• Title/Summary/Keyword: distilled water

Search Result 2,421, Processing Time 0.034 seconds

Streptococcus Mutans Biofilm Inhibition Effect of Indocyanine Green and Near Infrared Diode Laser (Indocyanine Green과 근적외선 다이오드 레이저의 Streptococcus mutans 세균막에 대한 억제 효과)

  • Kim, Yeowon;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.4
    • /
    • pp.446-453
    • /
    • 2020
  • The purpose of this study was to evaluate the effect of Indocyanine Green (ICG) and near-infrared (NIR) diode laser on Streptococcus mutans biofilms depending on ICG concentrations. S. mutans biofilms were formed on a Hydroxyapatite disk, and 0.5, 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solutions dissolved in sterile distilled water and a NIR diode laser having a power of 300 mW and a wavelength of 808 nm were applied to the biofilms. The temperature changes of the biofilm surface according to the concentrations of the ICG solution were measured using a 1-channel thermocouple thermometer. Compared to the control group, in the groups with only the 3.0, 4.0, 5.0 mg/mL ICG solution application, and in the groups with the 1.0, 2.0, 3.0, 4.0, 5.0 mg/mL ICG solution application and light irradiation, a statistically significant decrease in the bacterial counts were observed. The temperature increase according to the concentration of the ICG solutions was 9.53℃, 10.43℃, 11.40℃, 12.10℃, 12.67℃, and 13.63℃ in ICG solutions of 0.5, 1.0, 2.0, 3.0, 4.0, and 5.0 mg/mL respectively. This study presents the potential for clinical application of ICG and NIR diode lasers as a new method for preventing dental caries.

Differences of Wood Vinegar Ingestion and Exercise Training on Blood Lipids, MDA, and SOD Activities in Rats (4주간 흰쥐의 목초액 섭취와 운동에 따른 혈중지질과 MDA, SOD 활성 차이)

  • Kang, Jong-Suk;Kim, Sea-Hyun;Kim, Pan-Gi;Lee, Dong-Woon;Ryu, Sung-Pil
    • Journal of Life Science
    • /
    • v.19 no.9
    • /
    • pp.1190-1199
    • /
    • 2009
  • The purpose of this study is to identify the effects of exercise training and oak tree wood vinegar ingestion on the blood lipids and antioxidant activities of rats. The subjects were 28 Sprague Dawley male rats, and they were assigned into four groups (n=7, respectively): the control group (CON), the exercise group (EXE), the vinegar ingestion group (VIN), and the vinegar ingestion and exercise training group (VINEXE). The diet was based on high fat and oral administration of oak tree wood vinegar. The rats that were not given oak tree wood vinegar were given the same amount of distilled water orally in order to maintain the same level of stress. They were exercise trained on motor-driven treadmills during a four-week session. Weight changes in the VINEXE were significantly inhibited in the later period of exercise, when compared to the CON (p<0.05). Fat increase was significantly suppressed in VIN and EXE (p<0.05), and a synergistic effect was discovered in the VINEXE (p<0.05). Glucose and ammonia levels were significantly reduced in the EXE, VIN, and VINEXE compared to the CON (p<0.05). In blood lipids, TC and LDL-C were significantly enhanced in the EXE, VIN, and VINEXE compared to the CON (p<0.05), while HDL-C was significantly improved in the EXE and VINEXE (p<0.05). Liver MDA contents showed significant changes in each group (p<0.05), and SOD activities were significantly enhanced in the VIN and the VINEXE when compared to other groups (p<0.05). Therefore, oak tree wood vinegar ingestion with exercise training for four weeks may result in inhibition of weight gain, improvement of blood lipids, and inhibition of lipid peroxidation, contributing to health promotion.

