• Title/Summary/Keyword: distilled water

Search Result 2,421, Processing Time 0.029 seconds

Characteristics of Ginseng Extract and Its Effects on Sensory Properties of Pork Sausage (인삼 추출물의 사포닌 조성 특성과 추출물 첨가가 포크소시지 관능 특성에 미치는 영향)

  • Park, Kyoung-Mi;Hwang, In-Ho
    • Food Science of Animal Resources
    • /
    • v.26 no.4
    • /
    • pp.418-425
    • /
    • 2006
  • This study was conducted to evaluate extraction properties of crude saponin and ginsenosides, and their effects on sensory properties of emulsified pork sausage. Non-dried ginseng root was boiled in 0 (e.g., 100% distilled water), 20, 40, 60, 80 or 100% ethanol, and powdered by a freezing dry method. Weight of dried powder for the 0% ethanol extraction was 20% of initial non-dried ginseng weight, while $20{\sim}80%$ and 100% ethanol extractions resulted in approximately 15 and 10% of their initial weights, respectively. On the other hand, crude saponin content in the dried powder was linearly increased for a higher ethanol content where 100% ethanol extraction resulted in 123.52 mg/g. LC/MS analysis of crude saponin for quantifying ginsenosides showed that Rb1, Rb2 and Rc were significantly (p<0.05) higher levels for both 80 and 100% ethanol extractions. In the case of Rg1 ginsenoside, 60, 80 and 100% ethanol extractions resulted in significantly (p<0.05) higher levels. Emulsified pork sausages containing 0, 1 or 2% ginseng extracts were smoked or non-smoked and their sensory characteristics and preference were evaluated. Smoking process significantly (p<0.05) decreased juiciness and tenderness, but the treatment significantly (p<0.05) improved flavor and consumer preference. It was particularly noticed that a 2% addition of ginseng extract prevented the adverse effects of smoking process on juiciness and tenderness while the 2% addition significantly (p<0.05) improved consumer preference. The current results implied that addition of ginseng extract in emulsified pork sausage could improve sensory quality.

Effects of laser-irradiated dentin on shear bond strength of composite resin (레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향)

  • Kim, Sung-Sook;Park, Jong-Il;Lee, Jae-In;Kim, Gye-Sun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.520-527
    • /
    • 2008
  • Purpose: This study was conducted to evaluate the shear bond strength of composite resin to dentin when etched with laser instead of phosphoric acid. Material and methods: Recently extracted forty molars, completely free of dental caries, were embedded into acrylic resin. After exposing dentin with diamond saw, teeth surface were polished with a series of SiC paper. The teeth were divided into four groups composed of 10 specimens each; 1) no surface treated group as a control 2) acid-etched with 35%-phosphoric acid 3) Er:YAG laser treated 4) Er,Cr:YSGG laser treated. A dentin bonding agent (Adapter Single Bond2, 3M/ESPE) was applied to the specimens and then transparent plastic tubes (3 mm of height and diameter) were placed on each dentin. The composite resin was inserted into the tubes and cured. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours and the shear bond strength was measured using a universal testing machine (Z020, Zwick, Germany). The data of tensile bond strength were statistically analyzed by one-way ANOVA and Duncan's test at ${\alpha}$= 0.05. Results: The bond strengths of Er:YAG laser-treated group was $3.98{\pm}0.88$ MPa and Er,Cr:YSGG laser-treated group showed $3.70{\pm}1.55$ MPa. There were no significant differences between two laser groups. The control group showed the lowest bond strength, $1.52{\pm}0.42$ MPa and the highest shear bond strength was presented in acid-etched group, $7.10{\pm}1.86$ MPa (P < .05). Conclusion: Laser-etched group exhibited significantly higer bond strength than that of control group, while still weaker than that of the phosphoric acid-etched group.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.

