• 제목/요약/키워드: distance measuring equipment

검색결과 59건 처리시간 0.023초

Evaluating Accuracy according to the Evaluator and Equipment Using Electronic Apex Locators

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • 제13권2호
    • /
    • pp.52-58
    • /
    • 2020
  • Purpose: Using two types of electronic apex locators, this study aimed to investigate the differences in accuracy according to the evaluator and equipment. Materials and Methods: Artificial teeth of the lower first premolars and two mandibular acrylic models (A and B) were used in this study. In the artificial teeth, the pulp chamber was opened and the access cavity was prepared. Using calibrated digital Vernier calipers, the distance from the top of the cavity and the root apex was measured to assess the actual distance between two artificial teeth. The evaluation was conducted by 20 dentists, and each evaluator repeated measurements for each electronic apex locator five times. The difference between the actual distance from the top of the cavity to the root apex and the distance measured using electronic measuring equipment was compared. For statistical analysis, the Friedman test the Mann-Whitney U-test were conducted and the differences between groups were analyzed (α=0.05). Result: As for the accuracy of measurement according to the two types of electronic apex locators, the value of the measurement error was 0.4753 mm in Dentaport ZX and 0.3321 mm in E-Cube Plus. Moreover, electronic apex locators Dentaport ZX and E-Cube Plus showed statistically significant differences (P<0.05). As for the difference in the accuracy of the two types of electronic apex locators according to the evaluator, the resulting values differed depending on the evaluator and showed a statistically significant difference (P<0.001). Conclusion: Electronic apex locator E-Cube Plus showed higher accuracy than did Dentaport ZX. Nevertheless, both types of electronic apex locators showed 100% accuracy in finding the region within root apex ±0.5 mm zone. Furthermore, according to the evaluator, the two electronic apex locators showed different resulting values.

화학사고 발생에 따른 주민대피 의사결정 지원을 위한 과학조사장비 활용방안 연구 (A Study on the Use of Scientific Investigation Equipment to Support Decision-making of the Resident Evacuation in the Event of a Chemical Accident)

  • 오주연;이태욱;조국
    • 대한원격탐사학회지
    • /
    • 제38권6_3호
    • /
    • pp.1817-1826
    • /
    • 2022
  • 2012년 구미 불화수소 누출사고 이후 정부는 화학사고의 대응과 수습 등 재난관리를 체계화하고 있다. 특히, 행정안전부는 재난 및 안전관리 기본법을 근거로 화학사고 발생에 따른 주민대피에 대한 명령을 소관하고 있으므로 본 연구에서는 국립재난안전연구원의 화학사고 조사장비를 활용한 화학사고 이후 주민대피 의사결정 지원 및 활용방안을 제시하였다. 화학사고로 인한 과학적 정보수집을 위한 장비 운용체계는 상시와 비상시로 구분하여 원거리 측정장비와 근거리 측정장비의 역할 및 활용목적을 중심으로 제시하였다. 원·근거리 측정장비를 통해 취득된 데이터를 활용하여 비상시에는 화학물질의 검출여부를 모니터링하고, 상시에는 업체별 검출물질에 대한 데이터를 관리함으로써 주민대피 의사결정을 위한 기초자료로 활용할 수 있다. 상시 운용체계에 한하여 장비별로 현장 활용성을 검증하기 위해 화학물질을 측정한 결과, 원거리 측정장비에서는 화학물질의 실시간 검출이 가능함을 확인하였으며, 추후 장비의 측정가능 거리 및 범위에 대한 확인이 필요하다는 점을 확인할 수 있었다. 근거리 측정장비의 경우, 탄화수소 계열의 물질이 주로 검출되며, 온산국가산업단지에 비해 울산·미포국가산업단지에서 높은 수준으로 측정된 것을 확인하였다. 향후 지속적인 데이터 구축을 통해 화학사고 발생에 따른 의사결정 지원을 위한 기초자료로 활용될 수 있을 것으로 기대된다.

