• Title/Summary/Keyword: dissipation test

Search Result 752, Processing Time 0.027 seconds

A study on insulation characteristics with AC Breakdown Test for Stator Winding of 3.3kV class Induction Motor (절연파괴시험을 통한 3.3kV 유도전동기의 절연특성 연구)

  • Lee, Dong-Geun;Lee, Kwang-Ho;Choi, Kyo-Nam;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2118-2122
    • /
    • 2005
  • This test was performed to assess the corelation of insulation deterioration condition with breakdown voltage of the stator winding of 3.3kV class induction motors which have been in service for 10 years after being installed in 1993. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor$({\Delta}tan{\delta})$, maximum partial discharges (Qmax) and AC breakdown test. we evaluated the corelation of insulation diagnostic test with AC breakdown test for stator wilding of high voltage induction motor.

  • PDF

Change of the Insulation Characteristic for the Rotating machine stator winding after insulation reinforcement (회전자 고정자권선의 절연보수후 절연특성변화 연구)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.51-52
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

Seismic Performance Test of Concrete Column Reinforced with EPFT (EPFT 강관기둥으로 보강된 콘크리트 기둥의 내진성능실험)

  • Kim, Yu-Seong;Lee, Joon-Ho;Kim, Gee-Chul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.3
    • /
    • pp.73-80
    • /
    • 2022
  • Unlike the CFT retrofit method, The EPFT retrofit method, which fills the steel tube with engineering plastic, does not require a separate concrete forming work and is a lightweight seismic Retrofit Method. In this study, an prototype model of the EPFT was proposed, and to analyze the seismic performance, an independent specimens and a reinforced concrete column were fabricated to conduct a seismic performance test. As a result of loading test of the independent specimens, the strength was increased compared to the steel tube column without internal filling, and the ductility ratio did not significantly increase due to the falling off of the weld. As a result of loading test of the concrete reinforcement specimen, the strength, ductility ratio, and energy dissipation were increased, and the number of cracks by loading step decreased compared to the non-reinforced specimen.

Test Scheduling of NoC-Based SoCs Using Multiple Test Clocks

  • Ahn, Jin-Ho;Kang, Sung-Ho
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.475-485
    • /
    • 2006
  • Network-on-chip (NoC) is an emerging design paradigm intended to cope with future systems-on-chips (SoCs) containing numerous built-in cores. Since NoCs have some outstanding features regarding design complexity, timing, scalability, power dissipation and so on, widespread interest in this novel paradigm is likely to grow. The test strategy is a significant factor in the practicality and feasibility of NoC-based SoCs. Among the existing test issues for NoC-based SoCs, test access mechanism architecture and test scheduling particularly dominate the overall test performance. In this paper, we propose an efficient NoC-based SoC test scheduling algorithm based on a rectangle packing approach used for current SoC tests. In order to adopt the rectangle packing solution, we designed specific methods and configurations for testing NoC-based SoCs, such as test packet routing, test pattern generation, and absorption. Furthermore, we extended and improved the proposed algorithm using multiple test clocks. Experimental results using some ITC'02 benchmark circuits show that the proposed algorithm can reduce the overall test time by up to 55%, and 20% on average compared with previous works. In addition, the computation time of the algorithm is less than one second in most cases. Consequently, we expect the proposed scheduling algorithm to be a promising and competitive method for testing NoC-based SoCs.

  • PDF

Permeability Characteristics of Soft Clay using the Piezocone Test and a Laboratory Test (피에조 콘 시험과 실내시험을 이용한 점토지반의 투수특성 연구)

  • Gu, Nam-Sil;Kim, Young-Min;Park, Jae-Hwhan;Jang, Ji-Guen
    • The Journal of Engineering Geology
    • /
    • v.21 no.4
    • /
    • pp.349-359
    • /
    • 2011
  • The consolidation behavior of soft clay is controlled mainly by its compressibility and deformation characteristics. Soil permeability depends on various soil characteristics, including the soil type and anisotropy. The coefficient of permeability of soft clay is determined by using a laboratory test (the Oedometer test) or a piezocone test. The latter test is useful for estimating the permeability characteristics from $c_h$ and $k_h$ by performing an excess pore-pressure dissipation test. This study seeks to validate an existing theoretical formula in applying it to marine clay, and to assess the relation between $k_h/k_c$ and the mechanical properties of soft clay. Piezocone tests and laboratory tests were performed using sediment from the Yellow Sea and from the South Sea near Korea. We compared $k_h/k_v$ values obtained using the piezocone test and using laboratory consolidation tests. The obtained values are similar to the values obtained by Jamiolkowski et al. (M application); therefore, the latter values are recommended to be used as $k_h/k_v$.