Application of 'Sponge Model' with Disinfectants for the Inhibition of Listeria monocytogenes (Listeria monocytogenes의 증식억제를 위한 살균제 'Sponge model'의 응용)

  • LEE Myung-Suk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.5
    • /
    • pp.595-602
    • /
    • 1996
  • The antimicrobial effects of two disinfectants commonly used in food industry on Listeria monocytogenes ATCC 15313 were studied. The two disinfectants tested were commercial benzalkonium chloride (BAC) and sodium hypochlorite (NaOCl). Their effects were studied on cells suspended in disinfectants (in vitro) and in the sponge model with the disinfectants (in vivo). When cells were exposed to $0\~0.1\%$ BAC and $0\~150\;ppm$ NaOCL for 20 minutes, BAC and NaOCl concentration more than $0.25\%$ and 100 ppm showed the antimicrobial effects respectively. This organism decreased rapidly during the first $0.5\~1$ minute followed by a slower decrease during the rest of the exposure time. Fifteen ml of cell solution $(about\;10^7\;CFU/ml\;in\;the\;TSB)$ was mixed with 15 ml of disinfectants in the sponge $(6.0{\times}4.0{\times}4.0cm)$, BAC and NaOCl concentration more than $0.1\%$ and 300 ppm showed the antimicrobial effects, and at $0.25\%$ and 800 ppm diminished in cell numbers 3-log cycles during the first 20 minutes. In the case of sponge model, 15 ml of cell solution and 15 ml of disinfectants $(0.25\%\;of\;BAC,\;800\;ppm\;of\;NaOCl)$ were suspended in the sponge during 20 minutes, washing with 200 ml of sterilized distilled water, and this sponge was transfered in the 100 ml TBS, and then incubated at various temperature. The cells were increased about 1-log cycle during 24 hrs at $5\~15^{\circ}C$. And the others temperature, the cells growth was in proporation to storage tepmerature and the cells were about $10^9\;CFU/ml$ after $1\~3$ days incubations.

  • PDF

Viscosity and Wettability of Carboxymethylcellulose(CMC) solutions and Artificial Saliva (Carboxymethylcellulose(CMC) 용액과 인공 타액의 점도와 습윤성)

  • Park, Moon-Soo;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 2007
  • Destruction of oral soft and hard tissues and resulting problems seriously affect the life quality of xerostomic patients. Although artificial saliva is the only regimen for xerostomic patients with totally abolished salivary glands, currently available artificial salivas give restricted satisfaction to patients. The purpose of this study was to contribute to the development of ideal artificial saliva through comparing viscosity and wettability between CMC solutions and human saliva. Commercially-available CMC is dissolved in simulated salivary buffer (SSB) and distilled deionized water (DDW). Various properties of human whole saliva, human glandular saliva, and a CMC-based saliva substitutes known as Salivart and Moi-Stir were compared with those of CMC solutions. Viscosity was measured with a cone-and-plate digital viscometer at six different shear rates, while wettability on acrylic resin and Co-Cr alloy was determined by the contact angle. The obtained results were as follows: 1. The viscosity of CMC solutions was proportional to CMC concentration, with 0.5% CMC solution displaying similar viscosity to stimulated whole saliva. Where as a decrease in contact angle was found with increasing CMC concentration. 2. The viscosity of human saliva was found to be inversely proportional to shear rate, a non-Newtonian (pseudoplastic) trait of biological fluids. The mean viscosity values at various shear rates increased as follows: stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 3. Contact angles of human saliva on the tested solid phases were inversely correlated with viscosity, namely decreasing in the order stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 4. Boiled CMC dissolved in SSB (CMC-SSB) had a lower viscosity than CMC-SSB (P < 0.01 at shear rate of $90s^{-1}$). 5. For human saliva, contact angles on acrylic resin were significantly lower than those on Co-Cr alloy (P < 0.01). 6. Comparing CMC solutions with human saliva, the contact angles between acrylic resin and human saliva solutions were significantly lower than those between acrylic resin and CMC solutions, including Salivart and Moi-Stir (P <0.01). The effectiveness of CMC solutions in terms of their rheological properties was objectively confirmed, indicating a vital role for CMC in the development of effective salivary substitutes.

Leaching Properties on Waste Form with Garnet Structure (석류석 구조를 가진 고화체의 용출 특성)