적외선열화상처리장치를 이용한 충돌제트의 전열특성에 관한 연구 (A Study on Heat Transfer Characteristics of Impinging Jet Using Infared Thermal Image Processing System)

  • 김동균;배석태;김시범;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.711-716
    • /
    • 2001
  • This paper presents an information about the heat transfer characteristics of impinging jet in eletronic equipment with infrared image processing unit. There have been many experimental investigations and theoretical studies on impinging jet because of application in a wide variety of industrial process including electronic equipment. In this study, we used infrared image processing unit to visualize heat transfer characteristics of impinging jet in electronic equipment. Infrared image processing unit is one of non-contact temperature measuring methods and it is possible to minimize flow resistance and this measurement is comparatively accurate. The main parameters are nozzle exit angle $(30^{\circ},\;45^{\circ},\;60^{\circ},\;75^{\circ},\;90^{\circ})$ and distance between nozzle and heat source is fixed 6d("d" is diameter of circular nozzle(10 mm). Reynolds number is 4500.

  • PDF

국소영역에서 이동표적의 상대위치 측정 장치 개발 (Development of Relative Position Measuring Device for Moving Target in Local Area)

  • 서명국
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.8-14
    • /
    • 2020
  • Intelligent devices using ICT technology have been introduced in the field of construction machinery to improve productivity and stability. Among the intelligent devices, Machine Guidance is a device that provides real-time posture, location, and work range to drivers by installing various sensors, controllers, and satellite navigation systems on construction machines. Conversely, the efficiency of equipment that requires location information, such as machine guidance, will be greatly reduced in buildings, and tunnels in the GPS blind spots. Thus, the other high-precision positioning technologies are required in the GPS blind spot zone. In this study, we will develop a relative position measurement system that provides precise location information such as construction machinery and robots in a local area where the GPS reception is difficult. A relative position measurement system tracks a marker in the form of a sphere installed on a vehicle by using the image base tracking technology, and measures the distance and direction information to the marker to calculate a position.

고속철도 전기제동 특성에 관한 연구 (A Study on Electric Braking Characteristic of High-Speed Train)

  • 김석원;한영재;박찬경;김영국;김종영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.269-271
    • /
    • 2004
  • In this study, on-line measuring system were developed to verify performances and characteristics of electric braking system that is used in KTX(Korea Train eXpress) synthetically and efficiently Because KTX is commercial vehicle, effective measurement and evaluation of measuring signals were performed beyond the range of change for equipment components. KRRI(Korea Railroad Research Institute) described about running-braking measuring program, running-braking backup program and running-braking analysis program that were developed using a software called LabVIEW in this paper. Also, we analyzed the characteristics comparing experimental values with design values about braking distance, braking time, negative acceleration and braking effort in rheostatic braking and regenerative braking. In result, main performances and characteristics for electric braking system in KTX were verified.

  • PDF

혈관조영장비의 테이블-피사체간 거리 변화에 따른 혈관측정 정확도 연구 (Study on the Accuracy of Vessel Measurement According to Table Object Distance Changes)

  • 김승기
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.435-440
    • /
    • 2019
  • This is to study the accuracy of the actual size according to the TOD(table object distance; TOD) change when measuring blood vessels using angiography equipment, and to help the optimal selection of the device used accordingly. Balls similar to the size of common vessels were calibrated with TOD using 30 mm, 20 mm, 10 mm, 5 mm and acrylic phantoms, catheter calibration from 0 cm to 10 cm, 20 cm and 30 cm, respectively. It was measured whether there was a change in the measured value according to the change. The equipment used was GE Innova 3131 IQ equipment, and the image reconstruction method was GE AW4.7 post processing program. Two radiotechnologists were scanned three times by catheter calibration method and 3DRA(3dimension rotational angiography; 3DRA) volume rendering method. The independent sample T-test showed 0.981 (p> 0.05) to verify the significance between the two observers. As a result, in case of catheter calibration, the error rate at TOD 0 mm and 10 mm is within ± 10%, but when the TOD is changed to 20 mm and 50 mm respectively, the tolerance is ± 10% except for 30 mm ball exceeded. On the other hand, 3DRA was included within the tolerance range of ± 10% overall even when the TOD was changed from 0 mm to 50 mm. In the catheter calibration method, the larger the TOD, the larger the error range, and the 3DRA method was able to measure vascular vessels accurately close to the actual measurement without any consideration of the TOD.

