• 제목/요약/키워드: dissipation

검색결과 3,468건 처리시간 0.036초

유입변압기 오일필터링에 따른 유전정접 변화사례 고찰 (Example study of the dissipation factor change according to the oil filtering in large oil-filled transformer)

  • 공태식;김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2035_2036
    • /
    • 2009
  • This paper is purpose to understand the dissipation factor properties of the oil-filled large transformer according to the oil filtering. In order to know the insulation characteristic change by insulating oil filtering, we carried out the insulation diagnostic test for the same transformer before oil filtering and after. The insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, Especially we took notice of dissipation factor change, we analyzed and made a comparison of the two cases test result.

  • PDF

절연유의 열열화에 따른 Tan $\delta$와 수분의 변화에 의한 변압기의 예방진단 연구 (Study on Diagnosis for Transformers by Tan $\delta$ and Moisture of Insulation Oil According to Thermal Aging)

  • 황보승;한민구;곽희로;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.241-245
    • /
    • 1988
  • This paper reports the experiments regarding to diagnosis techniques for power transformers by measuring dissipation factor and moisture contents of mineral oils. Thermal aging environments of mineral oils were varied by the specially designed systems. Thermal aging of elevated temperature of $90^{\circ}C$ was performed for about 240 and 460 hours, respectively. Dissipation factor, permittivity, and water content were measured. Our test samples were not exposed to air. Dissipation factor increased while permittivity did not change. The level of dissipation factor determining the insulating quality of mineral oil was compared with the previous results of resistivity and several correction factor.

  • PDF

Effects of some factors on the thermal-dissipation characteristics of high-power LED packages

  • Ji, Peng Fei;Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2012
  • Decreasing the thermal resistance is the critical issue for high-brightness light-emitting diodes. In this paper, the effects of some design factors, such as chip size (24 and 35 mil), substrate material (AlN and high-temperature co-fired ceramic), and die-attach material (Ag epoxy and PbSn solder), on the thermal-dissipation characteristics were investigated. Using the thermal transient method, the temperature sensitivity parameter, $R_{th}$ (thermal resistance), and junction temperature were estimated. The 35-mil chip showed better thermal dissipation, leading to lower thermal resistance and lower junction temperature, owing to its smaller heat source density compared with that of the 24-mil chip. By adopting an AlN substrate and a PbSn solder, which have higher thermal conductivity, the thermal resistance of the 24-mil chip can be decreased and can be made the same as that of the 35-mil chip.

DSP를 위한 새로운 저전력 상위 레벨 합성 (A New Low Power High Level Synthesis for DSP)

  • 한태희;김영숙;인치호;김희석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.101-104
    • /
    • 2002
  • This paper propose that is algorithm of power dissipation reduction in the high level synthesis design for DSP(Digital Signal Processor), as the portable terminal system recently demand high power dissipation. This paper obtain effect of power dissipation reduction and switching activity that increase correlation of operands as input data of function unit. The algorithm search loop or repeatedly data to the input operands of function unit. That can be reduce the power dissipation using the new low power high level synthesis algorithm. In this Paper, scheduling operation search same nodes from input DFG(Data Flow Graph) with correlation coefficient of first input node and among nodes. Function units consist a multiplier, an adder and a register. The power estimation method is added switching activity for each bits of nodes. The power estimation have good efficient using proposed algorithm. This paper result obtain more Power reduction of fifty percents after using a new low power algorithm in a function unit as multiplier.

  • PDF

반실험적 열소산 방법을 이용한 위성용 전장품 열해석 (A SATELLITE ELECTRONIC EQUIPMENT THERMAL ANALYSIS USING SEMI-EMPERICAL HEAT DISSIPATION METHOD)

  • 김정훈;전형열;양군호
    • 한국전산유체공학회지
    • /
    • 제11권2호
    • /
    • pp.32-39
    • /
    • 2006
  • A heat dissipation modeling method of EEE parts is developed for thermal design and analysis of an satellite electronic equipment. The power consumption measurement value of each functional breadboard is used for the heat dissipation modeling method. For the purpose of conduction heat transfer modeling of EEE parts, surface heat model using very thin ignorable thermal plates is considered instead of conventional lumped capacity nodes. These modeling methods are applied to the thermal design and analysis of CTU EM and EQM and verified by thermal cycling and vacuum tests.

