• 제목/요약/키워드: distance measurement error

Search Result 395, Processing Time 0.022 seconds

Developement of Safety Management System of Multi-Laborers Using RTLS in the Pavement and Bridge Construction Field (도로포장 및 교량 유지보수 현장에서 RTLS를 활용한 다중 노무자의 안전관리 시스템 개발)

  • Song, Ki-Il;Lim, Jin-Sun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Real time location system was development for safety management at road and bridge maintenance field. The system can check the real-time location detection, movement history, behavior of a number of laborers. The system consisted of a Bluetooth and ZigBee that uses low-power. It had a very large error that the previous method for the position recognition by triangulation using the RSSI. Because This study proposed a new distance measurement and correction scheme using RSSI and accelerometer. It was evaluated in the maintenance field. A development system were evaluated in the field, the results are shown an error between 0.2 m and 0.4 m. And through the acceleration of history it was confirmed by determining possible to determine the safety situation of the laborers.

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향)

  • 이복희;어주홍;김성원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-104
    • /
    • 2001
  • The effects of the position of potential probe on the measurements of the ground resistance in the fa11-of-potential method are described. The ground resistance is theoretically calculated by applying the 61.8[%] rule, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring potential and current probes in on-site test might not be arranged on the straight line with adequate distance because there are building, roadblock construction and other establishments. Provided that the grounding electrode to be measured and the measuring potential probes are out of position on the straight line, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. In this work, measurements were focused on the grounding electrode system made by the ground rods of 2.4 m long. The measuring error was increased with increasing the angle which is made by the 3-points of the grounding electrode to be measured, the potential anti current probes, and it was a negative. That is, all of the measured ground resistances ware less than the true ground resistance.

  • PDF

Sensing Technologies for Grain Crop Yield Monitoring Systems: A Review

  • Chung, Sun-Ok;Choi, Moon-Chan;Lee, Kyu-Ho;Kim, Yong-Joo;Hong, Soon-Jung;Li, Minzan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.408-417
    • /
    • 2016
  • Purpose: Yield monitoring systems are an essential component of precision agriculture. They indicate the spatial variability of crop yield in fields, and have become an important factor in modern harvesters. The objective of this paper was to review research trends related to yield monitoring sensors for grain crops. Methods: The literature was reviewed for research on the major sensing components of grain yield monitoring systems. These major components included grain flow sensors, moisture content sensors, and cutting width sensors. Sensors were classified by sensing principle and type, and their performance was also reviewed. Results: The main targeted harvesting grain crops were rice, wheat, corn, barley, and grain sorghum. Grain flow sensors were classified into mass flow and volume flow methods. Mass flow sensors were mounted primarily at the clean grain elevator head or under the grain tank, and volume flow sensors were mounted at the head or in the middle of the elevator. Mass flow methods used weighing, force impact, and radiometric approaches, some of which resulted in measurement error levels lower than 5% ($R^2=0.99$). Volume flow methods included paddle wheel type and optical type, and in the best cases produced error levels lower than 3%. Grain moisture content sensing was in many cases achieved using capacitive modules. In some cases, errors were lower than 1%. Cutting width was measured by ultrasonic distance sensors mounted at both sides of the header dividers, and the errors were in some cases lower than 5%. Conclusions: The design and fabrication of an integrated yield monitoring system for a target crop would be affected by the selection of a sensing approach, as well as the layout and mounting of the sensors. For accurate estimation of yield, signal processing and correction measures should be also implemented.

A Study on the Performance of Multicast Transmission Protocol using FEC Method and Local Recovery Method based on Receiver in Mobile Host (이동 호스트에서 FEC기법과 수신자 기반 지역복극 방식의 멀티캐스트 전송 프로토콜 연구)

  • 김회옥;위승정;이웅기
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.1
    • /
    • pp.68-76
    • /
    • 2002
  • Multicast in mobile host has the problem of hast mobility, multicast decision, triangle routing, tunnel convergence, implosion of retransmission, and bandwidth waste. In particular, the bandwidth waste in radio is a definite factor that decreases transmission rate. To solve the problems, this paper proposes a new multicast transmission protocol called FIM(Forward Error Correction Integrated Multicast), which supports reliable packet recovery mechanism by integrating If Mobility Support for the host mobility, IGMP(Interned Group Management Protocol) for the group management, and DVMRP(Distance Vector Multicast Routing Protocol) for the multicast routing, and it also uses FEC and the local recovery method based on receiver. The performance measurement is performed by dividing the losses into the homogeneous independent loss, the heterogeneous independent loss, and the shared source link loss model.. The result shows that the performances improves in proportion to the size of local areal group when the size of transmission group exceeds designated size. This indicates FIM is effective in the environment where there are much of data and many receivers in the mobile host.

  • PDF

Measurement of LPWA communication coverage in NLOS environment (NLOS 환경에서 LPWA 통신 커버리지 측정)

  • Kwon, Hyuk;Jin, Kyoung-Bog;Oh, Chang-Heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.591-593
    • /
    • 2019
  • LPWA has a small amount of data that can be transmitted at one time, but it can collect a very wide range of information, so it is suitable for gathering information of apartment meter or collecting data intermittently sent from industrial site. However, most of the application studies on LPWA are limited to outdoor, especially LOS environment, so it is difficult to collect information for application to apartment and industrial sites. In this paper, we have measured the communication coverage within the building, which is a NLOS environment, so that LPWA communication can be applied to apartments and industrial sites. For the experiment, LoRa module was created using sx1276, Class A was applied, and the spread factor was changed for each layer. As a result, in case of spreading factor 7 that shows increasing error and losses from the 7 floor, but the in case of spreading factor 12, the data could be seamlessly received even on the 9th floor without error and losses.