Study on the Effect of Contact Angles of Elastic Rubber Impression Materials on the Surface of Working Cast (탄성 고무인상재의 접촉각이 작업모형 표면에 미치는 영향)

  • Kim, Joo-Won
    • Journal of dental hygiene science
    • /
    • v.10 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • This study was begun to search effect of contact angles of elastic rubber impression materials on the surface of working cast. Of elastic rubber impression materials with a Type III consistency, such as polysulfide, polyether and addition silicone, we selected one and then measured the contact angle after dripping a distilled water 3.3ml. Then, after pouring a dental anhydrite in three types of impression materials, we prepared a working cast and then examined its surface. Contact angle was measured using a full automatic contact angle measuring system (DM-700, KYOWA, Japan), and the surface of working cast was observed using a field emission scanning electron microscope (JSM-6700F, JEOL Ltd., JAPAN). The following results were obtained: 1) $Mean{\pm}SD$ (SD: standard deviation) of the initial contact angles were $91.3{\pm}20.5^{\circ}$ in the addition silicone materials, $90.0{\pm}2.2^{\circ}$ in the polyethers and $101.5{\pm}2.3^{\circ}$ in the polysulfides. These results indicate that mean values were similar but standard deviations of the three materials showed a great discrepancy. 2) As the time elapsed, addition silicone materials were found to have a contact angle decreased abruptly as compared with the remaining two types. That is, the initial contact angle was $91.3^{\circ}$ and it was abruptly decreased to $29.4^{\circ}$ after 25 seconds. 3) In the polyethers, the initial contact angle was $101.5^{\circ}$ and it was decreased to $90.7^{\circ}$ after 25 seconds. In the polysulfides, however, the initial contact angle was $90.0^{\circ}$ and it was $84.2^{\circ}$ after 25 seconds. This showed almost no changes in the initial contact angles. Moreover, its magnitude was greater than that seen in additional silicones. 4) There were significant differences in the contact angles between the three types of elastic rubber impression materials as the time elapsed (p<0.001). On an observation on the surface of working cast, addition silicone materials were found to have the most dense surface. This was followed by polysulfides and polyethers in a descending order.

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.

Report on the Stability of Freeze-dried Standard Solution (동결건조표준액의 안정성에 관한 보고)

  • Park, Jun Mo;Yoo, Hye Jung;Kim, Han Chul;Han, Geul Soon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.139-148
    • /
    • 2012
  • Purpose : Since standard solution is the one that knows its exact concentration, the curve of the dissolution has been determined according to the amount of the solution, compared to the amount of the unknown sample. Therefore, the antigen that makes up standard materials should be made in a pure form. The configuration of the standard substance solution in the kit we use is a freeze-dried material, or made and comes as a liquid. Lyophilized reference material is used after dissolving in usually D.W. (Distilled Water), and if the antigen to use is too sensitive, reagents should be freeze-dried. Furthermore, when freeze-dried reference has to be frozen again after being dissolved, it should be kept under $-20^{\circ}C$ until the expiration date according to the reports. Since it is not expressed in the experiment if it is safe or stable to reuse the solution which was dissolved a few times, thus, this time it is tested and evaluated that the changes of the standard solution by freezing and melting several times, and its results and the effectiveness of it were compared to the solution which was kept in a fridge. Materials and Methods : Among Vitro diagnostic kits on the market made by radioimmunoassay, parathyroid hormone (PTH), adrenocorticotropic hormone (ACTH), luteinizing hormone (LH) are made of freeze-dried standard solution and all composed of the same Lot.NO. These hormones melted in D.W. and were separated into three groups. In the first group, melting and freezing were repeated, and in the second group, The solution only for one time use was put into a test tube after melting and freeze it. The third group was kept in the refrigerator. This experiment has been conducted from January to February in 2012. January to 2012. PH test was employed because ph is prone to changing depending on the change of protein. Each group of the standard solution, cpm (counter per minute), and the patient relative concentration values were compared by date, and Through the correlation coefficient and Paired t-test, the significant level of each group was analyzed. Results : ACTH, PTH, LH pH values were too subtle denaturation rather than numerical changes in the protein. In addition, when the standard solution of ACTH, PTH, LH was refrigerated, after 3 days and 7 days, there was a significant difference observed between the solution being kept in a refrigerator and a freezer within a significance level. Conclusion : Standard solution should be kept in a freezer, and being kept in a fridge, it is recommended to use the solution as soon as possible.