  • Chae Soo-Chun;Jang Young-Nam;Bae In-Kook;Ryu Kyung-Won;Ioudintseva T.S.;Yudintsev S.V.
    • Economic and Environmental Geology
    • /
    • v.39 no.2 s.177
    • /
    • pp.181-190
    • /
    • 2006
  • Garnet has been suggested as one of the most promising material for the immobilization of radionuclide in high level waste. But data on its chemical durability are sufficiently available. Accordingly, Gd and Ce garnets were synthesized as imitators for $Pu^{3+}\;and\;Pu^{4+}$ were synthesized, and their leaching rates, the parameters of the chemical durability were measured by changing the conditions. In distilled water, the ranges of leaching rates of Gd and Ce were $1.2{\times}10^{-4}{\sim}4.6{\times}10^{-6}g/m^2/day\;and\;7.5{\times}10^{-5}{\sim}1.8{\times}10^{-7}g/m^2/day$, respectively. A comparison with previous data suggests that the chemical durabilities of garnets synthesized from this study are superior to those of other waste forms. Additional leaching experiments were performed with 0.01M-HCl and 0.01M-NaOH solutions to see Gd and Ce leaching at acidic and alkalinity conditions. In 0.01 H-HCl solution, the ranges of leaching rates of Gd and Ce were $2.5{\times}10^{-1}{\sim}6.9{\times}10^{-3}g/m^2/day\;and\;3.7{\times}10^{-1}{\sim}3.1{\times}10^{-3}g/m^2/day$, respectively, while were $3.1{\times}10^{-4}{\sim}1.3{\times}10^{-6}g/m^2/day\;and\;1.8{\times}10^{-3}{\sim}0g/m^2/day$, respectively in 0.01M-NaOH solution. It is believed that leaching data can be used in understanding chemical durabilities of waste from garnets in acidic and alkaline conditions.

Immunoelectron Microscopic Study on the Paneth Cell of Rabbit after the Common Bile Duct Ligation (총담관결찰후 집토끼 Paneth세포의 변화에 대한 면역전자현미경적 연구)

  • Park, Kyung-Ho;Cho, Hwee-Dong;Yang, Nam-Gil;Ahn, E-Tay;Ko, Jeong-Sik;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.24 no.2
    • /
    • pp.78-92
    • /
    • 1994
  • Lysozyme has been reported to be present in the secretory granules of the Paneth cell, and lysozyme immunoreactivity has been detected by immunogold method in Paneth cells of the intestine of human, mouse and rat. The present study was aimed at clarifying the intracellular distribution and changes of the lysozyme immunoreactivity in rabbit Paneth cell after common bile duct ligation of rabbit, using the electron microscope immunogold technique. Healthy adult rabbits weighing about 2kg body weight were divided into normal and bile duct ligated groups. Common bile duct ligation was performed aseptically under ether anesthesia. Experimental animals were sacrificed on the 1st, the 3rd, the 5th, the 7th and the 14th day after the operation. Mucosal specimens from the intestinal gland of ileum were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde, followed by 1% osmium tetroxide, embedded in araldite mixture, cut with LKB-V ultratome. Ultrathin sections were placed on parlodion coated nickel grids (200mesh). The section-bearing grids were floated upside down on the added substance in a moist chamber at room temperature except for the primary antibody step, which was at $4^{\circ}C$. Sections were etched with a saturated solution of sodium m-periodate for 60min. After etching, sections were pretreated with 0.02M tris buffered saline (TBS), pH 8.4, with 1% bovine serum albumin (BSA, Sigma) for 60min, then treated polyclonal rabbit anti-human lysozyme (Dakipatts) diluted 1 : 50 in TBS with 0.1% BSA for 20hr. Subsequently, grids were incubated 60min in biotinylated goat anti rabbit IgG (Amersham) diluted 1 : 100 in TBS with 0.1% BSA. After this, sections were incubated 60min on streptavidin gold G10 (Amersham) diluted 1 : 50 in TBS with 0.1% BSA. After each step, the grids were briefly rinsed with TBS with 0.1% BSA. After the strepavidin gold step, the sections were jet washed with distilled water. Counterstain of the sections performed by uranyl acetate and lead citrate, and observed with JEM 100 CX II electron microscope. Observed results were as follow; 1. Secretory granules of mouse Paneth cells have a lysozyme immunoreactivity and also eosinophil leucocyte of rabbit applied for the positive-control stain, are well labeld with gold particles. 2. Normal rabbit Paneth cells have a lysozyme immunoreactivity restricted on the secretory granules. 3. Amount lysosomes containing myelin figures in the Paneth cells were significantly increased from 5th day after the common bile duct ligation. 4. Immunoreactivity of Paneth cell secretory granules were more activated on the 3rd day after the common bile duct ligation as compared with those of the normal animal. But the lysozyme immunoreactivity were decreased from the 5th day after the common bile duct ligation. 5. Considering the above finding, lysozyme contained Paneth cell are affected following of common bile duct ligation, whereas lysosomes containing myelin-figure do not exhibit any immunoreactive relationship with those of secretory granules.

