• Title/Summary/Keyword: dissipation factor

검색결과 394건 처리시간 0.035초

La 첨가량에 따른 Bi$_{4-x}La_x$Ti$_3O_12$ 강유전체의 주파수특성 (The Ferroelectric Frequency characteristics of Bi$_{4-x}La_x$Ti$_3O_12$ ceramics with the variation of Lanthanum additives)

  • 김응권;박복기;박기엽;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.463-466
    • /
    • 2001
  • In recent year, Ferroelectric BLT($Bi_{4-x}$La$_{x}$Ti$_3$O$_{12}$) is a promising candidate materials. This study was Practiced to make good conditions of BLT targets. In this study, calcination and sintering temperature were kept at 75$0^{\circ}C$, 110$0^{\circ}C$ for 2 hour respectively. the density obtained 7.612, 7.98, 7.877 g/㎤ as La$_2$O$_3$ contents were 0.0mol%, 0.25mo1%, 0.5mol%. Especially, the lanthanum content of 0.5 mol% measured C-axis (117) preferred orientation more than the others targets in the XRD. In $\varepsilon$$_{r}$-f relationship using by HP 4194 A impedance analyzer, the 0.5 mol% observed above 200 relative dielectric constant. but the dissipation factor was higher than others targets at 100Hz~13MHz range. SEM photograph with the content of La$_2$O$_3$ was observed like rod and plate types.types.s.

  • PDF

RF 마그네트론 스퍼터링법으로 성장시킨 0.5% Ce-doped Ba(Zr0.2Ti0.8)O3 (BCZT) 박막의 열처리 특성분석 (Characterization of the Annealing Effect of 0.5 % Ce-doped Ba(Zr0.2Ti0.8)O3 Thin Films Grown by Rf Magnetron Sputtering Method)

  • 최원석;박용섭;이준신;홍병유
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.361-364
    • /
    • 2003
  • It was investigated that the structural and electrical Properties of Ce-doped Ba(Zr$_{x}$Ti$_{1-x}$ )O$_3$ (BCZT) thin films with a mole fraction of x=0.2 and a thickness about 100 nm. BCZT films were prepared on Pt/Ti/SiO$_2$/Si substrate by a RF magnetron sputtering system. We have measured the thickness profile with Ar/O$_2$ ratio and the surface roughness. It was observed that the oxygen gas, which introduced during the film deposition, have an influence on the roughness of the film and the film roughness was reduced by annealing from 2.33 nm to 2.02 nm (RMS at 500 $^{\circ}C$, Ar:6 sccm, $O_2$:6 sccm). It was found that annealing procedure after top electrode deposit can reduce the dissipation factor.

Suitability of Palm Based Oil as Dielectric Insulating Fluid in Transformers

  • Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Mohtar, Mohd Nazim
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.662-669
    • /
    • 2014
  • Mineral oil has been widely used as dielectric insulating fluid in transformers due to its excellent performance in-service. However, there are few issues with mineral oil such as it has poor biodegradability and could contaminate the environment if a spillage occurs. With the increasing tight regulation on safety and environment, alternative fluids for mineral oil are currently being investigated and among the suitable candidate is the vegetable oil. There are different types of vegetable oils and one of them is the palm based oil. At the moment, extensive research works are carried out to examine its feasibility to be applied in transformers. This paper will review the previous research works that were carried out to examine the suitability of palm based oil as dielectric insulating fluid in transformers. The physical and chemical properties of palm based oil are studied based on viscosity, acidity, oxidation stability and flash point. Next, the electrical characteristics of palm based oil are examined based on AC breakdown voltage, relative permittivity, dissipation factor and partial discharge.

Zn-Pr-Co-Cr-Er 산화물계 바리스터의 써지 스트레스에 대한 전기적 안정성에 미치는 소결온도의 영향 (Effect of Sintering Temperature on Electrical Stability against Surge Stress of Zn-Pr-Co-Cr-Er Oxides-based Varistors)

  • 남춘우;박종아;유대훈
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1167-1173
    • /
    • 2004
  • This paper reports the variations of varistor voltage, nonlinear exponent, leakage current, and dissipation factor against surge stress of ZnO-P $r_{6}$ $O_{11}$-CoO-C $r_2$ $O_3$-E $r_2$ $O_3$(ZPCCE)-based varistors manufactured with the variations of sintering temperature. It was found that the variations of electrical parameters against surge stressing current of 100 A/$\textrm{cm}^2$(8x20 ${\mu}\textrm{s}$) is not so large under the surge stress of 700 times. Among varistors, specially the varistor sintered at 134$0^{\circ}C$ exhibited the smallest variations, with %$\Delta$ $V_{lmA}$=+0.23%, %$\Delta$$\alpha$=+0.23%, %$\Delta$ $I_{L}$=0%, %$\Delta$tan$\delta$=-6.94%. The clamping voltage ratio( $V_{c}$/ $V_{lmA}$) of all varistors was less than 2.2.2.2.2.2.2.

