed, REM-system will be a very adequate system for unsteady aerosol, which changes for SMPS scanning time.

A Study on Economic Evaluation Modeling of MVDC Distribution System for Hosting Capacity of PV System (태양광전원 수용을 위한 MVDC 배전망의 경제성평가 모델링에 관한 연구)

  • Lee, Hu-Dong;Kim, Ki-Young;Kim, Mi-Sung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.1-12
    • /
    • 2021
  • Technologies for an MVDC(medium voltage direct current) distribution system are being considered as an effective alternative to overcome the interconnection delay issues of PV systems. However, the implementation of a DC distribution system might lead to economic problems because of the development of DC devices. Therefore, this paper deals with the scale of a PV plant based on its capacity and proposes hosting-capacity models for PV systems to establish a network to evaluate the feasibility of an MVDC distribution system. The proposed models can be classified as AC and DC distribution systems by the power-supply method. PV systems with hundreds of MW, dozens of MW, and a few MW can be categorized as large-scale, medium-scale, and small-scale models, respectively. This paper also performed modeling for an economic evaluation of MVDC distribution system by considering both the cost of AC and DC network construction, converter replacement, operation, etc. The profit was composed of the SMP and REC rate of a PV plant. A simulation for economic evaluation was done for the MVDC distribution system using the present worth and equal-principal costs repayment method. The results confirmed that the proposed model is a useful tool to evaluate economic issues of a DC distribution system.

A Study on the Sizing System for Middle and Highschool Girls' Uniforms (여자 중고등학생 교복 치수 설정에 관한 연구)

  • Hyun, Eun-Kyong;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.11 no.4
    • /
    • pp.602-613
    • /
    • 2009
  • This study aims to improve the fit of middle and high school girls' uniforms. This study researched on the sizing system reflecting their body figures. The results are as follows. First, to classify the middle and high school girls' figures, factor analysis, and cluster analysis were conducted. 4 factors were extracted for upper body of the middle school girls, and 5 factors were extracted for the highschool girls. For the lower body, 3 factors were extracted for both the middle and high school girls. The middle school girls were then divided into 4 groups for the upper body and 4 groups for the lower body. The high school girls were divided into 4 upper and lower body groups. Third, KS size intervals were used for frequency distribution of height and bust for the bodice, height and waist for the lower body. Sizing system of the uniform company and the frequency distribution of sizes were compared. As a result, sizing system of the uniform company and the frequency distribution overlapped very little. Fourth, sizing system considering body type distribution and high frequency distribution of sizes was suggested. As a result when 6 sizes were suggested 30% of the population was covered, and when 11 sizes were suggested 55% of the population was covered.

Implementation of a Photovoltaic System Simulator for Interconnecting with Bipolar ±750V DC distribution Grid (바이폴 ±750 직류 배전망 연계용 태양광 발전 시뮬레이터 구현)

  • Kim, Tae-Hoon;Kim, Seok-Woong;Cho, Jin-Tae;Kim, Ju-Yong;Jung, Jae-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1800-1805
    • /
    • 2016
  • The micro-grid designed as bipolar ${\pm}750V$ low-voltage DC power distribution system demonstrated by KEPRI, demands interconnection of a number of small decentralized power source including variable renewable generator. Therefore, variable researches for the influence of interconnection with the bipolar typed DC grid and these variable power sources are required for superior quality of power distribution. Renewable power generation simulators for the bipolar ${\pm}750V$ low-voltage DC power distribution system are necessary for such researches. In this paper, we carry out a research on the photovoltaic simulator that be actually able to interconnect with a bipolar ${\pm}750V$ low-voltage micro-grid. Simulator for this research is not only able to simulate photovoltaic generation according to weather informations and PV modules characteristics, but also contribute to stabilization of bipolar ${\pm}750V$ low-voltage of the system. Therefore, the simulator was designed to develop a system that can situationally respond to variable control algorithms such as the MPPT control, droop control, EMS power control, etc.