  • PDF

Radioprotective Effects of Aronia on Radiation Irradiated Rats (방사선에 조사된 쥐에서 아로니아의 방사선 방호효과)

  • Mun, Hwan-Sik;Lee, Jun-Haeng
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.423-431
    • /
    • 2017
  • The present study was intended to orally administer aronia to rats, irradiate radiation once to the whole bodies of the rats, and conduct blood tests to observe, compare, and analyze changes in blood cells, such as leukocytes, erythrocytes, and platelets, in order to examine the radioprotective effects of aronia. As experimental animals, 15 male Sprague-Dawley (SD) rats aged six weeks weighing 200~250 g were taken and divided into the normal group (A) of five rats, the 5 Gy control group (B) of five rats, and the 5 Gy experimental group (C) of five rats. The normal group (A) was not~irradiated at all, the control group (B) was administered with general diets and irradiated, and the experimental group(C) was orally administered with 50 mg/kg/day of aronia two times per day to achieve a distilled water oral dose of 100 mg/kg/day and irradiated thereafter (5 Gy at 500 cGy/min) for 14 days. After the experiment, differences in leukocytes, erythrocytes, and platelets among the normal group (A), the control group (B), and the experimental group (C) were examined by comparing the counts of the blood cells and the results showed no statistically significant differences. However, on a detailed review, the normal group (A) showed statistically higher mean values for all of lymphocytes, hemoglobin, and mean corpuscular hemoglobin as compared to the control group (B) and the experimental group (C). Statistically significant differences in the counts of lymphocytes were shown between the normal group (A) and the control group (B), and between the normal group (A) and the experimental group (C); furthermore, statistically significant differences in mean corpuscular hemoglobin were shown between the normal group (A) and the experimental group (C). Given the results of the present study, in irradiated rats, aronia was generally considered as having no radioprotective effect on leukocyte, erythrocyte, and platelet while having statistically significant radioprotective effects on lymphocytes, hemoglobin, and mean corpuscular hemoglobin. Based on the present experiment, diverse studies should be conducted hereafter.

PET/CT SUV Ratios in an Anthropomorphic Torso Phantom (의인화몸통팬텀에서 PET/CT SUV 비율)

  • Yeon, Joon-Ho;Hong, Gun-Chul;Kang, Byung-Hyun;Sin, Ye-Ji;Oh, Uk-Jin;Yoon, Hye-Ran;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.23-29
    • /
    • 2020
  • The standard uptake values (SUVs) strongly depend on positron emission tomographs (PETs) and image reconstruction methods. Various image reconstruction algorithms in GE Discovery MIDR (DMIDR) and Discovery Ste (DSte) installed at Department of Nuclear Medicine, Seoul Samsung Medical Center were applied to measure the SUVs in an anthropomorphic torso phantom. The measured SUVs in the heart, liver, and background were compared to the actual SUVs. Applied image reconstruction algorithms were VPFX-S (TOF+PSF), QCFX-S-350 (Q.Clear+TOF+PSF), QCFX-S-50, VPHD-S (OSEM+PSF) for DMIDR, and VUE Point (OSEM) and FORE-FBP for DSte. To reduce the radiation exposure to radiation technologists, only the small amount of radiation source 18F-FDG was mixed with the distilled water: 2.28 MBq in the 52.5 ml heart, 20.3 MBq in the 1,290 ml liver and 45.7 MBq for the 9,590 ml in the background region. SUV values in the heart with the algorithms of VPFX-S, QCFX-S-350, QCFX-S-50, VPHD-S, VUE Point, and FOR-FBP were 27.1, 28.0, 27.1, 26.5, 8.0, and 7.4 with the expected SUV of 5.9, and in the background 4.2, 4.1, 4.2, 4.1, 1.1, and 1.2 with the expected SUV of 0.8, respectively. Although the SUVs in each region were different for the six reconstruction algorithms in two PET/CTs, the SUV ratios between heart and background were found to be relatively consistent; 6.5, 6.8, 6.5, 6.5, 7.3, and 6.2 for the six reconstruction algorithms with the expected ratio of 7.8, respectively. Mean SNRs (Signal to Noise Ratios) in the heart were 8.3, 12.8, 8.3, 8.4, 17.2, and 16.6, respectively. In conclusion, the performance of PETs may be checked by using with the SUV ratios between two regions and a relatively small amount of radioactivity.