  • PDF

A Study on Indoor Position-Tracking System Using RSSI Characteristics of Beacon (비콘의 RSSI 특성을 이용한 실내 위치 추적 시스템에 관한 연구)

  • Kim, Ji-seong;Kim, Yong-kab;Hoang, Geun-chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.85-90
    • /
    • 2017
  • Indoor location-based services have been developed based on the Internet of Things technologies which measure and analyze users who are moving in their daily lives. These various indoor positioning technologies require separate hardware and have several disadvantages, such as a communication protocol which becomes complicated. Based on the fact that a reduction in signal strength occurs according to the distance due to the physical characteristics of the transmitted signal, RSSI technology that uses the received signal strength of the wireless signal used in this paper measures the strength of the transmitted signal and the intensity of the attenuated received signal and then calculates the distance between a transmitter and a receiver, which requires no separate costs and makes to implement simple measurements. It was applied calculating the value for the average RSSI and the RSSI filtering feedback. Filtering is used to reduce the error of the RSSI values that are measured at long distance.It was confirmed that the RSSI values through the average filtering and the RSSI values measured by setting the coefficient value of the feedback filtering to 0.5 were ranged from -61 dBm to - 52.5 dBm, which shows irregular and high values decrease slightly as much as about -2 dBm to -6 dBm as compared to general measurements.

The Thickness Measurement of Masticatory Mucosa on the Hard Palate and Maxillary Tuberosity in Healthy Korean Adults (건강한 한국 성인에서 경구개와 상악결절 부위 저작점막의 두께 측정)

  • Cho, Ik-Hyun;Park, Jung-Mi;Chang, Moon-Taek;Kim, Hyung-Seop;Kim, Hyun-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.641-649
    • /
    • 2001
  • The aim of present study was to assess the thickness of masticatory mucosa on the hard palate and tuberosity as a potential donor site for mucogingival surgery. Thickness measurement was performed in 30 dental college students who are periodontally healthy, with a recently developed, ultrasonic device(SDM). The mean age of study subjects was 23.7(range 21-29) years old and the subjects were composed of 18 males and 12 females. Eighteen standard measurement points were defined on the hard palate, located on 3 lines which ran at different distances parallel to the gingival margin. Six positions were designated on each of these 3 lines between the level of the canine and the second molar. On the tuberosity, 6 standard measurement points were defined, located on 2 lines running parallel to the gingival margin at different distances. Data were analyzed to determine differences in gender, between different positions, and between lines, by an analysis of variance. The results showed that the mucosa of the tuberosity was significantly thicker than that of the hard palate region. Gender did not influence the thickness of masticatory mucosa, either on the hard palate or the tuberosity. On the hard palate, mucosa thickness increased as the distance from the marginal gingiva increased. The mucosa over the palatal root of the maxillary first molar was significantly thinner than that at all other positions on the hard palate. Measurement error at palate was 0.25mm, at tuberosity 0.51mm. No difference in the thickness of masticatory mucosa on palate and tuberosity was found between men and women. On the hard palate, soft tissue thickness progressively increased in sites further from the gingival margin. Therefore, we may harvest more thicker graft on the tuberosity that has more masticatory mucosa thickness than hard palate, however the width may not be sufficient for using.

  • PDF

Evaluation of the Accuracy of Grounding Impedance Measurement of Grounding Grid (접지그리드의 접지임피던스 측정의 정확도 평가)

  • Choi, Jong-Hyuk;Choi, Young-Chul;Jeong, Dong-Cheol;Kim, Dong-Seong;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.146-153
    • /
    • 2009
  • Recently, the common grounding systems are adapted in most large structures. Since the ground resistance is insufficient to evaluate the performance of grounding systems, it is needed to measure grounding impedance. Even though the methods of measuring grounding impedance of large grounding systems are presented in IEEE standard 81.2, but they have not been described in detail. In this paper, we present the accurate method of measuring grounding impedance based on the revised fall-of-potential method and measurement errors due to earth mutual resistance and ac mutual coupling depending on locating test electrodes at remote earth were examined for the 15[m]$\times$15[m] grounding grid. As a result, the measurement error due to earth mutual resistance is decreased when the distance to auxiliary electrodes increased. To get rid of measurement errors due to mutual coupling, the potential lead should be installed at a right angle to the current lead. When the angle between the potential and the current leads is an acute angle or an obtuse angle, the mutual couple voltage is positive or negative, respectively. Generally, the measurement errors due to mutual coupling with an obtuse angle route are lower than those with an acute angle route.

Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향)

  • 이복희;엄주홍
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.69-77
    • /
    • 2000
  • In this paper, the effects of the positions of the potential and current probes on the measurements of the ground resistance and potential gradients with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and ground resistance of the measuring probes. The ground resistance is calculated by applying the 61.8% and rule in the fall-of-potential method, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring probes in on-site test might not be arranged on the straight line with adequate distance because there are building, road block, construction and other establishments. Provided that the grounding electrode to be measured and the measuring probes ar out of position on the straight line or have inadequate distance, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. Measurements were focused on the grounding electrode system made by the ground rods of 2.4m long. It was found that the suitable separation between the grounding electrode to be measured and the current probe is more than 5 times of the length of the grounding electrode to be measured.

  • PDF