고압전동기 고정자 권선의 절연열화 분석 (Analysis of Insulation Aging in High Voltage Motor Stator Windings)

  • 김희동;공태식;이영준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.200-203
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in eight high voltage motors. Diagnostic tests included polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 motor failed near rated voltage of 12.96 kV. The breakdown voltage of No. 4 motor was 6.99 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

  • PDF

Effect of Nano/micro Silica on Electrical Property of Unsaturated Polyester Resin Composites

  • Sharma, Ram Avatar;D'Melo, Dawid;Bhattacharya, Subhendu;Chaudhari, Lokesh;Swain, Sarojini
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권1호
    • /
    • pp.31-34
    • /
    • 2012
  • The addition of nano/micro silica into unsaturated polyester resin (UPR) results in the improvement of the electrical properties of Silica-UPR composites. The surface, volume resistivity, dielectric strength, dissipation factor and dry arc resistivity of nano silica-UPR composites were found to improve significantly. The effects of the nano and micro fillers in UPR have been evaluated. They are presented in this paper. To evaluate the electrical properties of the nano & micro composites, all the measurements were done as per the prescribed methods in ASTM. It was observed that the addition of nano silica improves the electrical properties as compared to micro silica. The better dispersion of silica particles in unsaturated polyester resin enhances the electrical properties of silica-UPR composites.

AlN 기판을 이용한 RF 고전력 증폭기 모듈 (RF High Power Amplifier Module using AlN Substrate)

  • 김승용;남충모
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.826-831
    • /
    • 2009
  • In this paper, a high power RF amplifier module using AlN substrate of high thermal conductivity has been proposed. This RF amplifier module has the advantage of compact size and effective heat dissipation for the packaging of high power chip. To fabricate the thru-hole and scribing line on AlN substrate, the key parameters of $CO_2$ laser were experimented. And then, microstrip lines and spiral planar inductors were fabricated on an AlN substrate using the thin-film process. The fabricated microstrip lines on the AlN substrate has an attenuation value of 0.1 dB/mm up to 10 GHz. The fabricated spiral planar inductor has a high quality factor, a maximum of about 62 at 1 GHz for a 5.65 nH inductor. Packaging of a RF power amplifier was implemented on an AlN substrate with thru-hole. From the measured results, the gain is 24 dB from 13 to 15 GHz and the output power is 33.65 dBm(2.3 W).

Graphene, Cu와 Ag 나노 파우더를 이용한 열전도재의 방열 특성에 관한 연구 (A study on the heat dissipation characteristic of thermal interface materials with Graphene, Cu and Ag nano powders)

  • 박상혁;임성훈;김현지;노정필;허선철
    • 한국산업융합학회 논문집
    • /
    • 제22권6호
    • /
    • pp.767-773
    • /
    • 2019
  • The thermal diffusion performance of the electronic device is a factor for evaluating the stability of the electronic device. Therefore, many of research have been conducted to improve the thermal characteristics of thermal interface materials, which are materials for thermal diffusion of electronic products. In this study, nano thermal grease was prepared by blending graphene, silver and copper nano powders into a thermal grease, a type of thermal interface materials, and the heat transfer rate was measured and compared for the purpose of investigating the improved thermal properties. As a result, the thermal properties were good in the order of graphene, silver and copper, which is thought to be due to the different thermal properties of the nano powder itself.

Numerical study on tensioned membrane structures under impact load

  • Zhang, Yingying;Zhao, Yushuai;Zhang, Mingyue;Zhou, Yi;Zhang, Qilin
    • Structural Engineering and Mechanics
    • /
    • 제71권2호
    • /
    • pp.109-118
    • /
    • 2019
  • This paper presents the numerical simulation of membrane structure under impact load. Firstly, the numerical simulation model is validated by comparing with the test in Hao's research. Then, the effects of the shape of the projectile, the membrane prestress and the initial impact speed, are investigated for studying the dynamic response and failure mechanism, based on the membrane displacement, projectile acceleration and kinetic energy. Finally, the results show that the initial speed and the punch shape are related with the loss of kinetic energy of projectiles. Meanwhile, the membrane prestress is an important factor that affects the energy dissipation capacity and the impact resistance of membrane structures.

Cyclic loading test of abnormal joints in SRC frame-bent main building structure

  • Wang, Bo;Cao, Guorong;Yang, Ke;Dai, Huijuan;Qin, Chaogang
    • Earthquakes and Structures
    • /
    • 제20권4호
    • /
    • pp.417-430
    • /
    • 2021
  • Due to functional requirements, SRC column-RC beam abnormal joints with characteristics of strong beam weak column, variable column section, unequal beam height and staggered height exist in the Steel reinforced concrete (SRC) frame-bent main building structure of thermal power plant (TPP). This paper presents the experimental results of these abnormal joints through cyclic loading tests on five specimens with scaling factor of 1/5. The staggered height and whether adding H-shaped steel in beam or not were changing parameters of specimens. The failure patterns, bearing capacity, energy dissipation and ductile performance were analyzed. In addition, the stress mechanism of the abnormal joint was discussed based on the diagonal strut model. The research results showed that the abnormal exterior joints occurred shear failure and column end hinge flexural failure; reducing beam height through adding H-shaped steel in the beam of abnormal exterior joint could improve the crack resistance and ductility; the abnormal interior joints with different staggered heights occurred column ends flexural failure; the joint with larger staggered height had the higher bearing capacity and stiffness, but lower ductility. The concrete compression strut mechanism is still applicable to the abnormal joints in TPP, but it is affected by the abnormal characteristics.