Seismic Performance Evaluation of Existing RC Bridge Piers by Pseudo Dynamic Test (유사동적 실험에 의한 기존 RC 교각의 내진성능 평가)

  • 박종협
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.364-371
    • /
    • 2000
  • The pseudo dynamic test has been carried out so as to investigate the seismic performance of RC bridge piers strengthened with and without glass fiber sheets. The Lessons from severe demage of many infrastructures in Kobe(1995) and Northridge(1996) earthquakes have emphasized the need to develop the retrofit measures to enhance flexural strength, ductility and shear strength of RC bridge piers nonseismically designed before 1992. Therefore, the objective of this experimental research is to investigate the seismic behavior of circular reinforced concrete bridge piers by the pseudo dynamic test. and then to enhance the ductility of concrete piers strengthening with glass fiber sheets in the plastic hinge region. 7 circular RC bridge piers were made in a 1/3.4 scale. Important test parameters are confinement steel ratio, retrofitting. load pattern, etc. The seismic behavior of circular concrete piers under artificial ground motions has been evaluated through strength and stiffness degradation, energy dissipation. It can be concluded that existing bridge piers wrapped with glass fibers in the plastic hinge regions could have enough seismic performance.

  • PDF

Evaluation on Seismic Performance of Limited Ductile RC Bridge Piers by Pseudo-Dynamic Test

  • Chung, Young-Soo;Park, Jong-Heob;Cho, Chang-Beck;Seo, Joo-Won
    • KCI Concrete Journal
    • /
    • v.13 no.2
    • /
    • pp.3-9
    • /
    • 2001
  • Pseudo dynamic test for seven circular RC bridge piers has been carried out to investigate their seismic performance subjected to expected artificial earthquake motions. The objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete bridge piers, which have been widely used for railway and urban transportation facilities. Important test parameters are confinement steel ratio, and input ground motion. The seismic behavior of circular RC bridge piers under artificial ground motions has been evaluated through displacement ductility, cumulative energy input, and dissipation capacity. It can be concluded that RC bridge piers designed in a limited ductile behavior provision of Eurocode 8 have been determined to show good seismic performance even under moderate artificial earthquakes.

  • PDF

Analysis on Component and Mechanical Characteristics for Crushed Stone of Excavated Rocks(II) (지하굴착암 쇄석의 성분 및 역학적 특성 분석(II))

  • 이상호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.1
    • /
    • pp.83-90
    • /
    • 2003
  • In order to offer some fundamental data for recycling the excavated rocks, the component and mechanical characteristics was investigated for the excavated rocks, by means of X-ray diffraction analysis, strength test, slacking test and abrasion test were performed. It appeared that the unconfined compressive strength and the elastic wave velocity were the highest in the sound rock. The dissipation rate by stability tests was found to be high in the case of the slacking index of 98% because of more bedding and more clay minerals. The apparent specific gravity of some crushed aggregate was decreased because they included easily weathered minerals while both the absorption and the abrasion were increased. The results in this study were expected to be useful for recycling the excavated rocks as a concrete aggregate.

Quasi-static test of the precast-concrete pile foundation for railway bridge construction

  • Zhang, Xiyin;Chen, Xingchong;Wang, Yi;Ding, Mingbo;Lu, Jinhua;Ma, Huajun
    • Advances in concrete construction
    • /
    • v.10 no.1
    • /
    • pp.49-59
    • /
    • 2020
  • Precast concrete elements in accelerated bridge construction (ABC) extends from superstructure to substructure, precast pile foundation has proven a benefit for regions with fragile ecological environment and adverse geological condition. There is still a lack of knowledge of the seismic behavior and performance of the precast pile foundation. In this study, a 1/8 scaled model of precast pile foundation with elevated cap is fabricated for quasi-static test. The failure mechanism and responses of the precast pile-soil interaction system are analyzed. It is shown that damage occurs primarily in precast pile-soil interaction system and the bridge pier keeps elastic state because of its relatively large cross-section designed for railways. The vulnerable part of the precast pile with elevated cap is located at the embedded section, but no plastic hinge forms along the pile depth under cyclic loading. Hysteretic curves show no significant strength degradation but obvious stiffness degradation throughout the loading process. The energy dissipation capacity of the precast pile-soil interaction system is discussed by using index of the equivalent viscous damping ratio. It can be found that the energy dissipation capacity decreases with the increase of loading displacement due to the unyielding pile reinforcements and potential pile uplift. It is expected to promote the use of precast pile foundation in accelerated bridge construction (ABC) of railways designed in seismic regions.

Earthquake Resistance of Beam-Column Connection of Precast Concrete U-Shaped Shell Construction (프리캐스트 콘크리트 U형 쉘 공법 보-기둥 접합부의 내진성능)

  • Im, Hyeong-Ju;Park, Hong-Gun;Eom, Tae-Sung;Kang, Su-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.741-751
    • /
    • 2010
  • An experimental study was performed to investigate the earthquake resistance of the beam-column connections as a part of a precast concrete moment-resisting frame that uses precast concrete U-shaped shells for the beams. Five full-scale precast concrete specimens and one conventional monolithic concrete specimen were tested under cyclic loading. The parameters for this test were the reinforcement ratio, stirrup spacing, and end-strengthening details of the precast beam shell. The test results showed that regardless of the test parameters, the precast concrete beam-column connections showed good load-carrying capacity and deformation capacity, which were comparable to those of conventional monolithic concrete specimen. However, at large deformations, the beam-column connections of the precast concrete specimens were subjected to severe strength degradation due to diagonal shear cracks and the bond-slip of re-bars at the joint region. For this reason, the energy dissipation capacity and stiffness of the precast concrete specimens were significantly less than those of the cast-in-place specimen.