신속한 적조 예찰이 가능한 형광 측정시스템 개발 (Development of a Fluorescence Measurement System Capable of Rapid Red Tide Monitoring)

  • 백경훈;오영지;조현서;강윤자;이준석
    • 센서학회지
    • /
    • 제33권1호
    • /
    • pp.30-33
    • /
    • 2024
  • The occurrence of harmful algae on the coast of Korea has been a cause of damage to the aquaculture industry and deterioration of the coastal ecosystem environment. A method is required to predict their outbreak in real-time at the site. Therefore, this study attempted to develop a small hybrid optical sensor and real-time monitoring system based on LiDAR that can be used in the field and laboratory and can be applied to various platforms. FMS-L specifically suggested the amount of Chlorophyll a (Chl a) in the sample by measuring and analyzing the fluorescence emitted by the irradiating light. The accuracy of FMS-L was verified by measuring the concentrations of standard Chlorophyll a substances and Margalfidinium polykirkoids. In addition, the precision was verified by comparing the measurement results of FMS-L using commercial equipment Phyto-PAM-II. This equipment is compact and easy to move. Therefore, it can be easily applied to field surveys, allows short time measurements (10 s), and can be applied at a distance of 10 m from the measurement site.

LabView를 이용한 자동차 제동시험 S/W 구현 (Implementation of Software for the Brake Test in the Vehicle using the LabView)

  • 강준환;김선형
    • 한국정보통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.752-757
    • /
    • 2008
  • 본 논문은 자동차의 정차 또는 주행 중 다양한 조건으로 제동 거리와 제동 안정성 시험을 할 수 있는 제동시험용 계측 S/W를 개발하였다. 본 논문에서 구현한 자동차 제동시험 용 계측 S/W는 제동시험에 대한 객관성을 확보하고, 제동시험에 대한 반복 재현성을 확보하여 현재 세계 각 국에서 실시하고 있는 다양한 제동 거리와 제동 안정성 시험에 적용할 수 있다. 자동차 제동시험용 계측기를 자동차에 장착하여, 정차 상태와 주행 중에 신차평가제도(NCAP)의 시험 조건과 자동차 제작사인 A, B사의 자체 시험조건에 맞추어 제동 거리와 제동 안정성 시험을 하였고, 모든 시험 조건에 맞는 시험을 할 수 있었으며, 보다 가혹한 시험 조건에도 적용해 봄으로써 차후 시험 조건이 변경 될 경우에도 본 논문에서 제작한 계측 S/W의 적용 가능성을 확인하였다.

적외선 열화상 카메라를 이용한 용접부의 온도 측정 방법 (Method for Measuring Weld Temperature Using an Infrared Thermal Imaging Camera)

  • 노찬승;김경석;장호섭
    • 비파괴검사학회지
    • /
    • 제34권4호
    • /
    • pp.299-304
    • /
    • 2014
  • 본 연구에서는 적외선 열화상 카메라와 열원 사이에 유리를 설치하여 측정기기의 보호 및 온도 보정을 통하여 고온의 용접부 온도를 실시간으로 측정하고자 하였다. 먼저 할로겐램프의 열에 대한 온도 차이를 실시간으로 촬영하고 온도를 측정한 결과, 카메라와 열원 사이의 거리별 온도는 거의 동일하게 측정되었음을 확인할 수 있었고, 유리 두께와 측정 거리의 상관관계를 통하여 온도 범위를 예측할 수 있다는 것을 알 수 있었다. 이를 바탕으로 용접열원에 대한 실험을 수행하여 열화상 카메라를 이용한 용접부의 온도 측정의 타당성을 제시하였다.

음향 이방성을 고려한 티타늄 용접부의 결함길이 측정에 관한 연구 (A Study on the Defect length Measurement of Titanium Weld Zone Considering Acoustical Anisotropy)

  • 박희동;윤인식;이원
    • 한국정밀공학회지
    • /
    • 제28권9호
    • /
    • pp.1070-1077
    • /
    • 2011
  • This study intends to assess the defect in the weld zone of titanium grade 2 plate in terms of acoustical anisotropy based on the angle beam method. Depending on the rolling direction, the ratio of wave velocity was found to be 1.08 and the difference in the angle of refraction was more than seven degrees, confirming the presence of acoustical anisotropy. Thus for measuring the length of defect in the weld zone of the titanium plate (thickness of 10mm), the distance amplitude characteristics curves of titanium, TDACC-R and TDACC-T were constructed for the measurements in consideration of the acoustical anisotropy on CRT of the ultrasonic testing equipment. As a result, when the distance amplitude characteristics curve corresponds to the rolling direction, the length of defect was close to the actual measurement within 1mm and when different, the difference was found to be over 4mm. It was affirmed that the acoustical anisotropy should be taken into consideration when measuring the length of defects in the weld zone of the titanium plate with the presence of acoustical anisotropy.