에너지 소산능력을 고려한 전단벽의 내진설계 (Seismic Design Method for Structural Walls Based on Energy Dissipation Capacity)

  • 박홍근;엄태성;정연희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.247-257
    • /
    • 2002
  • Recently, performance-based analysis/design methods such as the capacity spectrum method and the direct displacement-based design method were developed. In these methods, the estimation of energy dissipation capacity due to inelastic behavior of RC structures depends on empirical equations which are not sufficiently accurate. On the other hand, in a recent study, a simplified method for evaluating energy dissipation capacity was developed. In the present study, based on the evaluation method, a new seismic design method for flexure-dominated RC walls is developed. In determination of seismic earthquake load, the proposed design method can address variation of the energy dissipation capacity with design parameters such as dimensions and shapes of cross-sections, axial force, and reinforcement ratio and arrangement. The proposed design method is compared with the current performance-based design methods and the applicability of the proposed method is disscussed.

  • PDF

400kW급 IGBT 인버터용 방열 시스템 설계 (Design of a Heat Dissipation System for the 400kW IGBT Inverter)

  • 이진우
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.350-355
    • /
    • 2004
  • 본 논문에서는 열원인 전력용 반도체 소자와 방열판 및 팬으로 구성된 강제 냉각방식 방열 시스템을 먼저 해석 가능한 요소로 나눈 후 각 요소에 대한 해석적이거나 실험적인 설계 식을 제시하고 이를 적용한 설계 방법을 제안하였다. 제안한 방법으로 400kW급 IGBT 인버터용 강제 냉각방식 방열 시스템을 설계하고 제작하였다. 실험결과는 설계 온도가 실험치에 대해 10[%] 오차 범위 내에서 잘 일치함을 검증하여 제안한 해석적인 정상상태 설계방법의 타당성을 보였다.

열경화성수지 복합재료의 경화정도의 측정에 관한 연구 (Measurement of the Degree of Cure of Thermosetting Resin Matrix Composite Materials)

  • 김진수;이대길
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2154-2164
    • /
    • 1995
  • In this study, a dielectric cure monitoring system which consists of an electric circuit, a sensor and a personal computer was developed to on-line monitor the dielectric properties of carbon fiber epoxy composite materials. Also, the kinetic model of carbon fiber epoxy composite materials was developed by curve fitting of differential scanning calorimetry data. The start and end points of cure and the relationship between the dissipation factor and the degree of cure were obtained by comparing the dissipation factor from the dielectric properties with the degree of cure from the DSC data. The relationship between the dissipation factor and the degree of cure was tested under various temperature profiles.

파랑에 의한 항내진동의 제어에 관한 실험적 연구 (Eaperimental Study on the Control of Harbor Oscillation due to Water Wave)

  • 최한규;이선용
    • 산업기술연구
    • /
    • 제14권
    • /
    • pp.101-107
    • /
    • 1994
  • This study is to investigate harbor oscillation phenomenon according to combination of the wall structures by model experiment in a three dimensional wave basin. Six different types of wall combination were chosen through combination of erect wall, erect dissipation block, and sand beach, wave height at selected points in the harbor were measured by electronic wave gage. Test results show that the wall structure composed solely of erect walls showed generally highest harbor oscillation. Since natural beach shows lower reflection than erect dissipation block do, we thought it would be more efficient to use natural beach for improved harbor oscillation. The result showed, however, that the erect dissipation block are more efficient than natural beach to attain less harbor oscillation. The reason seens that the erect dissipation blocks have better capability to control breaking wave on the surface of the structure.

  • PDF

피에조콘 소산결과와 압축지수의 상관관계 (Correlation of Piezocone Dissipation Results and Compression Index)

  • 박영환;강병준;이준환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1204-1211
    • /
    • 2008
  • Compression index is one of the important characteristic numbers in soft soil engineering. Since 1940's, many researchers have suggested various practical solutions to define the compression index of clay using other soil properties. But, these results are only can give us an outline of soft soil behavior. In this study, the relationships between pore water pressure dissipation test results and compression index were suggested using comparison results of both tests. This relationships are based on basic concept of consolidation phenomena, essential difference between pore water pressure dissipation test and consolidation test, and disagreements between theoretical time factor and real time factor. To identify proportional factor of proposed equation, Geotechnical investigation results of Kwang-Yang(KY) site and Busan New Port(BN) site were used. The proportional factor was 0.0031 from 20 to 50% of consolidation rate where correlation parameter($R^2$) is 0.9051.