Future New Distribution System with Low voltage and Mass Capacity using HTS equipments (초전도기기를 적용한 미래 저압대용량 신 배전계통)

  • Yoon Jae Young;Kim Jong Yul;Lee Seung Ryul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.37-41
    • /
    • 2005
  • This paper describes the construction scheme of new distribution system using HTS(High Temperature Superconducting) power equipments such as cable, transformer and FCL(fault current limiter). At present, one of the most serious problems in distribution power system, especially for metropolitan complex city, is to obtain the ROW for cable line routes, space for downtown substations and satisfy the environmental protection caused by NIMBY phenomena. Unfortunately, it is expected that this situation will get more and more worse. As the HTS technology to apply in power system Is developed, HTS cable utilizing mass-capacity characteristic can be a useful countermeasure to overcome this problem. This paper describes the application methodology of 22.9kV HTS cable with low-voltage, mass-capacity characteristics replacing the 154kV conventional cable. By applying 22.9kV HTS cable, the HTS transformer with higher capacity for the reduction of space and transformer numbers of downtown substation is necessary. Also, if the leakage Impedance of HTS transformer is same as or lower than that of conventional transformer, the fault current of 22.9kV bus will increase because the HTS transformer capacity is larger than that of the conventional transformer. This means the parallel application of HTS-FCL to reduce the fault current in addition to the HTS cable and transformer can be necessary. With the basic construction scheme of new distribution system, this paper describes the future study points to realize this new distribution system using HTS equipments.

A Study on Momentary Voltage Variations and Fault Analysis in the Power Distribution System with Congeration Facilities (COGN). (열병합발전설비가 연계된 배전계통 순시전압변동 및 사고해석에 관한 연구)

  • Jung, Seong-Kyo;Choi, Joon-Ho;Kim, Dae-Won;Kim, Jae-Chul;Son, Hag-Sig;Kim, Yun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1192-1194
    • /
    • 1999
  • Recently, there has been growing interest in utilizing cogeneration(COGN) system which has high energy efficiency due to the lacking of energy resource, but insertion of cogeneration system into existing power distribution system can cause several problems such as voltage variations, reenergizing of feeder isolated by fault, increasing fault current because of reverse power of COGN. Also these problems increase the complexity of control, protection, and maintenance of power distribution systems. Hence, some problems according to COGN interconnection operation to power distribution system must be taken into account so that operation and security of power distribution system is not disturbed. This paper deals with momentary voltage variations and fault analysis caused by interconnection operation of COGN.

  • PDF

A Study on the New Scheme for South Korea's Artwork Authenticity With a Review of the Overseas Art Distribution Dispute Setting System (해외 미술품 유통분쟁 해결제도를 통해 살펴본 국내 미술품 진본성 확보방안)

  • Rim, Sung Ryun;Byun, Seung Hyuk
    • Journal of Arbitration Studies
    • /
    • v.30 no.1
    • /
    • pp.199-215
    • /
    • 2020
  • Compared to Korea's recently expanding art distribution market, the difficulty of securing the authenticity of art is hindering the healthy development and growth of the market. In this regard, the current situation of the emotional system in the UK and France's art distribution process are examined as excellent cases in foreign countries. In the UK, there is a full autonomous appraisal system by art experts without state intervention. In France, the judiciary and the administration of art have an appraisal system for art works, so the appraisal work has reliability and objectivity. Through the above system, this study suggests measures to strengthen transparency in art trade and to break unfair practices in order to secure the authenticity of the domestic art distribution market. In addition, this study proposes the establishment of a professional appraisal system and the improvement of administrative law regulations to explore the possibility of ensuring fairness through mediation through the example of an international arbitration body.

A Study on the Sizing System for Highschool Girls' Uniforms (여자 고등학생 교복 치수 설정에 관한 연구)

  • Hyun, Eun-Kyung;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.11 no.3
    • /
    • pp.445-452
    • /
    • 2009
  • This study aims to improve the fit of high school girls' uniforms. This study researched on the fit of the recent high school girls' uniforms and developed a sizing system that adequately reflects their body figures. The results are as follows. First, the research showed that over 50% of the highschool girls wore their blouses too tight, whereas over 60% of the girls wore skirts that were appropriately fitted. Second, to classify the high school girls' figures, factor analysis and cluster analysis were conducted. 5 factors were extracted for upper body and 3 factors for the lower body. The girls were then divided into 3 groups for the upper body and 4 groups for the lower body. Third, KS size intervals were used for frequency distribution of height and bust for the bodice, height and waist for the lower body. Sizing system of the uniform company and the frequency distribution of sizes were compared. As a result, sizing system of the uniform company and the frequency distribution slightly overlapped. Fourth, sizing system considering body type distribution and high frequency distribution section of sizes was suggested. As a result, for the upper body, when 6 sizes were suggested, 43.9% of the population was covered and when 11 sizes were suggested, 58.3% was covered. For the lower body, when 6 sizes were suggested, 32.2% was covered, and when 11 sizes were suggested 58.9% of the population was covered.