  • PDF

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

Usability Research of Onco Flash in SPECT (SPECT 검사에서 Onco Flash의 유용성과 질적 향상 평가)

  • Noh, Ik-Sang;Cha, Eun-Sun;Kim, Ki;Choi, Choon-Ki;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.3-8
    • /
    • 2009
  • Purpose: Onco flash shortens a scan time with half and there is a possibility of getting the data which corresponds in existing. The experiment which makes the image whose Onco Flash is excellent OSEM tried, as changes parameter of time, iteration. After reconstituting an image, produces FWHM and executes an evaluation. Materials and Methods: Siemens e.cam gamma camera, standard Jaszczak phantom and spatial resolution phantom was used. In order for the bubble not to enter, implants 2 mCi and volume 0.25 cc $^{99m}Tc$ respectively in line 3 to spatial resolution phantom. Put on that phantom on the table correctly, and acquires an image. 15 mCi putting in distilled water to mix $^{99m}Tc$ well in Jaszczak phantom and acquires image just like spatial resolution phantom. Reconstructs and converts the image to digital image as Sante program. Produce FWHM and evaluate by Amide. Results: The non-scattered image shows better FWHM value than scattered image. As time increases from 10 sec to 30 sec for 5sec interval, FWHM appeared to 30.1, 28.5, 24.5, 23.6, 23.4 mm. At the standard iteration value 4, OSEM FWHM shows 8.0 mm, and Onco Flash is 8.1 mm. As fade in iteration, FWHM value more and more decreased. Conclusion: When using Onco Flash, shortens a scan time, and enhances image quality. Also, user can adjust the parameters to improve resolution. Therefore, patient and user are satisfied with these merits.

  • PDF

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

The Effect of Temperature and Salinity on Maturation and Hatching of Fibricola seoulensis eggs (온도 및 염도가 Fibricola seoulensis 충란의 성숙과 탈각에 미치는 영향)

  • Lee, Soon-Hyung;Lee, Ho-Jin;Hong, Sung-Tae;Huh, Sun;Seo, Byong-Seol
    • Parasites, Hosts and Diseases
    • /
    • v.24 no.2
    • /
    • pp.115-120
    • /
    • 1986
  • This study was carried out to reveal the effect of temperature, salinity and aeration on maturation and hatching of Fibricola seoulensis eggs. The eggs were incubated and were observed daily for the appearance of eyespots and hatching. The results were summarized as follows. 1. From $4{\sim}5$ days after incubation in distilled water at $28^{\circ}C$ or at $11{\sim}26^{\circ}C$, the eyespots began to appear and the rates of eggs with eyespots were over 90% in $28^{\circ}C$ on the 7th or 8th day. However, eyespots did not appear in $5{\sim}15^{\circ}C$ or $4^{\circ}C$ by the 18th day. 2. The mature eggs began to hatch at the 8th day, and hatching rate 2 weeks after incubation was over 90% at $28^{\circ}C$, but it was below 5% at $11{\sim}26^{\circ}C$, and 0% at $5{\sim}15^{\circ}C$ and at $4^{\circ}C$. 3. Aeration did not influence the appearance of eyes pots nor hatching. 4. In salines under 0.6%, the rates of eyespots appearance were over 90% on the 7th day. The rate was 55.0% in 0.9% at 20 days, and 0% in 1.2%. 5. The hatching rates in salines below 0.3% concentration were over 90% by 14 days of incubation. However, the rate decreased to 44% in 0.6% saline and to 0% over 0.9% salinity. 6. The eggs incubated in the dark hatched in 12.5% on the 10th day, but hatching rate of mature eggs increased to 85.7% within 2 hours after exposure to light. Above results demonstrated that the best temperature for maturation and hatching of F. seoulensis eggs was $28^{\circ}C$, and the miracidia began to hatch at $8{\sim}9$ days after incubation. In the field, hatching and invasion into snails of the miracidia may occur from May to September in Korea. In salines under 0.3% concentration maturation and hatching were not influenced, but as salinity increased hatching was inhibited more than maturation was.

  • PDF